Jandy H0751300 TruDose Chemical Controller Instruction Manual

June 5, 2024
Jandy

H0751300 TruDose Chemical Controller

INSTALLATION AND OPERATION MANUAL
ENGLISH | FRANÇAIS | ESPAÑOL
pH 7.2-7.6 ORP 600-800 mV
TruDoseTM Chemical Controller
WARNING
FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. DO NOT MODIFY THIS EQUIPMENT. ATTENTION INSTALLER – This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/ operator of this equipment.
WARNING Periodically use an independent pH and Chlorine test kit to verify safe pH and chlorine levels. If the pH, Oxidation Reduction Potential (ORP) or Flow Cell sensors are damaged, dirty, contaminated, or otherwise malfunctioning; inaccurate results may be reported to the monitoring system resulting in improper water chemistry that may result in property damager, personal injury, or death.

H0751300_REVF

Page 2

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Table of Contents

Section 1. Important Safety Instructions ……. 3 1.1 Safety Instructions………………………………………. 3
Section 2. Getting Started………………………….. 7 2.1 System Components …………………………………… 7 2.2 Specifications …………………………………………….. 9 2.3 Controller Panel Descriptions……………………….. 9 2.4 Connecting the TruDose Chemical Controller
to an Optional Jandy Saltwater Chlorinator…… 10
Section 3. Installation………………………………. 12 3.1 Setup ………………………………………………………. 12 3.2 Tools ……………………………………………………….. 12 3.3 Power Supply …………………………………………… 12 3.4 Controller Installation…………………………………. 12 3.5 pH and ORP Sensors Installation………………… 12 3.6 Chemical Pump Installation………………………… 13 3.7 Bonding …………………………………………………… 15
Section 4. Startup and Shutdown …………….. 16 4.1 Water Chemistry……………………………………….. 16 4.2 Startup…………………………………………………….. 16 4.3 Shutdown ………………………………………………… 16 4.4 Modes and Adjustments …………………………….. 16

Section 5. Maintenance……………………………. 19 5.1 Winterizing (extended shutdowns or colder
climates). …………………………………………………. 19 5.2 Cleaning the sensor tips…………………………….. 19 5.3 Checking the pH Sensor ……………………………. 19 5.4 Checking the ORP Sensor …………………………. 19
Section 6. Chemical Pump Tube Replacement Procedure……………………………….. 20
6.1 Preparation………………………………………………. 20 6.2 Remove Tube …………………………………………… 20 6.3 Install New Tube……………………………………….. 21
Section 7. General Troubleshooting …………. 22
Section 8. Chemical Pump Tube Troubleshooting ……………………… 24

FCC Regulatory Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation/
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

ENGLISH

Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

Page 3

1.1 Safety Instructions
This device is for use with single-body swimming pool applications only. Not for use with dual-body pool and spa applications, or stand-alone spas. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
DANGER
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS EQUIPMENT IS NOT INSTALLED AND OPERATED CORRECTLY. INSTALLERS, POOL OPERATERS AND POOL OWNERS MUST READ ALL WARNINGS, CAUTIONS, AND INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
WARNING
BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF THE WATER.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets. Suction outlet (drain) assemblies and their covers must be certified to the latest published edition of ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
WARNING
Working with pool chemicals can be dangerous, always wear rubber gloves and eye protection. Always add acid to water, do not add water to acid. Always work in a well-ventilated area. Splashing or spilling acid can cause severe personal injury and/or property damage. Always follow all chemical manufacturer’s warnings, cautions, and handling instructions. When mixing, remember to always add acid to water.

WARNING DO NOT MIX SODIUM HYPOCHLORITE AND MURIATIC ACID.

WARNING
When mixing acid and water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID. Read and follow all the chemical manufacturer’s instructions thoroughly.
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
Due to the potential risk of fire, electric shock, or injuries to persons, Jandy equipment must be installed in accordance with the National Electrical Code® (NEC®), NFPA 70, or the Canadian Electrical Code (CEC) in Canada, all local electrical and safety codes, and the Occupational Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169, or from your local government inspection agency. Installation and operation of this equipment must be in accordance with Federal, State, and local building and health codes.

WARNING
DANGER ­ Risk of injury. a) Replace damaged cord immediately. b) Do not bury cord. c) Connect to a grounded, grounding type receptacle only.

Page 4

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 °C (98.6 °F). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of hyperthermia include: · Unawareness of impending danger · Failure to perceive heat · Failure to recognize the need to exit spa · Physical inability to exit spa · Fetal damage in pregnant women · Unconsciousness resulting in a danger of drowning
WARNING
To Reduce the Risk of Injury · The water in a spa should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C
(104°F) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. · Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38°C (100°F). · Before entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies. · The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with the possibility of drowning. · Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa. · Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
WARNING · People with infectious diseases should not use a spa or hot tub. · To avoid injury, exercise care when entering or exiting the spa or hot tub. · Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and
possible drowning. · Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub. · Water temperature in excess of 38°C (100°F) may be injurious to your health. · Before entering a spa or hot tub measure the water temperature with an accurate thermometer. · Do not use a spa or hot tub immediately following strenuous exercise. · Prolonged immersion in a spa or hot tub may be injurious to your health. · Do not permit any electric appliance (such as a light, telephone, radio, or television) within 1.5 m (5 ft.) of
a spa or hot tub. · The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. (For all permanently installed equipment intended for use on 15 or 20 ampere, 120 through 240 volt, single phase branch circuits). Connect only to a branch circuit that is protected by a ground-fault circuit-interrupter protection for personnel (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock. Do not use the device. Disconnect the device and have the problem corrected by a qualified service representative before using.
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THIS EQUIPMENT. Always disconnect power at the circuit breaker before servicing. Failure to do so may result in serious injury or death.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

ENGLISH

Page 5

WARNING
This device is for use with single-body swimming pool applications only. Not for use with dual-body pool and spa applications, or stand-alone spas. Use of this product with dual-body pool and spa applications or stand-alone spas may cause severe injury, property damage, and void the warranty.

WARNING Incorrectly installed equipment may fail, causing severe injury, property damage, and may void the warranty. DO NOT MODIFY THIS EQUIPMENT.
WARNING Do not connect the system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI.
WARNING To minimize the risk of severe injury or death, this equipment should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. Zodiac® pool equipment is pressure tested at the factory. However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS: · Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and
secured before testing.
· RELEASE ALL AIR in the system before testing.
· Water pressure for test must NOT EXCEED 35 PSI.
· Water temperature for test must NOT EXCEED 100°F (38°C).
· Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult equipment manufacturer.

WARNING Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
CAUTION Do not install within an outer enclosure or beneath the skirt of a hot tub.
CAUTION In order to avoid premature failure or damage to the equipment, protect the equipment from direct water exposure from sprinklers, water runoff from rooftops and drainage, etc. Failure to comply may cause equipment failure, and may void the warranty.
WARNING Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.

Page 6

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

DANGER
READ THE FOLLOWING BEFORE HANDLING AND WORKING WITH MURIATIC ACID (ALSO KNOWN AS HYDROCHLORIC ACID) AND CHLORINE (SODIUM HYDROCHLORITE) MURIATIC ACID AND CHLORINE (LIQUID AND MIST) CAN CAUSE SEVERE BURNS TO SKIN, MOUTH AND EYES. MAY BE FATAL IF SWALLOWED OR INHALED. INHALATION CAN CAUSE SEVERE LUNG DAMAGE. IMPORTANT! CHLORINE CONTAINER MIXING CHEMICALS WITH CHLORINE OR CHLORINE RESIDUE IN CONTAINER CAN CREATE A DEADLY GAS OR AN EXPLOSION.
WARNING
INHALATION Inhalation of vapors can cause coughing, inflammation of the nose, throat and upper respiratory tract and death. In case of inhalation, move to an area of fresh air immediately.
INGESTION Swallowing can be fatal. Contact local poison control center or physician immediately. Give large amounts of water or milk. Allow person to vomit. If vomiting occurs, keep head lower than hips to avoid aspiration. If person is unconcious, turn their head to the side. Seek immediate medical attention.
STORAGE Install and store container and acid in a dry, ventilated place protected from excess heat and direct sunlight. Should be stored at a temperature below 80° F (27° C). Be sure drainage is located away from building and equipment.
SKIN CONTACT Wash skin with soap and water for at least 20 minutes and remove contaminated clothing and shoes. Contaminated clothes should be thoroughly cleaned before re-use.
EYE CONTACT Flush eyes immediately with waterr for at least 20 minutes. Seek immediate medical attention.
PERSONAL PROTECTION
VENTILATION Use container outside and in a well-ventilated area.
EYE PROTECTION Use splash-resistant safety goggles.
CLOTHING Wear chemical-resistant clothing when handling or working with acid and chlorine.
GLOVES Wear chemical-resistant gloves when handling or working with acid and chlorine.
DISPOSAL Because of its corrosive nature, muriatic acid is a hazardous waste when spilled or discarded. Dispose of used acid at an approved hazardous waste facility or at your municipal household hazardous waste collection facility. Small spills of acid may be neutralized using baking soda. Carefully pour the baking soda onto the spilled material until fizzing has stops, then mop or scoop up the residue. Leave cleanup of large spills to the experts: call your local fire department or hazardous materials spill team.

SAVE THESE INSTRUCTIONS

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Section 2. Getting Started
This manual provides installation and basic operation instructions for the TruDose Chemical Controller.
Read the installation and operation instructions completely before proceeding with the installation. Keep this manual in a safe place for future reference.
2.1 System Components
2.1.1 TruDose Chemical Controller The TruDose Chemical Controller allows automatic monitoring and adjusting of pH and ORP (adjusting requires an optional saltwater chlorinator connected) levels through a simple, user- friendly interface, resulting in easier management of water balance in swimming pools.
It can be easily installed into your existing pool environment and equipment and monitors and displays the pH and ORP levels using LEDs and digital readouts on the front panel of the unit. In addition, four separate function buttons allow simple pushbutton control of these individual parameters:
· Mode – Auto (running), pH settings, ORP settings.
· Set level – pH or ORP level to be maintained.
· Dose Time – Dose time (seconds) for pH. Overfeed time (hours) for ORP.
· pH Cal – pH calibration for variation in pH sensors
The controller has a peristaltic pump that feeds liquid acid. The acid pump will turn on if the pH measured is higher than the setpoint defined by the user. When the ORP measured by the ORP sensor is lower than the setpoint defined by the user, the controller turns on the chlorination from the optional saltwater chlorinator to produce chlorine and reach the desired ORP. When the ORP reaches the setpoint, the chemical controller has the ability to turn off the chlorination from the saltwater chlorinator. The saltwater chlorinator is not provided with the TruDose chemical controller.
2.1.2 Flow Cell with Flow Switch The flow cell houses a flow switch and holds the pH and ORP sensors. These sensors connect to the chemical controller to monitor the pH and ORP levels in the water. The flow switch verifies that water is flowing during a feed cycle and sends the controller instructions to deactivate the feed if water is not flowing. Operation of this controller without a functioning flow switch may result in under-dosing or over-dosing of chemicals.

