Instruction Manual
Pro Switch Plug-in Power Supply
- Operating voltage 230 V AC
- Output power 13 V DC
- Output current 2.3 A short circuit proof
Safety and warning notes
Please read these user instructions before using the plug-in.
This switch mode plug-in changes mains alternating current to touch-safe low
voltage and may be used only under the technical data listed below.
The switch mode plug-in is only designed for indoor use and should not come
into contact with water or dust. To prevent overheating the power supply
should not be covered when it is in use. Vibrations and special environmental
factors on the device are inadmissible.
The main socket should be easily accessible. In the event of an operational
error, the plug must be immediately removed from the socket.
The power supply is started up when the plug is inserted into the socket. To
turn off the power supply, the plug must be removed from the socket. Never
pull at the cable.
The power supply contains dangerous voltages and the cover should not be
removed.
All service or maintenance work should be carried out by qualified personnel
who can get assistance by contacting the manufacturer’s agent. With visible
damages to the device do not use this anymore.
An internal fuse protects the power supply against short circuiting in the
primary circuit. In the event that the fuse needs to be replaced, the same
type with the same breaking
characteristic and size of fuse should always be used.
The power supply is double-insulated (insulation class II) and needs no earth
connector.
The power supply is provided with a DC cable and exclusively for powering of
multi switches from the WISI Communications Company. One end of the DC cable
is compressed with a special F-connector for screwing. A good assembly at the
multi-switch prevents an unintended interruption of the DC power. The DC
connector is to be connected to the input DC port of the multi-switch
according to the instructions of the manual of the multi-switch.
Therefore the plug-in with the multi-switch forms a unit.
This switch mode plug-in has a plastic casing and shouldn’t contact with oils,
grease, etc., as most types of plastic can be broken down by chemicals and
solvents.
The Plug-in power supply is designated for the permanent operation of
satellite reception systems. For the use with WISI Pro switch multi switches
DY xxxx
PLEASE KEEP THIS INSTRUCTION IN A SECURE PLACE!
Technical data
F-plug | 1 Stk. / 1 pcs. |
---|---|
Input voltage | 100…240 V AC (50/60 Hz) |
Operating range | 90…264 V AC (50/60 Hz) |
Output voltage | 13 V DC |
Max. load current | 2,3 A |
Max. output power | <30 W |
Average operational efficiency | 86,9 % |
Low load efficiency (10%) | 76,2 % |
Max. humidity, noncondensing | 90% |
Safety class system | II |
Protection class system EN 60529 (DIN 40050) | IP 41 |
Electrical safety standard | EN 60065, EN 60950 |
EMC | EN 50083-2 |
Operating temperature | -20…+40 °C |
Storage temperature | -20…+80 °C |
Dimensions (LxWxH) | 72,2 x 42,2 x 68,2 mm |
Article number | 76574 |
Information
EU regulations for the disposal of old electrical appliances by private
households
In order to avoid hazards to health and the environment, EU legislation
specifies that affected products – identified by a crossed-out garbage bin on
the product or its packing materials – may not be disposed of together with
residual waste. You are responsible for ensuring that the appliance to be
discarded is delivered to a location prepared to receive electrical appliances
for the purpose of disposal or recycling (such as collection points for such
products). Further information on the disposal of electrical appliances can be
obtained from your local authorities, from the collection points, or from your
local electrical appliance dealer.
WISI Communications GmbH & Co. KG
Empfangs- und Verteiltechnik
Wilhelm-Sihn-Strasse 5-7
75223 Niefern-Öschelbronn
Germany
HRA 700359
Inland: Phone +49 7233-66-0 Fax -320
Export: Phone +49 7233-66-0 Fax -350
Email: info@wisi.de
Technical Modifications reserved. WISI cannot be held liable for any printing
error./03.20
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>