WISI DY 0908 Pro Switch Multiswitch Instruction Manual

June 5, 2024
WISI

WISI logo Operating manual
WISI PRO SWITCH

DY 0908 / DY 0916
Multiswitch 9 in x, cascade & stand aloneWISI DY 0908 Pro Switch
Multiswitch

  • Cascadable multiswitch for the distribution of eight satellite polarisations and terrestrial signals
  • Useable as a stand-alone device (DG 55 power supply required)
  • Stand-by function with connected power supply, optional permanent operation
  • Passive terrestrial path to distribute DVB-T/T2, DAB and FM without an additional amplifier
  • Integrated SAT amplifier for low insertion loss
  • Pre-emphasis to compensate the cable loss at high frequencies
  • High screening efficiency according to Class A
  • Stackable chassis for space-saving installation of various devices
  • Color-coded inputs and outputs

Important Notes:

Please check the coaxial cables regarding the short circuit before starting!
The mounting ground should be:

  • flame retardant
  • dust-free
  • protected against humidity
  • not under direct impact of sunlight
  • not adjacent to heating sources

Please check the input level of the SAT-lines: They should be nearly equal. All installations and fixings of components should only be executed by skilled people when the units are disconnected from the power source. Short-circuits have to be avoided. The European and national standards and regulations for the guarantee of electrical security have to be considered as well as the national permissions and legal regulations for broadcast receiving systems!
A ground connection must be installed at the device (Ground connector) as well as the satellite dish with at least 4 mm² cables
Grounding and Potential Equalization Pursuant to EN 50 083-1 the satellite antenna system must comply with safety requirements, i.e., grounding and potential equalization.

Application:

This multiswitch is used for the distribution of 8 SAT-IF-Polarizations (e.g. ASTRA and EUTELSAT) from two QUATTRO LNBs and terrestrial signals (active path). The selection of the IF-polarization is realized by the control signal 14/18 V (Vertical/Horizontal), 0/22 kHz (Low-, High-Band) and DiSEqC 2.0 by the connected receivers. The DY types can be powered by the external power supply unit DG 55 or through SAT–trunk lines from connected multi switches or amplifiers (please consider total current consumption). DC-blocks has to be considered to avoid power conflicts.  Not used cascade outputs has to be equipped withDC-blocked terminating 75 Ohm resistors.

Application example:

Specifications

SAT-IF trunk DY 0908 DY 0916
Inputs SAT 8 St./pcs.
Outputs SAT 8 St./pcs.
Frequency range SAT 950…2150 MHz
Through loss SAT 1,1…3 dB 1,6…4,5 dB
Decoupling SAT – SAT 40 dB typ.
Return loss SAT >10 dB

Terrestrial trunk

Inputs TERR 1 St./pacs.
Outputs TERR 1 St./pcs.
Frequency range TERR 5…862 MHz
Through loss TERR 3,5…4,2 dB (±1 dB)
Isolation TERR – SAT 40 dB typ.
Return loss TERR >15 dB

Subscriber outputs

Outputs 8 St./pcs. 16 St./pcs.
Frequency range 5…2150 MHz
TERR type passive
Insertion TERR (5…862 MHz) 24 dB (±3 dB)

Insertion loss SAT- 950 MHz
– 1350 MHz
– 2400 MHz| 3 dB
-0,5 dB
-2,2 dB|
Max. output level subscriber SAT (full band)| 90 dBµV|
Max. output level subscriber TERR| 81 dBµV|
Return loss subscriber SAT & TERR| >10 dB/>14 dB|
Control signal| 14/18 V, 0/22 kHz, DiSEqC 2.0|
Current consumption from the receiver| 70 mA| 50 mA

General data

Power indicator| LED|
---|---|---
Operating voltage| 10…19 V DC|
Power consumption max.| <0,2 W|
Screening factor| Class A, according to EN 50083-2|
 Impedance| 75 Ω|
Operating temperature range| -20…+50 °C|
Weight| 0,52 kg| 0,7 kg
Dimensions (width x height x depth)| 206x140x32 mm| 206x206x32 mm

WISI Communications GmbH & Co. KG
Inland: Phone +49 7233-66-0 Fax -320
Export: Phone +49 7233-66-0 Fax -350
Email: [email protected] 
wisigroup.com 
Technical Modifications reserved. WISI cannot be held liable for any printing error. / 11.17

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WISI User Manuals

Related Manuals