ENGLISH

Page 7

2.1.3 Other Components

· pH sensor – standard (use only part number R0894300)

· ORP Gold Sensor – standard (use only part number R0894400)

· Fittings – for tapping installation of flow cell input/ output

· In-line Filter – install prior to the flow cell to protect the flow switch and the pH and ORP sensors.

· Tubing – 25 feet of 3/8″ and 20 feet of 1/4″ for providing acid to and from the acid tank.

· pH Pump – including tubing and fittings – integrated peristaltic pump for pH-controlling acid.

· Mounting Board – ABS plastic with mounting holes and stainless hardware (18″ x 10″).

· 1/4″ NPT tap (included)

NOTE:

Using undiluted acid could lead to corrosion or overfeeding issues. Use muriatic acid only (not provided). Dilute the acid 4:1 following the safety recommendations of the chemical manufacturer, and use personal protective equipment. For example: For a 5 gallon tank, there would be 4 gallons of water and 1 gallon of muriatic acid.

TruDose R-kits

1

R0894300

2

R0894400

3

R0944100

4

R0944300

5

R0944400

6

R0944500

7

R0944600

8

R0944900

9

R0945000

10 R0945100 11 R0945200 12 R0945300 13 R0945400 14 R0961700 15 R0962100

PH SENSOR ORP SENSOR PCBA REPLACEMENT POWER CABLE CONTROLLER ONLY 1/4″ BLACK POLY TUBING (25 FOOT ROLL) 3/8″ BLACK POLY TUBING (28 FOOT ROLL) FLOW CELL W/ FLOW SWITCH, VLV, FTGS10 INLINE FILTER W/SCREEN & FTGS FLOW SWITCH SQUEEZE TUBES (2 PACK) PUMP ACCESSORY KIT PERISTALTIC ACID PUMP PUMP ROLLER ASSEMBLY TRUDOSE SWC CABLE 24 VDC

Page 8

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

Typical Installation
NOTE: All chemical must be injected downstream from the heater and flowcell.

GFCI-protected Watertight Outdoor
Outlet

ORP pH

pH 7.2-7.6 ORP 600-800 mV

Flow Cell

*NOTE: Mount power supply transformer 1ft (30 cm) above ground surface.
Pump

Filter

*See Note

Heater

From Pool

Check Valve

AquaPure Cell

Do

Not Cap

Pool Return

Figure 1. Typical hydraulic installation of a TruDose Chemical Controller

1 Water sample to the Flow Cell

2 Water return from the Flow Cell

3 Acid introduction

AquaPure® Control

PureLink Power Center

TruClear® XL

Center

1

OR

OR

Heater

Flow Cell TruDose Controller

3

Filter

Pump

pH 7.2-7.6 ORP 600-800 mV

2

Cell with Flow/Temp/Salinity Sensor

Pool Return

Figure 2. Flow Cell Connection – Top View

Pool Intake

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
2.2 Specifications

System Dimensions 8″ L x 10″ W x 6.5″ D

Electrical input/output

Input : 100 – 240 VAC ~ 50 / 60 Hz 0.6A
Output : 24V DC – 1000 mA 24W (Power supply provided)

pH Set Level

7.0 to 8.0

ORP set level

400 mV to 900 mV

pH dose timer

Off or timed cycle

Low Alert

pH 6.9, ORP 390mV

High Alert Readout Alerts (low or high) pH Overfeed Alarm ORP Overfeed Alarm

pH 8.1, ORP 910mV
Functional LED and numerical digital displays that alternates between pH and ORP (mV)
Red alert LEDs – solid
– Alert pH LED blinking – Er1 displayed on the LCD screen – Alert ORP LED blinking – Er2 displayed on the LCD screen

Peristaltic Pump for Acid

pH 7.2-7.6 ORP 600-800 mV

Controller Communication Digital Display Pushbutton LEDs

pH Sensor

Flow Switch

Power ORP Sensor

Salt Water Chlorinator
Control

Figure 3. Controller Connections

ENGLISH

Page 9

2.3 Controller Panel Descriptions

2.3.1 Digital displays and function LEDs
a. pH
The measured pH value is displayed on the LCD screen.

· pH alert (low or high) – solid red LED
· pH overfeed alarm – red LED blinking and “Er1” displayed on the LCD screen
· pH dose – running – flashing green LED
· pH dose – time off – solid green LED
b. ORP
The measured ORP value is displayed in millivolts (mV) and displayed on the LCD screen. (alternates with pH).

· ORP Alert (low or high) – solid red LED
· ORP overfeed alarm – red LED blinking and “Er2” displayed on the LCD screen
· ORP dose – timer on – flashing green LED
Mode – pushbutton adjustments
· Auto – red LED · pH settings – green LED · ORP settings – yellow LED · OFF mode – in standby, press and hold mode button
for 3 seconds to turn controller off.

· Flow – green LED · Set Level – pushbutton adjustments (up/down) · Dose time – pushbutton adjustments (up/down) · pH Cal – pushbutton adjustments (up/down) 2.3.2 Electrical Connections (peripherals) · AC power – 100-240 VAC, 50-60 Hz · Flow Switch – from flow cell · pH sensor (blue) – BNC connection · ORP sensor (red) – BNC connection

· Saltwater chlorinator control – 24VDC

Page 10

ENGLISH

2.4 Connecting the TruDose Chemical Controller to an Optional Jandy Saltwater Chlorinator

WARNING
Disconnect power to the TruDose before servicing by unpluging the power supply at the receptacle.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

2.4.1

Connecting the TruDose Chemical Controller to the Jandy AquaPure® Saltwater Chlorinator

The TruDose Chemical Controller is compatible with the Jandy AquaPure Saltwater Chlorinator. This includes the

power packs APUREM, FUSIONM and PURELINK.

When the TruDose ORP reading is lower than the setpoint, the 24VDC cable will command the saltwater chlorinator to turn on the chlorination. The chlorinator will start to produce chlorine. The chlorinator user interface will display the production rate of 0% to 100% chlorine output.
When the TruDose ORP reading is higher than the setpoint, the 24VDC cable will command the saltwater chlorinator to turn off the chlorination. The chlorinator will not produce chlorine, and the chlorinator user interface will display “EC” (external control) flashing. To connect the TruDose Chemical Controller to a Jandy saltwater chlorinator, you will need to connect the preinstalled 24VDC cable from the TruDose Chemical Controller to the Power Interface Board (PIB) in the saltwater chlorinator power pack. The ORP Jumper on the Saltwater Chlorinator power pack PIB board will need to be moved to Position 2. See Figure 6 for instructions how to move the ORP Jumper to Position 2 on the power pack PIB.
pH 7.2-7.6
ORP 600-800 mV

Figure 5. AquaPure® Power Center (APUREM)

CAUTION
Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage, severe injury or death.

The ORP Jumper as a default comes from the factory in Position 1.
1. Remove the ORP Jumper J14 from the board. 2. Move the ORP Jumper from the two bottom pins to
the two top pins. See Figure 6. 3. Connect the TruDose 24VDC cable to the dedicated
2-pin connector J15 on the AquaPure power center PIB. See Figure 6.
NOTE: The black wire must be connected to the right and the red to the left.

ORP Connector
J15 R0474300

Wires to the external ORP Controller
Black
Red

24VDC Cable
Figure 4. TruDose Controller 24VDC Connection

Shift Up
J2
ORP

Jumper

J2

J14

Chlorine Generator Power Interface Board
Figure 6. ORP Connection
4. The RS-485 connection can remain to provide AquaPure information, including salt concentration, status, and production % changes through the iAquaLink app.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

2.4.2

Connect the TruDose Chemical Controller to the Jandy TruClear® XL Saltwater Chlorinator

CAUTION
Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage, severe injury or death.

1. Punch out the left bottom hole (located in the low voltage section) in the bottom of the TruClear XL power pack.
2. Install the bushing that was provided with the
TruClear XL power pack into the punch-out hole.

ENGLISH

Page 11

6. Move down the ORP jumper on the TruClear XL power center Power Interface Board (PIB) from Position 1 (default) to Position 2.

24VDC Cable from TruDose Controller

Shift Down ORP Jumper J17

ORP Connector J16

Figure 9. TruClear XL Power Center PIB

24VDC Cable to TruDose

RS-485 Cable

Figure 7. TruClear XL Communication/Power Connection

3. Remove the connector with a flathead screwdriver that is on the end of the TruDose 24VDC cable.

NOTE:

The RS-485 connection must be removed to activate the ORP control through the TruClear XL system with info provided through the iAquaLink app.

Remove Connector from pre-installed 24VDC Cable

NOTE:

“EC” will be displayed on the saltwater chlorinator when the chlorination is OFF. Once the unit turns on, the chlorine generator will not respond to any changes during the first minute of operation. The unit may appear to be STUCK IN “EC” mode. Wait several minutes until the unit has warmed up to verify the chlorinator has responded to being turned on.

NOTE:

Multiple chlorine generators can be linked together to be controlled with one ORP controller without the use of external relays and transformers. Contact the factory for more information.

Position of ORP Jumper J14 / J17
POS 1 (default)
Will not control chlorinator properly
POS 2 (needed with TruDose)

24 VDC
Unit OFF displays EC on chlorinator Unit ON displays 0-100% on chlorinator

0 VDC
Unit ON displays 0-100% on chlorinator Unit OFF displays EC on chlorinator

Figure 8. TruDose 24VDC Cable
4. Insert the TruDose 24VDC cable through the newly installed punch-out hole and bushing in the bottom of the TruClear XL power pack.
5. Install the 2 pins of the TruDose 24VDC cable to the ORP connector J16 located on the TruClear XL power board. The top of the connector is removable to make installation easier.

J14 = location of the ORP jumper on the AquaPure board. Must move up to Position 2.
J15 = location of the ORP connector on the AquaPure board. Insert the 24VDC cable here.
J16 = location of the ORP connector on the TruClear XL board. Insert the 24VDC cable here.
J17 = location of the ORP jumper on the TruClear XL board. Must move down to Position 2.

Page 12

ENGLISH

Section 3. Installation

3.1 Setup
1. Turn off all peripheral equipment such as heaters and pumps.
2. Relieve pressure from the filtration system.
3.2 Tools
· Cordless drill · 1/4″ NPT Tap (provided) · 7/16″ drill bit · Masonry drill bit and anchors or other appropriate
fasteners. · 13/16″ wrench or channel-lock pliers
· Water-tight outlet cover for outdoor installations
3.3 Power Supply
· The TruDose Chemical Controller needs to be connected to a GFCI protected watertight outdoor outlet.
· Do not use extension cords. · The power supply must be installed at least 1 ft
(30cm) above the ground surface. Ensure the power supply is protected from direct water exposure from sprinklers, water runoff from rooftops and drainage.
ATTENTION
The controller must be powered only with the provided power supply, and connected to a dedicated GFCI protected electrical circuit, Class A GFCI in Canada. No other equipment, lights, appliances, or outlets may be connected to the controller circuit.

