WISI DY 70 Pro Switch Plug-in Power Supply Instruction Manual

June 5, 2024
WISI

DY 70 Pro Switch Plug-in Power Supply
Instruction Manual

Pro Switch Plug-in Power Supply

  • Operating voltage 230 V AC
  • Output power 13 V DC
  • Output current 2.3 A short circuit proof

Safety and warning notes

Please read these user instructions before using the plug-in.
This switch mode plug-in changes mains alternating current to touch-safe low voltage and may be used only under the technical data listed below.
The switch mode plug-in is only designed for indoor use and should not come into contact with water or dust. To prevent overheating the power supply should not be covered when it is in use. Vibrations and special environmental factors on the device are inadmissible.
The main socket should be easily accessible. In the event of an operational error, the plug must be immediately removed from the socket.
The power supply is started up when the plug is inserted into the socket. To turn off the power supply, the plug must be removed from the socket. Never pull at the cable.
The power supply contains dangerous voltages and the cover should not be removed.
All service or maintenance work should be carried out by qualified personnel who can get assistance by contacting the manufacturer’s agent. With visible damages to the device do not use this anymore.
An internal fuse protects the power supply against short circuiting in the primary circuit. In the event that the fuse needs to be replaced, the same type with the same breaking
characteristic and size of fuse should always be used.
Icon The power supply is double-insulated (insulation class II) and needs no earth connector.
The power supply is provided with a DC cable and exclusively for powering of multi switches from the WISI Communications Company. One end of the DC cable is compressed with a special F-connector for screwing. A good assembly at the multi-switch prevents an unintended interruption of the DC power. The DC connector is to be connected to the input DC port of the multi-switch according to the instructions of the manual of the multi-switch.
Therefore the plug-in with the multi-switch forms a unit.
This switch mode plug-in has a plastic casing and shouldn’t contact with oils, grease, etc., as most types of plastic can be broken down by chemicals and solvents.
The Plug-in power supply is designated for the permanent operation of satellite reception systems. For the use with WISI Pro switch multi switches DY xxxx
PLEASE KEEP THIS INSTRUCTION IN A SECURE PLACE!

Technical data

F-plug 1 Stk. / 1 pcs.
Input voltage 100…240 V AC (50/60 Hz)
Operating range 90…264 V AC (50/60 Hz)
Output voltage 13 V DC
Max. load current 2,3 A
Max. output power <30 W
Average operational efficiency 86,9 %
Low load efficiency (10%) 76,2 %
Max. humidity, noncondensing 90%
Safety class system II
Protection class system EN 60529 (DIN 40050) IP 41
Electrical safety standard EN 60065, EN 60950
EMC EN 50083-2
Operating temperature -20…+40 °C
Storage temperature -20…+80  °C
Dimensions (LxWxH) 72,2 x 42,2 x 68,2 mm
Article number 76574

Information

EU regulations for the disposal of old electrical appliances by private households
In order to avoid hazards to health and the environment, EU legislation specifies that affected products – identified by a crossed-out garbage bin on the product or its packing materials – may not be disposed of together with residual waste. You are responsible for ensuring that the appliance to be discarded is delivered to a location prepared to receive electrical appliances for the purpose of disposal or recycling (such as collection points for such products). Further information on the disposal of electrical appliances can be obtained from your local authorities, from the collection points, or from your local electrical appliance dealer.

WISI Communications GmbH & Co. KG
Empfangs- und Verteiltechnik
Wilhelm-Sihn-Strasse 5-7
75223 Niefern-Öschelbronn
Germany
HRA 700359
Inland: Phone +49 7233-66-0 Fax -320
Export: Phone +49 7233-66-0 Fax -350
Email: info@wisi.de
Technical Modifications reserved. WISI cannot be held liable for any printing error./03.20