3.4 Controller Installation
3.4.1 Location
· Wall area with easy access · At least 5 feet (1.5 m) horizontally from the edge of
the pool and/or spa. In Canada, at least 3 meters (10 feet) horizontally from the edge of the pool and/or spa.
· Within 15 feet of GFCI power source
CAUTION
In order to avoid premature failure or damage to the controller, protect the controller from direct water exposure from sprinklers, water runoff from rooftops and drainage, etc. Failure to comply may cause controller failure, and may void the warranty.
· The TruDose Controller must be installed at least 2 feet (0.6 m) vertically off the ground surface. Ensure the controller is protected from direct water exposure from sprinklers, water runoff from rooftops and drainage.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.4.2 Mounting
NOTE: The controller and flow cell are factory mounted to the ABS board for your convenience.
1. Securely mount ABS mounting board with the chemical controller and flow cell on the wall.
2. Drill a 7/16″ hole and tap a 1/4″ NPT port to a location downstream from the filter and upstream from any heater or chemical introduction point. Install a tubing connector (included) and 3/8″ flex tubing to be connected to the left side flow cell port containing the flow switch. The in-line filter will also be installed in this line in an easily-accessible location.
NOTE: Verify that the in-line filter is installed with directional arrows pointing in the direction of the flow (towards flow cell).
3. Drill a 7/16″ hole and tap a 1/4″ NPT port to a location that is subject to vacuum or reduced pressure. Install a tubing connector (included) and 3/8″ flex tubing to be connected to the right side flow cell port.
NOTE: We recommend that this tubing connector be installed into the drain hole on the suction side of the pump for best performance.
4. Cut 3″-6″ length of 3/8″ flex tubing and insert into the flow cell’s sample stream port (center).
3.5 pH and ORP Sensors
Installation
NOTE: Carefully unpack the pH and ORP sensors and set aside in a clear area until ready to install into the flow cell.
1. Verify that the controller power is off. 2. Carefully remove the plastic protective container
from the sensors and store in a separate location for future re-use. 3. Loosen (do not remove) the top nut of the compression fittings at the top of the flow cell and carefully slide the glass end of each sensor (pH and ORP) into the compression fittings. Ensure that the tip is submerged into the water to within 1/2″ from the bottom of the flow cell. Hand tighten each nut fitting. Do not use any tools to tighten the compression fittings. 4. Electrical Connections · Verify that the controller is off.
· Connect the pH sensor connector (blue) to the left BNC connector on the bottom of the controller.
· Connect the ORP sensor (red) to the right BNC connector on the bottom of the controller.
· Plug power supply into the GFCI protected outlet (outdoor installations should have weather proof enclosures installed).
NOTE: Continue to monitor free chlorine with manual testing to ensure proper sanitation levels.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.6 Chemical Pump Installation
WARNING
CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines. Locate chemical feed pumps and chemical storage tanks in a safe and secure area.
3.6.1 Pump Accessory Checklist
· Three (3) 1/4″ connecting nuts
· Three (3) 1/4″ ferrules
· One (1) injection check valves
· One (1) 1/4″ weighted suction line stainers
· One (1) 20′ roll of 1/4″ black suction/discharge tubing
3.6.2 Chemical Pump Safety Warnings 1. Read all safety hazards before installing or
servicing the pumps. The pump is designed for installation and service by properly trained personnel. 2. Use all required personal protective equipment when working on or near a dosing pump. 3. Install the pump so that it can follow all national and local plumbing and electrical codes. 4. Use the proper product to treat swimming pool water systems and use only additives listed or approved for use. 5. Inspect tubes frequently for leakage, deterioration or wear. Schedule a regular pump tubing maintenance change to prevent damage to pumps and/or spillage. 6. Pumps are not recommended for installation in areas where leakage can cause personal injury or property damage.
Disassembled View of injection check valve

Duckbill
Flow direction of solution Discharge Line
Injection Check Valve

Disassembled view of nut and ferrule
Suction Line

ENGLISH

Page 13

DO NOT use teflon tape on pump or tube threads
DO NOT use pliers
Finger Tighten Nut
Discharge Line

Disassembled view of nut and ferrule
Ferrules Note: Beveled ends of ferrules face pump. Tubings should bottom into all fittings.
Suction Line

Figure 11. Install Suction Line to Pump Head

3.6.3 Suction Line to Pump Head
1. Uncoil the suction/discharge line. Use outside of solution tank as a guide to cut proper length of suction line, ensuring it will be 2-3″ above the bottom of solution tank.

NOTE:

Allow sufficient slack to avoid kinks and stress cracks. Always make a clean square cut to assure the suction line is burr free. Normal maintenance requires trimming.

NOTE: Suction lines that extend to the bottom of the tank can result in debris pickup leading to clogged injectors and possible tube failure.
2. Make connections by sliding the line(s) through connecting nuts and ferrules and finger tighten to the corresponding tube fittings.
3. Finger tighten nut to the threaded tube fitting while holding the tube fitting.
NOTE: Overtightening the ferrule and nut with a wrench may result in damaged fittings, crushed ferrules and air pick up.

NOTE: DO NOT use thread sealant tape on pump tube connections or tools to tighten connections.

3.6.4 Suction Weight to Suction Line 1. Drill a hole into the bung cap or solution tank lid.
Slide the tubing through and secure the weighted strainer to the line. 2. To attach the strainer, push the approximately 3.5″ of suction line through the cap on the strainer body. Pull tubing to make sure it is secure.
3. Suspend slightly above the tank bottom to reduce the chance of sediment pickup.
NOTE: DO NOT mix additives in the solution container. Follow recommended mixing procedures according to the manufacturer.

Figure 10. Chemical Pump Installation Diagram

Page 14

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

NOTE:

The injection point and fitting require periodic maintenance to clean any deposits or buildup. To allow quick access to the point of injection, we recommend the installation of shut-off valves.

Suction Line

DO NOT use teflon tape on pump or tube threads

3.5″ (9 cm)

Weighted

Suction Line

3″

Strainer

Trim injection fitting end

DO NOT use pliers

Figure 12. Install Suction Weight to Suction Line
3.6.5 Discharge Line to Pump Head and Injection Point
1. Make a secure finger tight connection on the discharge fitting of the pump head as instructed in the Install Suction Line Instruction section.
NOTE: DO NOT use thread sealant tape on pump tube connections or tools to tighten connections.
WARNING
HAZARDOUS PRESSURE: Shut off water or circulation and bleed system pressure.

Typical Point of Injection

Injection Valve

Do

Not Cap

Check Valve

Return Line

Figure 13. Install Discharge Line to Pump Head and Injection Point

NOTE: Locate a point of injection beyond all pumps and filters or as determined by the application.
2. A 1/4″ or 1/2″ female NPT (FNPT) connection is required for installing the injection fitting. If there is no FNPT fitting available, provide one by either tapping the pipe or installing an FNPT pipe tee fitting.
3. Wrap the male NPT (MNPT) end of the injection fitting with 2 or 3 turns of threading tape. If necessary, trim the injection fitting quill as required to inject product directly into the flow of water.
4. Hand tighten the injection fitting into the FNPT fitting.
5. Install connecting nut and ferrule to the pump discharge tubing. Insert discharge tubing into injection fitting until it reaches the base of the fitting.
6. Finger tighten the connecting nut to the fitting. 7. Turn the pump on and re-pressurize the system.
Observe the flow as actuated by the system and check all connections for leaks.
8. After a suitable amount of dosing time, perform test for desired readings. If necessary, fine tune the dosing levels.

NOTE:

Using undiluted acid could lead to corrosion or overfeeding issues. Use muriatic acid only (not provided). Dilute the acid 4:1 following the safety recommendations of the chemical manufacturer, and use personal protective equipment. For example: For a 5 gallon tank, there would be 4 gallons of water and 1 gallon of muriatic acid.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.7 Bonding
The National Electrical Code® (NEC® in the United States) or the Canadian Electrical Code (CEC in Canada) requires metal parts of electrical equipment associated with the pool water circulation and fixed metal parts within 5 ft of the pool wall in the USA, 10 ft for Canada, to be bonded to each other. Check your local codes to determine if the NEC or CEC and/or other local installation codes are enforced by the Authority Having Jurisdiction (AHJ in the United States) or the local competent authorities in Canada. A solid copper 8.37mm2 (8 AWG) wire is required, per the NEC and CEC (CEC requirement is 6 AWG), with the bonding must be accomplished by using a solid copper conductor, No. 8 AWG or larger. In Canada, No. 6 AWG or larger must be used. The TruDose Chemical Controller does not have any exposed metal parts requiring equipotential bonding, nor metal parts in contact with the water circulation system, and therefore does not require equipotential bonding connections.
National Electrical Code® (NEC®) requires bonding of the Pool Water. Where none of the bonded pool equipment, structures, or parts are in direct connection with the pool water; the pool water shall be in direct contact with an approved corrosion-resistant conductive surface that exposes not less than 5800 mm² (9 in²) of the surface area to the pool water at all times. The conductive surface shall be located where it is not exposed to physical damage or dislodgement during usual pool activities, and it shall be bonded in accordance with the bonding requirements of NEC Article 680. Refer to locally enforced codes for any additional bonding requirements.

ENGLISH

Page 15

Page 16

ENGLISH

Section 4. Startup and Shutdown

4.1 Water Chemistry
Start with Balanced Pool and Spa Water.
1. Use a pool chemistry test kit with fresh testing reagents to measure the pH, alkalinity, and calcium hardness of the pool water. Every pool is unique, and a pool service professional can help you determine the optimum chemistry for your pool.
The values below are the recommend pool water chemistry values according to ANSI/APSP/ICC-11 Standard for Water Quality in Public Pools and Spas.
Free chlorine level: POOL – Minimum 1 ppm, maximum 4 ppm. SPA – Minimum 2 ppm, maximum 5 ppm.
pH: 7.2 – 7.8
Total Alkalinity: 60 – 180 ppm
Calcium Hardness: POOL 150 – 1,000 ppm, SPA 100 800 ppm.
Total Dissolved Solids (TDS): Maximum 1500 ppm (not including sodium chloride)
Langelier Saturation Index (LSI): -0.3 to +0.5
IMPORTANT: EPA-registered pool and/or spa sanitizers shall be used in accordance with the product manufacturer’s EPA-accepted label for use and/or operation requirements.

4.2 Startup

1. Plug the controller into the power outlet. For outdoor installations, ensure the use of a watertight outlet cover.
2. Turn on the filter pump and verify the water flow through the flow cell by opening the sample port valve (center) and observing a steady stream of water. The right side valve may need to be partially closed to produce a steady stream.

NOTE:

Water should pass over the pH and ORP sensors for a minimum of 10 minutes to allow for accurate, stable readings of pH and ORP
levels from the pool.

3. Check for leaks and repair if necessary.

4. Manually adjust and balance the pool water to acceptable ranges using a test kit.

NOTE: Use a DPD based test kit to check the chlorine level.

5. Verify that the green Flow LED is illuminated. Both the pH and ORP dose outputs are disabled if there is no water flow.
6. Press the Mode pushbutton momentarily to place the controller into pH setting mode. The green pH setting LED will illuminate. Select the desired pH set level and dose time (seconds).
7. While still in pH setting mode, press the pH Cal pushbutton to calibrate the reading to the value observed through the manual testing of the water.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

NOTE: Always calibrate using water from the sample port of the flow cell.
8. Press the Mode pushbutton momentarily to place the controller in ORP setting mode. The yellow ORP setting LED will illuminate. Select the desired ORP set level.

NOTE:

If the pH level in the pool is at the desired set level and the chlorine/bromine level is at the desired PPM level in the pool, the ORP set level should be the same as the current ORP reading when in auto Mode.

4.3 Shutdown

NOTE

Each time the Mode pushbutton is momentarily pressed, the mode will cycle from auto to pH setting to ORP setting and then return to auto mode.

1. Press the Mode pushbutton momentarily to place the controller in pH setting mode. The green pH setting LED will illuminate and both the pH and ORP digital displays will show dashes.

2. Press and hold the Mode pushbutton for 2 seconds until both the pH and ORP displays read OFF.
3. The controller will turn off and the digital displays and function LEDs will go blank. The green Flow LED will be illuminated if water is flowing through the flow cell.

NOTE There is still power to the controller unless the power supply is unplugged.

4.4 Modes and Adjustments

4.4.1 Auto
This is normal operational mode. The controller allows full operation and monitoring of both pH and ORP (sanitizer) levels. No function pushbuttons are operational in this mode.

· The red function LED next to auto is illuminated.

· Digital display alternates the display between the pH and ORP readings.

4.4.2 pH Setting

NOTE

While in this mode, the green pH setting LED will illuminate, both the pH and ORP digital displays will show dashes and all auto functions will be disabled. When a function pushbutton is pressed, the digital display will show the
function.

a. Set Level
1. Default: 7.4 pH 2. Selectable range: 7.0 – 8.0 pH (in 0.1 increments)

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
b. Dose Timer
1. Default: Timed dose of 30 seconds pH pump energized and 5 minutes pH feed pump in delay (mixing time). In the timed dose cycle mode, the Dose LED will flash while dosing and illuminate steadily during the delay portion of the timed cycle.
2. Selectable range: OFF and Timed (10-900 seconds ON and 5 minutes OFF).
3. Make sure to separately check your pool’s total alkalinity (TA) regularly. Adding acid to your pool water will lower total alkalinity.
4. To avoid overfeeding issues, it is recommended to start the unit with the default settings (30 seconds). The dosing time can be increased if the device is not able to maintain the pH value at the desired value.
c. Overfeed Timer
The overfeed timer turns off dosing if the pH setpoint is not reached within a certain amount of time. This is a safety feature to avoid overdosing or to detect if the acid tank is empty. The timer settings are:
1. Preset: 60 timed cycles. The overfeed timer does not automatically reset. It must be reset by turning the controller off and then on or cycling the mode out of auto and back to auto.
2. The overfeed timer is interlocked with the dose timer selection.When the preset cycle limit is reached, the pH alert LED will flash and “Er1” will be displayed on the LCD screen. The pH dosing pump is stopped to avoid overfeeding acid into the pool.
When the preset cycle limit is reached, the pH alert LED will flash and “Er1” will be displayed on the LCD screen. The pH dosing pump is stopped to avoid overfeeding acid into the pool.
d. High Alert – Default: 8.1 pH
1. Display: pH alert LED on
e. Low Alert – Default: 6.9 pH
· Display: pH alert LED on
f. pH Cal
· Allows +/- 0.5 pH adjustment from the current reading.
4.4.3 ORP Setting
NOTE: While in this mode, the yellow ORP setting LED will illuminate, both the pH and ORP digital displays will show dashes and all auto functions will be disabled. When a function pushbutton is pressed, the digital display will show the function.

ENGLISH

Need Chlorine Production (ORP lower than Setpoint)

Flashing

Page 17
100%

Chlorine Production OFF (ORP higher than Setpoint)
Off
EC

Figure 14. TruDose / APUREM Interfaces

Need Chlorine Production (ORP lower than Setpoint)

Flashing

CHLORINATING 100%

Chlorine Production OFF (ORP higher than Setpoint)
Off

EXTERNAL CONTROL

Figure 15. TruDose / TruClear XL Interfaces
a. Set Level
1. Default: 700 mV 2. Selectable range: 400 mV to 900 mV (in 10 mV
increments).
b. Dosing Strategy
· Default: the controller will continuously energize the 24VDC relay controlling the saltwater chlorinator (not provided), via the ORP mode until the setpoint or the overfeed timer is reached.

Page 18

ENGLISH

c. Overfeed Timer
The ORP overfeed timer is a safety function turning off the dosing if the ORP setpoint is not reached under a certain amount of time.

· Avoid overdosing of chemicals in case of wrong / inconsistent ORP measurement for a long period of time.

· Detect saltwater chlorinator issues.
· Default: The ORP overfeed timer will turn on after 36 hours of chlorination without reaching the ORP setpoint.
· The ORP overfeed timer can be modified using the “Dose time” pushbutton in ORP mode. Default: 36 hours Selectable range: 12 hours to 96 hours of chlorination (12 hours increment).
Increase the Overfeed timer if the unit is not able to maintain the defined ORP setpoint and triggers the ORP overfeeding alert regularly.
· Display: The ORP LED is blinking in the auto mode and “Er2” is displayed on the LCD screen.

· The overfeed timer does not automatically reset. It must be reset by turning the controller off and then on or cycling the mode out of auto and back to auto.
d. High Alert – 910 mV
1. Display: ORP alert LED on
e. Low Alert – 390 mV
1. Display: ORP alert LED on
4.4.4 Flow The integrated flow switch is pre-wired to the controller. The flow switch must be installed for safety reasons to prevent dosing chemicals when there is no flow in the circulation piping.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Return the controller to full operation by turning off the controller with the mode pushbutton. Turn the controller on again by pressing the mode pushbutton.
NOTE: Failure to complete this action will leave the controller in test mode.

NOTE:

Install the small in-line filter on the intake tubing going to the flow cell. Not installing it could potentially lead to malfunction of the flow switch.

4.4.5 Factory Defaults
To return the controller to the factory settings, place the controller in standby mode. Turn off the controller by holding down the mode pushbutton while in standby mode. Press and hold both the set level and pH Cal pushbuttons and then press the mode pushbutton. Both the pH and ORP displays will show “Ld”. The controller will be returned to the factory default settings and be placed in the test mode.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Section 5. Maintenance
5.1 Winterizing (extended shutdowns or colder climates).
1. Turn off the controller and shut off the main power to the controller.
2. Gently remove the pH and ORP sensors from the flow cell. Fill the provided protective containers (removed during installation) with pool water and re- install onto each sensor and store in a warm secure location.
3. Drain the water from the flow cell.
5.2 Cleaning the sensor tips
NOTE: It is important to keep the sensor tips clean to ensure accurate readings.
Sensor tips should be cleaned every 6 months for residential pools. Determine the necessary frequency by comparing the readings before and after the cleaning. Identical readings mean the cleaning time can be extended.
1. Turn off power to the controller. 2. Close the right and left valves at the bottom of the
the flow cell. 3. Loosen the nut on the compression fitting and
gently remove the sensor from the flow cell. 4. Rinse the sensor with clean water. 5. Gently brush the junctions, glass bulb, and metal
strip using a toothbrush for 1 minute.
NOTE: DO NOT touch the sensor tip.
6. Soak the sensors for 2 minutes in a diluted solution of muriatic acid (10 drops in 2 fl. oz of tap water).
7. Rinse the sensor in clean tap water for 1 minute. 8. Gently re-insert the sensor into the compression
fitting and hand tighten the nut. 9. Plug in the power cord for the controller. Open
the flow cell valves and wait for a few minutes for the system to stabilize, ensure there are no leaks and get an accurate reading. Adjust the Set level if necessary. 10. If the sensor does not show the expected readings, then it must be replaced.
5.3 Checking the pH Sensor
1. The pH sensor must be checked every 6 months or after any incident when the pH level goes out of range.
2. While still attached to the controller, place the sensor in a clean glass of tap water. See Figure 16.
3. Add a small amount of acid or vinegar to the water and take a reading. It should show a low number.
4. Place the sensor into a solution that is higher than 7.5 pH and verify that the reading is increasing

ENGLISH

Page 19

5. If the sensor does not show the indicated reading, then it must be replaced.

5.4 Checking the ORP Sensor
1. The ORP sensor must be checked every 6 months or after an over sanitization event.
2. Clean the sensor tip as shown in the previous section.
3. Place the sensor in a clean glass of tap water. The reading should show between 200mV and 400mV. See Figure 16.
4. After adding a pinch of Dichlor or Trichlor into the water, the reading should show between 750mV and 800mV.
NOTE: If a sanitizer with high pH is used in place of Dichlor or Trichlor, the reading should show between 650mV and 750mV.
5. If the sensor does not show the indicated readings, then it must be replaced.

pH 7.2-7.6 ORP 600-800 mV

Figure 16. Check Sensors

Page 20

ENGLISH

Section 6. Chemical Pump Tube Replacement Procedure

WARNING
Disconnect power to the TruDose before servicing by unpluging the power supply at the receptacle.
WARNING
To reduce risk of exposure, please read the following:
· Check the pump tube regularly for leakage. At the first sign of leakage, replace the pump tube.
· The use of proper personal protective equipment is mandatory when working on or near dosing pumps.
· Prior to service, shipping or storage, pump generous amounts of water or a compatible buffer solution to rinse pump.
· Consult MSDS sheet for additional information and precautions for the additive in use.
· Personnel should be skilled and trained in the proper safety and handling of the additive in use.
· Inspect tube frequently for leakage, deterioration or wear. Schedule a regular pump tube maintenance change to prevent damage to pump and/or spillage.
CAUTION
· Use extreme caution when replacing pump tube. Be careful of your fingers and DO NOT place fingers near rollers.
WARNING
To reduce risk of hazardous pressure exposure, please read the following:
· Use caution and bleed off all resident system pressure prior to attempting service or installation.
· Use caution when disconnecting discharge tubing from from pump. Discharge may be under pressure. Tubing may contain fluid being metered.

ATTENTION
· The pump must be permanently connected to a dedicated electrical circuit. No other equipment, lights, appliances, or outlets may be connected to the pump circuit.
· DO NOT apply grease, oil or lubricants to the pump tube or housing.
· Prior to pump tube replacement, inspect the entire pump head for cracks or damaged components. Ensure rollers turn freely.
· Rinse off fluid residual and clean all fluid and debris from pump head components prior to tube replacement.
· DO NOT pull excessively on pump tube. Avoid kinks or damage during tube installation.
· Inspect the suction/discharge tubing, injection point (into pipe), and injection fitting for blockages after any tube rupture. Clear or replace as required.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
6.1 Preparation
1. Follow all safety precautions prior to tube replacement and wear adequate protective equipment.
2. Prior to service, pump water or a compatible buffer solution through the pump and suction/discharge line to remove fluid and avoid contact.
3. Turn off pump. 4. Disconnect the suction and discharge connections
from pump head.
6.2 Remove Tube
NOTE: Always turn off the dosing pump before doing maintenance work.
1. Turn off the pump. 2. Remove the Phillips locking screw on the latch.
Slide the vertical tab 180 degrees from left to right to unlock the cover latch. See Figure 17.
Figure 17. Unlock the Cover Latch
3. To slide the cover off, push up on the raised edge. See Figure 18.

Figure 18. Slide Cover Off

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
4. Release the fittings from the slots to remove the tube. See Figure 19.

ENGLISH

Page 21

Figure 19. Remove Roller Assembly
5. Remove roller assembly. 6. Use non-citrus all-purpose cleaner to clean residue
from pump head housing, roller and cover. 7. Check for cracks. Replace if cracked. 8. Ensure rollers spin freely. 9. Replace roller assembly if seized, excessive side
play from wear or if rollers are visibly worn. 10. Re-install roller assembly.
6.3 Install New Tube
1. To install a new tube, insert one fitting into the slot, pull the tube around the center of the roller assembly and insert the second fitting into the other slot. See Figure 20.

Figure 21. Align the Cover
3. Plug in the TruDose controller. 4. To lock the cover in place, press down on the cover
while turning the vertical tab 180 degrees from right to left. Install the Phillips head locking screw. See Figure 22.
Figure 22. Lock the Cover
5. Reconnect the suction and discharge lines. 6. Prime the pump.

Figure 20. Install New Tube
2. Align tube housing cover with track and slide over tube until fully closed. See Figure 21.

Page 22

ENGLISH

Section 7. General Troubleshooting

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

Problem

Possible Cause

Chlorine level too low ORP set level is too low.

Corrective Action
Check chlorine level with test kit and adjust ORP set level as necessary.

Saltwater chlorinator issue.

Check the saltwater chlorinator and its cell.

Daily filtration time too low.

Increase daily filtration time.

Sensor malfunction.
pH too low (leading to high ORP value even with a low chlorine concentration)
Chlorine level too high ORP set level is too high.

Clean or replace the sensor. Adjust pH to a value between 7.2 and 7.6
Check chlorine and cyanuric acid levels with test kit and adjust set level as necessary.

pH level is too low
pH level too high
pH alert LED blinking (pH is lower than 6.9 or higher than 8.1)

Sensor tip is dirty.

Clean according to maintenance instructions.

pH too high. The chlorine concentration Measure the pH of the water. Check, clean needed to reach the ORP setpoint is high. or replace the pH sensor if needed.

pH set level is too low.

Check pH level with test kit and adjust set level as necessary.

pH dose time too high.

Reduce pH dose time (seconds).

pH sensor malfunction.

Calibrate, clean or replace the pH sensor.

Alkalinity too low.

Check and adjust alkalinity.

Incorrect Muriatic Acid dilution

Dilute muriactic acid (4:1 dilution)

pH Sensor tip is dirty.

Clean according to maintenance instructions.

Improper pH sensor calibration.

Adjust pH calibration.

pH chemical feeder is empty.

Refill the feeder.

Feed pump malfunction.

Repair the feed pump.

pH dose time too low.

Increase dose time (seconds).

Alkalinity too high.

Check and adjust alkalinity.

Problem with acid supply.

Verify the acid tank is not empty.

Controller undershooting set level.

Increase dosing time.

Manual addition.

Verify the acid was not manually added.

Controller overshooting set level.

  1. Dilute acid with water, or 2) Lower dosing time.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

Problem
ORP alert LED blinking
(ORP is lower than 390 mV or higher than 910 mV)

Possible Cause Problem with chlorine production. Problem with chlorine supply.
Controller undershooting set level.

Display and LEDs off Feeder not operating Flow LED off

No power supply. Inadequate flow.

pH alert LED ON and “Er1” displayed on the LCD screen (pH overfeeding alert ON, setpoint not reached after 60 dosing cycles)

Chemical feeder is empty Dose time too low Sensor malfunction Alkalinity too high

Feed pump malfunction

ORP alert LED ON and “Er2” displayed on the LCD screen (ORP overfeeding alert ON, setpoint not reached after set chlorination time)

Saltwater chlorinator issue Overfeed alert time too low Sensor malfunction Cyanuric acid concentration too high

Daily filtration time too low

pH too high

ENGLISH

Page 23

Corrective Action Verify chlorine was not manually added.

Verify the saltwater chlorinator powerpack and cell work properly.
Check for proper valve positions and leaks in chlorine lines.
Check circuit breaker.

Check flow through flow cell and controller.

Verify all appropriate valves are open.
Verify there is sufficient pressure in the line. Close right side valve slightly if necessary.
Verify the flow switch is securely connected to the controller terminals.
Both the pH and ORP dose outputs are disabled if the green flow LED is not illuminated.
Refill the feeder

Increase pH dose time (seconds)

Calibrate, clean or replace pH sensor

Check and adjust alkalinity

Repair the feed pump

Check the saltwater chlorinator and its cell

Increase overfeed alert time

Calibrate, clean or replace the ORP sensor

Lower cyanuric acid concentration in the pool

Increase daily filtration time

Please refer to “pH level is too high” section

Page 24

ENGLISH

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual

Section 8. Chemical Pump Tube Troubleshooting

NOTE: A leaking pump tube damages the metering pump. Inspect the pump frequently for leakage and wear. Refer to the Tube Replacement section for additional safety precautions and instructions.

Problem Tube leaking

Possible Cause Pump tube ruptured. Calcium or mineral deposits.

Excessive back pressure.

Tube life is shortened.

Tube is twisted. Tube not centered. Incompatibility with fluid. Mineral deposits at injection point.

Sediment blockage at injection fitting.
Seized rollers caused abrasion on tube. Exposure to heat or sun.

Tube connection is leaking.

Missing ferrule on suction or discharge line.
Crushed ferrule.
Ferrule in wrong orientation.

Corrective Action Replace pump tube and ferrules. Clean injection fitting, replace pump tube and ferrules. Ensure system pressure does not exceed 25 psi (1.7 bar) maximum. Replace pump tube and ferrules. Replace pump tube and ferrules. Check compatibility. Remove deposits, replace pump tube and ferrules. Maintain suction line 2-3″ above bottom of tank. Clean roller assembly or replace. Do not store tubes in high temperatures or in direct sunlight. Replace ferrule.
Replace ferrule. Reverse orientation of ferrule.

Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
NOTES

ENGLISH

Page 25

Zodiac Pool Systems LLC 2882 Whiptail Loop #100, Carlsbad, CA 92010 USA
Zodiac Pool Systems Canada, Inc. 2-3365 Mainway, Burlington, ON L7M 1A6 Canada
USA | Jandy.com | 1.800.822.7933 Canada | Jandy.ca | 1.888.647.4004
©2022 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks are the property of their respective owners. H0751300_REVF

MANUEL D’INSTALLATION ET DE FONCTIONNEMENT
pH 7.2-7.6 ORP 600-800 mV
TruDoseTM Contrôleur des produits chimiques
AVERTISSEMENT
POUR VOTRE SÉCURITÉ, ce produit doit être installé et entretenu par un entrepreneur qualifié en équipements de piscine disposant d’un permis délivré par la juridiction dans laquelle le produit est installé lorsque de telles exigences étatiques ou locales existent. Celui qui assure son entretien doit être un technicien HVAC agréé certifié en réparation et entretien de thermopompes par la juridiction dans laquelle le produit sera installé là où de telles exigences nationales ou locales existent. Le technicien doit posséder et se conformer à toutes les certifications et réglementations concernant l’achat, la manipulation, le transport et la récupération du réfrigérant R410A. En l’absence d’exigences étatiques ou locales, l’installateur ou le responsable de l’entretien doit être un professionnel disposant de suffisamment d’expérience dans l’installation et l’entretien d’équipement de piscine afin de suivre avec précision toutes les directives contenues dans ce manuel. Avant d’installer ce produit, lire et suivre tous les avertissements et toutes les directives qui accompagnent ce produit. Tout non-respect des instructions d’avertissement peut entraîner des dommages matériels, des blessures corporelles ou même la mort. Une mauvaise installation ou utilisation peut annuler la garantie.
Une mauvaise installation ou utilisation peut engendrer un danger électrique pouvant entraîner des dommages matériels ou des blessures graves, voire mortelles. À L’ATTENTION DE L’INSTALLATEUR – Le présent manuel contient des informations importantes sur l’installation, le fonctionnement et l’utilisation sécuritaire de ce produit. Ces informations doivent être transmises au propriétaire ou à l’utilisateur de cet équipement.
AVERTISSEMENT Utilisez périodiquement une trousse de test de pH et de chlore indépendant pour vérifier la fiabilité des taux de pH et de chlore. Si les capteurs de pH, de potentiel de réduction d’oxydation (ORP) ou de cellule de débit sont endommagés, sales, contaminés ou ne fonctionnent pas correctement; des résultats inexacts peuvent être signalés au système de surveillance, entraînant une chimie de l’eau inappropriée pouvant entraîner des dommages matériels,
des blessures corporelles ou la mort.

H0751300_REVF

PAGE 28

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
Table des matières

Section 1. Consignes de sécurité importantes ……………………………. 27
1.1 Consignes générales de sécurité ………………… 27
Section 2. Pour commencer …………………….. 31 2.1 Composants du système……………………………. 31 2.2 Spécifications …………………………………………… 33 2.3 Descriptions du panneau de commande………. 33 2.4 Connexion du contrôleur chimique TruDose à
un chlorateur d’eau salée Jandy en option……. 34
Section 3. Installation………………………………. 36 3.1 Configuration ……………………………………………. 36 3.2 Outils ………………………………………………………. 36 3.3 Bloc d’alimentation ……………………………………. 36 3.4 Installation du contrôleur ……………………………. 36 3.5 Installation capteurs pH et ORP ………………….. 36 3.6 Installation de la pompe de produits
chimiques ………………………………………………… 37 3.7 Mise à la terre…………………………………………… 39
Section 4. Démarrage et arrêt…………………… 40 4.1 Chimie de l’eau…………………………………………. 40 4.2 Démarrage ………………………………………………. 40 4.3 Arrêt………………………………………………………… 40 4.4 Modes et réglages…………………………………….. 40

Section 5. Entretien …………………………………. 43 5.1 Hivernage (arrêts prolongés ou climats plus
froids). …………………………………………………….. 43 5.2 Nettoyage des pointes du capteur……………….. 43 5.3 Vérification du capteur pH ………………………….. 43 5.4 Vérification du capteur ORP……………………….. 43
Section 6. Procédure de remplacement de tuyauterie de pompe à produits chimiques……………………………….. 44
6.1 Préparation………………………………………………. 44 6.2 Retirer la tuyauterie …………………………………… 44 6.3 Installer un tube neuf…………………………………. 45
Section 7. Guide de dépannage général …… 46
Section 8. Dépannage du tube de pompe à produits chimiques …………………. 48

Déclaration de conformité réglementaire FCC
Ce dispositif est conforme à la partie 15 des directives FCC. Son fonctionnement est soumis aux deux conditions suivantes :
1. Cet appareil ne doit pas provoquer d’interférences nuisibles, et
2. cet appareil doit accepter toute interférence reçue, y compris les interférences susceptibles de provoquer un fonctionnement indésirable/
MISE EN GARDE : tout changement ou modification non expressément approuvé par la partie responsable de la conformité pourrait annuler l’autorité de l’utilisateur à utiliser l’équipement.
REMARQUE : cet équipement a été testé et déclaré conforme aux limites pour un appareil numérique de Classe B, conformément à la partie 15 des directives FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l’énergie radio électrique et, s’il n’est pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux communications radio. Toutefois, il n’existe aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement cause des interférences nuisibles à la réception des signaux de radio ou de télévision, ce qui peut être déterminé en allumant et en éteignant l’équipement, l’utilisateur est encouragé à essayer de corriger les interférences en prenant une ou plusieurs des mesures suivantes :
· Réorienter ou déplacer l’antenne de réception.
· Augmenter la distance entre l’équipement et le récepteur.
· Brancher l’équipement sur une prise différente de celle sur laquelle le récepteur est connecté.
· Consulter le revendeur ou un technicien radio/TV expérimenté pour obtenir de l’aide.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

Section 1. Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES DIRECTIVES

PAGE 29

1.1 Consignes générales de sécurité
Cet appareil est destiné à être utilisé uniquement avec des applications de piscine à corps unique. Il ne doit pas être utilisé avec des applications de piscine et de spa à deux corps, ou des spas autonomes. Tout travail en lien avec l’électricité doit être effectué par un électricien qualifié, et se conformer aux codes locaux, provinciaux et nationaux. Lors de l’installation et de l’utilisation de cet équipement électrique, les consignes de sécurité élémentaires doivent toujours être respectées, notamment les mises en garde suivantes :

DANGER
SI CET ÉQUIPEMENT N’EST PAS INSTALLÉ ET UTILISÉ CORRECTEMENT, DES BLESSURES CORPORELLES GRAVES OU LA MORT PEUVENT SURVENIR. LES INSTALLATEURS, LES OPÉRATEURS DE PISCINE ET LES PROPRIÉTAIRES DE PISCINE DOIVENT LIRE TOUS LES AVERTISSEMENTS, MISES EN GARDE ET INSTRUCTIONS AVANT D’UTILISER CET ÉQUIPEMENT.
AVERTISSEMENT
AVANT D’UTILISER VOTRE PISCINE, VOTRE SPA OU VOTRE SPA, VÉRIFIER LES NIVEAUX DE pH ET DE DÉSINFECTANT DE L’EAU.
AVERTISSEMENT
RISQUE D’EFFET VENTOUSE QUI, S’IL N’EST PAS ÉVITÉ, PEUT CAUSER DES BLESSURES GRAVES, VOIRE MORTELLES. Ne pas bloquer l’aspiration de la pompe, ce qui pourrait causer des blessures graves, voire mortelles. Ne pas utiliser cette pompe pour les pataugeoires, les piscines peu profondes ou les spas disposant de drains au fond, à moins que la pompe ne soit connectée à au moins deux (2) prises d’aspiration fonctionnelles. Les ensembles d’aspiration (drains) et leurs couvercles doivent être certifiés conformes à la dernière édition publiée de la norme ANSI®/ASME® A112.19.8, ou sa norme ayant droit, ANSI/APSP-16.
AVERTISSEMENT
Travailler avec des produits chimiques pour piscine peut être dangereux, toujours porter des gants en caoutchouc et des lunettes de protection. Toujours ajouter de l’acide à l’eau, ne pas ajouter l’eau à l’acide. Toujours travailler dans un endroit bien aéré. Des éclaboussures ou des déversements d’acide peuvent causer des blessures graves et/ou des dommages matériels. Toujours suivre tous les avertissements, mises en garde et instructions de manipulation du fabricant de produits chimiques. Lors du mélange, ne pas oublier de toujours ajouter l’acide à l’eau.

AVERTISSEMENT NE PAS MÉLANGER L’HYPOCHLORITE DE SODIUM ET L’ACIDE MURIATIQUE.

AVERTISSEMENT
Au moment de mélanger l’acide et l’eau, TOUJOURS AJOUTER L’ACIDE À L’EAU. NE JAMAIS AJOUTER L’EAU À L’ACIDE. Lire et suivre attentivement toutes les instructions du fabricant de produits chimiques.
AVERTISSEMENT
Pour réduire les risques de blessures, ne pas laisser les enfants utiliser ce produit.
AVERTISSEMENT
En raison du risque potentiel d’incendie, d’électrocution ou de blessures corporelles, l’équipement Jandy doit être installé conformément au National Electrical Code® (NEC®), NFPA 70 ou au Code canadien de l’électricité (CEC) à tous les codes électriques et de sécurité locaux, ainsi que selon la loi Occupational Safety and Health Act (OSHA). Il est possible de commander des copies du NEC auprès de la National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169, États-Unis, ou de votre agence d’inspection du gouvernement. L’installation et le fonctionnement de cet équipement doivent être conformes aux codes du bâtiment et de la santé fédéraux, provinciaux et locaux.

PAGE 30

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

WARNING
DANGER ­ Risque de blessure. A) Remplacer immédiatement le cordon endommagé. B) Ne pas enfouir le cordon. C) Connecter à une prise mise à la terre seulement.
AVERTISSEMENT
Une immersion prolongée dans l’eau chaude peut entraîner une hyperthermie. L’hyperthermie survient lorsque la température interne corporelle monte de plusieurs degrés au-dessus de la température normale corporelle de 37 °C (98,6 °F). Les symptômes comprennent des étourdissements, évanouissements, somnolences, léthargies et une augmentation de la température corporelle interne. Les effets de l’hyperthermie comprennent : · Inconscience de danger imminent · Le défaut de percevoir la chaleur · Le défaut de reconnaître le besoin de quitter le spa · L’incapacité physique de quitter le spa · Lésions foetales chez la femme enceinte · Inconscience entraînant un risque de noyade
AVERTISSEMENT Pour réduire le risque de blessure · La température de l’eau dans les spas ne doit jamais dépasser 40 °C (104 °F). La température de l’eau
entre 38 °C (100 °F) et 40 °C (104 °F) est considérée comme sécuritaire pour un adulte en bonne santé. Une température d’eau inférieure est recommandée pour les enfants et lorsque l’utilisation du spa dépasse 10 minutes. · Puisque les températures de l’eau excessives ont un potentiel élevé d’endommager le foetus pendant les premiers mois de la grossesse, les femmes enceintes ou qui pensent l’être doivent limiter la température de l’eau du spa à 38 °C (100 °F). · Avant d’entrer dans un spa ou une cuve thermale, l’utilisateur devrait vérifier la température de l’eau à l’aide d’un thermomètre précis, car la tolérance des dispositifs de régulation de température de l’eau varie. · La consommation d’alcool, de drogues ou de médicaments avant ou pendant l’utilisation d’un spa ou d’une cuve thermale peut entraîner la perte de conscience et la possibilité de noyade. · Les personnes obèses ou ayant des antécédents médicaux de maladie du coeur, de diabète, de problèmes circulatoires ou de pression sanguine irrégulière devraient consulter leur médecin avant d’utiliser un spa. · Les personnes qui prennent des médicaments devraient consulter un médecin avant d’utiliser un spa ou une cuve thermale, car certains médicaments peuvent provoquer la somnolence, alors que d’autres médicaments peuvent affecter la fréquence cardiaque, la tension artérielle et la circulation.
AVERTISSEMENT · Les personnes atteintes de maladies infectieuses ne devraient pas utiliser un spa ou une cuve thermale. · Pour éviter des blessures, faire bien attention en entrant ou en sortant du spa ou de la cuve thermale. · Ne pas consommer de drogues ou d’alcool avant ou pendant l’utilisation d’un spa ou d’une cuve thermale afin
d’éviter la perte de conscience ou une possible noyade. · Les femmes enceintes ou qui pensent l’être devraient consulter un médecin avant d’utiliser un spa ou une cuve
thermale. · Une température de l’eau supérieure à 38 °C (100 °F) peut nuire à votre santé. · Avant d’entrer dans un spa ou une cuve thermale, vérifier la température de l’eau à l’aide d’un thermomètre
précis. · Ne pas utiliser un spa ou une cuve thermale immédiatement après avoir pratiqué une activité physique intense. · L’immersion prolongée dans un spa ou une cuve thermale peut être nuisible à votre santé. · Ne pas permettre l’utilisation d’appareil électrique (comme une lampe, un téléphone, un radio ou une télévision)
à moins de 1,5 m (5 pi) d’un spa ou d’une cuve thermale. · L’utilisation de l’alcool, des drogues ou des médicaments peut augmenter considérablement le risque
d’hyperthermie mortelle dans les spas ou les cuves thermales.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 31

AVERTISSEMENT
RISQUE DE DÉCHARGE ÉLECTRIQUE, D’INCENDIE, DE BLESSURES OU DE MORT. (Pour tout équipement installé de façon permanente et destiné à être utilisé sur des circuits de dérivation monophasés de 15 ou 20 a, 120 à 240 V). Raccorder uniquement à un circuit de dérivation qui est protégé par un disjoncteur de fuite à la terre (DDFT) pour le personnel. Contacter un électricien qualifié s’il n’est pas possible de vérifier que le circuit est équipé d’un différentiel ou non. Un tel DDFT doit être fourni par l’installateur et faire l’objet d’essais régulièrement. Pour tester le différentiel, appuyer sur le bouton de test. Le différentiel doit couper le DDFT de l’alimentation. Appuyer sur le bouton de remise en route. L’alimentation doit être rétablie. Si le DDFT ne fonctionne pas comme indiqué, c’est qu’il est défectueux. Si le différentiel coupe l’alimentation de la pompe sans que le bouton de test ait été enfoncé, cela indique la présence d’un courant de terre, signifiant un risque de décharge électrique. Ne pas utiliser l’appareil. Débrancher l’appareil et faire corriger le problème par un représentant de service qualifié avant toute utilisation. DÉBRANCHER TOUTES LES CONNEXIONS D’ALIMENTATION AVANT DE RÉPARER CET ÉQUIPEMENT. Toujours débrancher toujours l’alimentation au disjoncteur avant l’entretien. Le non-respect de cette consigne peut entraîner des blessures graves ou la mort.
AVERTISSEMENT
Cet appareil est destiné à être utilisé uniquement avec des applications de piscine à corps unique. Il ne doit pas être utilisé avec des applications de piscine et de spa à deux corps, ou des spas autonomes. L’utilisation de ce produit avec des applications de piscine et de spa à double corps ou des spas autonomes peut entraîner des blessures graves, des dommages matériels et annuler la garantie.
AVERTISSEMENT
Un équipement mal installé peut tomber en panne et causer des blessures graves, des dommages matériels et peut annuler la garantie. NE PAS MODIFIER CET ÉQUIPEMENT.
AVERTISSEMENT
Ne pas raccorder le système à un réseau municipal d’approvisionnement en eau non régulé ni à aucune autre source externe d’eau sous pression produisant des pressions supérieures à 2,41 BAR (35 PSI).
AVERTISSEMENT Pour réduire le risque de blessures graves ou de décès, cet équipement ne doit pas être soumis à un essai de mise sous pression de la tuyauterie. Les codes locaux peuvent exiger l’application d’un test de mise sous pression au niveau de la tuyauterie de la piscine. Généralement, ces exigences ne sont pas conçues pour être appliquées à l’équipement de piscine, comme les filtres ou les pompes. L’équipement de piscine Zodiac® est soumis à des tests de mise sous pression en usine. Toutefois, si cet AVERTISSEMENT ne peut pas être respecté et que le test de mise sous pression du système de tuyauterie doit inclure le filtre et/ou la pompe, S’ASSURER DE RESPECTER LES CONSIGNES DE SÉCURITÉ SUIVANTES : · Vérifier les serre-joints, les boulons, les couvercles, les anneaux de blocage et les accessoires du système pour s’assurer
qu’ils sont correctement installés et fixés solidement avant d’effectuer un test.
· LIBÉRER TOUT L’AIR présent dans le système avant le test.
· La pression de l’eau pendant le test NE DOIT PAS DÉPASSER 2,41 BAR (35 lb- po²).
· La température de l’eau pendant le test NE DOIT PAS DÉPASSER 38 °C (100 °F).
· Limiter la durée du test à 24 heures. Après le test, vérifier visuellement le système pour s’assurer qu’il est prêt à fonctionner.
AVIS : ces paramètres s’appliquent à l’équipement Zodiac uniquement. Pour les équipements autres queZodiac, consulter le fabricant de l’équipement.
AVERTISSEMENT
Les déversements de produits chimiques et les émanations peuvent affaiblir l’équipement de piscine/spa. La corrosion peut provoquer la panne des filtres et d’autres équipements, entraînant ainsi de graves blessures ou des dommages matériels. Ne pas ranger les produits chimiques à proximité de votre équipement.
MISE EN GARDE
Ne pas installer dans une enceinte extérieure ou sous les bords d’une cuve thermale.
MISE EN GARDE
Afin d’éviter une défaillance prématurée ou des dommages à l’équipement, le protéger de l’exposition directe à l’eau provenant des gicleurs, du ruissellement des toits et du drainage, etc. Le non-respect de cette consigne peut entraîner une défaillance de l’équipement et peut également annuler la garantie.

PAGE 32

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

AVERTISSEMENT
Les déversements de produits chimiques et les émanations peuvent affaiblir l’équipement de piscine/spa. La corrosion peut provoquer la panne des filtres et d’autres équipements, entraînant ainsi de graves blessures ou des dommages matériels. Ne pas ranger les produits chimiques à proximité de votre équipement.

DANGER
LIRE CE QUI SUIT AVANT DE MANIPULER ET DE TRAVAILLER AVEC DE L’ACIDE MURIATIQUE (AUSSI CONNUE SOUS LE NOM D’ACIDE CHLORHYDRIQUE) ET DU CHLORE (CHLORHYDRATE DE SODIUM)
L’ACIDE MURIATIQUE ET LE CHLORE (LIQUIDE ET BRUME) PEUVENT PROVOQUER DES BRÛLURES GRAVES À LA PEAU, LA BOUCHE ET LES YEUX. PEUT ÊTRE MORTEL EN CAS D’INGESTION OU D’INHALATION. L’INHALATION PEUT CAUSER DE GRAVES LÉSIONS POUMONS. IMPORTANT! RÉCIPIENT À CHLORE
LE MÉLANGE DE PRODUITS CHIMIQUES AVEC DU CHLORE OU DES RÉSIDUS DE CHLORE DANS UN RÉCIPIENT PEUT CRÉER UN GAZ MORTEL OU UNE EXPLOSION.
AVERTISSEMENT
INHALATION
L’inhalation de vapeurs peut provoquer une toux, une inflammation du nez, de la gorge et des voies respiratoires supérieures et la mort. En cas d’inhalation, se déplacer immédiatement dans une zone d’air frais.
INGESTION
La déglutition peut être fatale. Contacter immédiatement le centre antipoison local ou un médecin. Faire boire de grandes quantités d’eau ou de lait. Laisser la personne vomir. En cas de vomissement, garder la tête plus basse que les hanches pour éviter l’aspiration. Si la personne est inconsciente, tourner la tête sur le côté. Consulter immédiatement un médecin.
ENTREPOSAGE
Installer et stocke le récipient et l’acide dans un endroit sec et aéré, à l’abri de la chaleur excessive et de la lumière directe du soleil. Doit être conservé à une température inférieure à 80 °F (27 °C). S’assurer que le drainage est situé loin du bâtiment et de l’équipement.
CONTACT CUTANÉ
Laver la peau à l’eau et au savon pendant au moins 20 minutes et retirer les vêtements et chaussures contaminés. Les vêtements contaminés doivent être soigneusement nettoyés avant réutilisation.
CONTACT OCULAIRE
Rincer les yeux immédiatement avec de l’eau pendant au moins 20 minutes. Consulter immédiatement un médecin.
PROTECTION INDIVIDUELLE
VENTILATION
Utiliser le contenant à l’extérieur et dans un endroit bien ventilé.
PROTECTION OCULAIRE
Porter des lunettes de sécurité résistantes aux éclaboussures.
VÊTEMENTS
Porter des vêtements résistants aux produits chimiques lors de la manipulation ou le travail avec de l’acide et du chlore.
GANTS
Porter des gant résistants aux produits chimiques lors de la manipulation ou le travail avec de l’acide et du chlore.
ÉLIMINATION
En raison de sa nature corrosive, l’acide muriatique est un déchet dangereux lorsqu’il est renversé ou jeté. Éliminer l’acide usagé dans une installation de gestion des déchets dangereux agréée ou un installation municipale de collecte des déchets dangereux ménagers. Les petits déversements d’acide peuvent être neutralisés à l’aide de bicarbonate de soude. Verser délicatement le bicarbonate de soude sur le matériau déversé jusqu’à ce que le pétillement s’arrête, puis éponger ou ramassez les résidus. Confier le nettoyage des déversements importants aux experts : appeler le service d’incendie local ou l’équipe de déversement de matières dangereuses.

CONSERVER CES DIRECTIVES

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 33

Section 2. Pour commencer
Ce manuel procure des instructions pour l’installation et l’utilisation du contrôleur des produits chimiques TruDose
Lire les instructions d’installation et d’utilisation au complet avant de procéder à l’installation. Conservez le présent manuel dans un endroit sûr pour référence ultérieure.

2.1 Composants du système

2.1.1

Contrôleur des produits chimiques TruDose

Le contrôleur de produits chimiques TruDose permet une surveillance et un ajustement automatiques des niveaux de pH et d’ORP (le réglage nécessite un chlorateur d’eau salée en option connecté) via une interface simple et conviviale, ce qui facilite la gestion de l’équilibre de l’eau dans les piscines.

Il peut être facilement installé dans votre environnement et équipement de piscine existants et surveille et affiche les niveaux de pH et de redox à l’aide de DEL et d’affichages numériques sur le panneau avant de l’appareil. De plus, quatre
boutons de fonction séparés permettent un contrôle simple par
bouton-poussoir de ces paramètres individuels :

· Mode – Auto (en cours d’exécution), paramètres de pH, paramètres de redox.

· Niveau défini – le niveau de pH ou d’ORP doit être maintenu.

· Durée de dosage – Durée de dosage (secondes) pour le pH. Temps de suralimentation (heures) pour l’ORP.

· pH Cal – Étalonnage du pH pour la variation des capteurs de pH

Le contrôleur a une pompe péristaltique qui alimente l’acide liquide. La pompe à acide se mettra en marche si le pH mesuré est supérieur à la consigne définie par l’utilisateur.
Lorsque l’ORP mesuré par la sonde ORP est inférieur au point de consigne défini par l’utilisateur, le contrôleur active la chloration à partir du chlorateur d’eau salée en option pour produire du chlore et atteindre l’ORP souhaité. Lorsque l’ORP atteint le point de consigne, le contrôleur chimique a la capacité de désactiver la chloration du chlorateur d’eau salée. Le chlorateur d’eau salée n’est pas fourni avec le contrôleur des produits chimiques TruDose.
2.1.2 Cellule de débit avec interrupteur de débit
La cellule de débit abrite un interrupteur de débit et contient les capteurs de pH et de redox. Ces capteurs se connectent au contrôleur des produits chimiques pour surveiller les niveaux de pH et d’ORP dans l’eau.
L’interrupteur de débit vérifie que l’eau s’écoule pendant un cycle d’alimentation et envoie au contrôleur des instructions pour désactiver l’alimentation si l’eau ne s’écoule pas. Le fonctionnement de ce contrôleur sans interrupteur de débit

fonctionnel peut entraîner un sous-dosage ou un surdosage de produits chimiques.

2.1.3 Autres composants

· Capteur de pH – standard (utiliser uniquement le numéro de pièce R0894300)

· Capteur ORP Gold – standard (utiliser uniquement le numéro de pièce R0894400)

· Raccords – pour l’installation de taraudage de l’entrée/ sortie de la cellule à écoulement

· Filtre en ligne – installer avant la cellule à écoulement pour protéger le commutateur de débit et les capteurs de pH et de redox.

· Tube – 25 pieds de 3/8 po et 20 pieds de 1/4 po pour fournir de l’acide vers et depuis le réservoir d’acide.

· Pompe à pH – y compris les tubes et les raccords – pompe péristaltique intégrée pour l’acide de contrôle du pH.

· Panneau de montage – Plastique ABS avec trous de montage et quincaillerie en acier inoxydable (18 po x 10 po).

· Taraud 1/4 po NPT (inclus)

REMARQUE : L’utilisation d’acide non dilué peut entraîner des problèmes de corrosion ou de suralimentation. Utiliser uniquement de l’acide chlorhydrique (non fourni). Diluer l’acide au ratio de 4:1 en suivant les recommandations de sécurité du fabricant de produits chimiques et utiliser un équipement de protection individuelle. Par exemple : Pour un réservoir de 5 gallons, il y aurait 4 gallons d’eau et 1 gallon d’acide muriatique.

Trousse R TruDose

1

R0894300 CAPTEUR pH

2

R0894400 CAPTEUR ORP

3

R0944100 REMPLACEMENT PCBA

4

R0944300 CÂBLE D’ALIMENTATION

5

R0944400 CONTRÔLEUR SEULEMENT

6

R0944500 TUBE POLY NOIR 1/4 PO

(ROULEAU 25 PIEDS)

7

R0944600 TUBE POLY NOIR 3/8 PO

(ROULEAU 28 PIEDS)

8

R0944900 CELLULE DE DÉBIT AVEC

INTERRUPTEUR DE DÉBIT, VANN,

RACC10

9

R0945000 FILTRE EN LIGNE AVEC CRÉPINE

ET RACCORDS

10 R0945100 INTERRUPTEUR DE DÉBIT

11 R0945200 TUBES À PRESSER (2 PAQ)

12 R0945300 TROUSSE ACCESSOIRE POMPE

13 R0945400 POMPE ACIDE PÉRISTALTIQUE

14 R0961700 TROUSSE ASSEMBLAGE ROULEAU DE POMPE

15 R0962100 TRUDOSE INT CÂBLE 24 V. c.c.

PAGE 34

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

Installation typique
REMARQUE : Tous les produits chimiques doivent être injectés en aval du réchauffeur et de la cellule de débit.

*REMARQUE : Monter le transformateur d’alimentation électrique à 30 cm (1 pi) au-dessus du sol.

Prise extérieure étanche protégée par DDFT

ORP pH

pH 7,2-7,6

Cellule de débit

ORP 600-800 mV

Pompe

Filtre

*Voir Note

Réchauffeur

De la piscine

Soupape antiretour
Retour du spa

Not Cap

Do

Cellule AquaPure Retour de la piscine

Figure 1. Installation hydraulique typique d’un contrôleur des produits chimiques TruDose

1 Échantillon d’eau à la cellule de débit 2 Retour d’eau de la cellule de débit 3 Introduction d’acide
1
3 Réchauffeur
Filtre
Cellule avec capteur de débit/Temp./Salinité Retour de la piscine
Figure 2. Connexion cellule de débit – Vue de haut

AquaPure® Contrôle Centre
Ou

PureLink Centre
électrique

TruClear® XL Ou

Cellule de débit Contrôleur TruDose

Pompe

pH 7,2-7,6 ORP 600-800 mV

2
Admission piscine

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 35

2.2 Spécifications

Dimensions du système Entrée/sortie électrique Niveau réglé du pH

L 8 po x l 10 po x P 6,5 po
Entrée : 100/240 V. c.a. ~ 50/ 60 Hz 0,6 Hz Sortie : 24 V. c.c. – 1 000 mA 24 W (Alimentation électrique fournie)
7,0 à 8,0

Niveau réglé de l’ORP 400 mV à 900 mV

Minuterie de dose pH Cycle arrêté ou minuté

Alerte faible

pH 6,9, ORP 390 mV

Alerte élevée
Lecture
Alertes (bas ou haut) Alarme de suralimentation pH Alarme de suralimentation ORP

pH 8,1, ORP 910 mV
DEL fonctionnelle et affichages numériques qui alternent entre le pH et l’ORP (mV)
DEL d’alerte rouge – fixe
– Alerte DEL pH clignotante – Er1 affiché sur l’écran ACL – DEL d’alerte ORP clignotante – Er2 affiché sur l’écran ACL

2.3 Descriptions du panneau de commande
2.3.1 Affichages numériques et DEL de fonction a. pH La valeur de pH mesurée est affichée sur l’écran ACL.
· Alerte pH (bas ou haut) – DEL rouge fixe
· Alarme de suralimentation pH – DEL rouge clignotante et « Er1 » affiché sur l’écran ACD
· Dose pH – en marche – DEL verte clignotante
· Dose pH – temps d’arrêt – DEL verte fixe b. ORP La valeur ORP mesurée est affichée en millivolts (mV) et affichée sur l’écran ACL. (en alternance avec le pH).
· Alerte ORP (bas ou haut) – DEL rouge fixe
· Alarme de suralimentation ORP – DEL rouge clignotante et « Er2 » affiché sur l’écran ACL
· Dosage Redox – minuterie allumée – DEL verte clignotante
Mode – ajustements de bouton-poussoir · Auto – DEL Rouge · Réglages pH – DEL verte · Réglages ORP – DEL jaune · Mode arrêté – en attente, appuyer et tenir bouton mode 3
secondes pour arrêter le contrôleur.

Pompe péristaltique pour acide

Communication du contrôleur Affichage numérique Bouton-poussoir Voyants DEL

Capteur pH

Interrupteur

de débit

Alimentation

Contrôle de la

Capteur électrique

chloration

ORP

eau salée

Figure 3. Connexions du contrôleur

· Débit – DEL verte · Niveau de réglage – ajustements de bouton-poussoir
(monter/baisser) · Durée de dose – ajustements de bouton-poussoir (monter/
baisser) · Cal pH – ajustements de bouton-poussoir (monter/baisser) 2.3.2 Connexions électriques (périphériques) · Alimentation électrique c.a. – 100 à 240 V. c.a. , 50-60 Hz · Interrupteur de Débit – de la cellule de débit · Capteur pH (bleu) – Connexion BNC · Capteur ORP (rouge) – Connexion BNC · Contrôle chlorateur d’eau salée – 24 V. c.c.

PAGE 36

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

2.4 Connexion du contrôleur chimique TruDose à un chlorateur d’eau salée Jandy en option
AVERTISSEMENT
Débrancher l’alimentation du TruDose avant l’entretien en débranchant l’alimentation électrique au niveau de la prise.

2.4.1 Connexion du contrôleur chimique TruDose au chlorateur d’eau salée Jandy AquaPure®
Le contrôleur chimique TruDose est compatible avec le chlorateur d’eau salée Jandy AquaPure. Cela inclut les blocs d’alimentation APUREM, FUSIONM et PURELINK.

Lorsque la lecture de TruDose ORP est inférieure au point de consigne, le câble 24 V. c.c. commandera au chlorateur d’eau salée d’activer la chloration. Le chlorateur commencera à produire du chlore. L’interface utilisateur de l’électrolyseur affichera le taux de production de 0 % à 100 % de sortie de chlore.
Lorsque la lecture TruDose ORP est supérieure au point de consigne, le câble 24 V. c.c. commandera au chlorateur d’eau salée d’arrêter la chloration. L’électrolyseur ne produira pas de chlore et l’interface utilisateur de l’électrolyseur affichera « EC » (contrôle externe) clignotant.
Pour connecter le TruDose Chemical Controller à un électrolyseur d’eau salée Jandy, il faut connecter le câble 24 V. c.a. préinstallé du TruDose Chemical Controller à la carte d’interface d’alimentation (PIB) dans le bloc d’alimentation du chlorateur d’eau salée. Le cavalier ORP sur la carte PIB du bloc d’alimentation du chlorateur d’eau salée devra être déplacé vers la position 2. Se reporter à la Figure 6 pour obtenir des instructions sur la manière de déplacer le cavalier
ORP en position 2 sur le PIB du bloc d’alimentation.

Figure 5. Centre d’alimentation AquaPure® (APUREM)
MISE EN GARDE Avant d’effectuer ces tâches, couper l’alimentation au disjoncteur principal pour éviter le risque de décharge électrique pouvant entraîner des dommages matériels, des blessures graves ou la mort.

Le cavalier ORP par défaut vient de l’usine en position 1.
1. Retirer le cavalier ORP J14 de la carte.
2. Déplacer le cavalier ORP des deux broches du bas vers les deux broches du haut. Se reporter à la Figure 6.
3. Connecter le câble 24 V. c.c. du TruDose au connecteur J15 2 broches du centre d’alimentation PIB AquaPure. Se reporter à la Figure 6.
REMARQUE : Le fil noir doit être connecté à droite et le rouge à gauche.

Connecteur ORP J15 R0474300

Fils au contrôleur ORP externe
Noir
Rouge

Câble 24 V. c.c.
Figure 4. Connexion du contrôleur TruDose 24 V. c.c.

Monter cavalier
J2
J14 ORP
J2
Interface d’alimentation du générateur de chlore
Figure 6. Connexion ORP
4. La connexion RS-485 peut rester pour fournir des informations AquaPure, y compris la concentration en sel, l’état et les changements de pourcentage de production via l’application iAquaLink.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 37

2.4.2

Connexion du contrôleur chimique TruDose au chlorateur d’eau salée Jandy TruClear®

MISE EN GARDE
Avant d’effectuer ces tâches, couper l’alimentation au disjoncteur principal pour éviter le risque de décharge électrique pouvant entraîner des dommages matériels, des blessures graves ou la mort.

6. Déplacer le cavalier ORP sur la carte d’interface d’alimentation (PIB) du centre d’alimentation TruClear XL de la position 1 (par défaut) à la position 2.

1. Percer le trou inférieur gauche (situé dans la section basse tension) au bas du bloc d’alimentation TruClear XL.
2. Installer la bague fournie avec le bloc d’alimentation TruClear XL dans le trou de perforation.
Câble 24 V. c.c. à TruDose
Câble RS-485
Figure 7. Communication/connexion d’alimentation TruClear XL
3. Retirer le connecteur avec un tournevis à tête plate qui se trouve à l’extrémité du câble TruDose 24 V.c.c.
REMARQUE : La connexion RS-485 doit être supprimée pour activer le contrôle ORP via le système TruClear XL avec les informations fournies via l’application iAquaLink.
Retirer le connecteur du câble 24 V c.c. déjà installé

Câble 24 V c.c. du contrôleur TruDose

Descendre Cavalier J17 ORP

Connecteur J16 ORP

Figure 9. Centre d’alimentation PIB TruClear XL

REMARQUE : « EC » s’affichera sur l’électrolyseur d’eau salée lorsque la chloration est désactivée. Une fois l’unité allumée, le générateur de chlore ne répondra aucun changement pendant la première minute de fonctionnement. L’appareil peut sembler BLOQUÉ EN mode « EC ». Attendre quelques minutes jusqu’à ce que l’unité se soit réchauffée pour vérifier que le chlorateur a répondu à la mise en marche.

REMARQUE : Plusieurs générateurs de chlore peuvent être reliés entre eux pour être contrôlés avec un seul contrôleur ORP sans utiliser de relais et de transformateurs externes. Contacter l’usine pour plus d’informations.

Position du cavalier ORP J14 / J17
POS 1* (défaut)

  • Ne contrôlera pas correctement le chlorateur
    POS 2 (nécessaire avec TruDose)

24 V. c.c.
Unité éteinte affiche EC sur le chlorateur
Unité ON – affiche 0-100 % sur le chlorateur

0 V. c.c.
Unité ON – affiche 0-100 % sur le chlorateur
Unité éteinte affiche EC sur le chlorateur

Figure 8. Câble 24 V. c.c. TruDose
4. Insérer le câble TruDose 24VDC à travers le trou de perforation nouvellement installé et la bague au bas du bloc d’alimentation TruClear XL.
5. Installer les 2 broches du câble TruDose 24 V. c.c. sur le connecteur ORP J16 situé sur la carte d’alimentation TruClear XL. Le haut du connecteur est amovible pour faciliter l’installation.

J14 = emplacement du cavalier ORP sur la carte AquaPure. Doit monter à la position 2.
J15 = emplacement du connecteur ORP sur la carte AquaPure. Insérer le câble 24 V. c.c. ici.
J16 = emplacement du connecteur ORP sur la carte XL TruClear. Insérer le câble 24 V. c.c. ici.
J17 = emplacement du cavalier ORP sur la carte XL TruClear. Doit descendre à la position 2.

PAGE 38

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

Section 3. Installation
3.1 Configuration
1. Éteindre tous les équipements périphériques tels que les radiateurs et les pompes.
2. Relâcher la pression du système de filtration.
3.2 Outils
· Perceuse sans fil · Taraud 1/4 po NPT (fourni) · Foret 7/16 po · Foret à maçonnerie et ancrages ou autres éléments de
fixation appropriés. · Clé de 13/16 po ou pince à verrouillage de canal · Couvercle de sortie étanche pour les installations
extérieures
3.3 Bloc d’alimentation
· Le contrôleur des produits chimiques TruDose doit être connecté à une sortie extérieure étanche protégée par un disjoncteur de fuite de terre.
· Ne pas utiliser de rallonges. · L’alimentation doit être installée à au moins 1 pi
(30 cm) au-dessus de la surface du sol. S’assurer que l’alimentation électrique est protégée de l’exposition directe à l’eau des gicleurs, du ruissellement de l’eau des toits et du drainage.
ATTENTION Le contrôleur doit être alimenté uniquement avec le courant fourni et connecté à un circuit électrique dédié protégé par GFCI, classe A GFCI au Canada. Aucun autre équipement, lumière, appareil ou prise ne doit être connecté au circuit du contrôleur.
3.4 Installation du contrôleur
3.4.1 Emplacement
· Zone murale avec un accès facile · À au moins 5 pieds (1,5 m) horizontalement du bord de la
piscine et/ou du spa. Au Canada, à au moins 3 mètres (10 pieds) horizontalement du bord de la piscine et/ou du spa. · À moins de 15 pieds de la source d’alimentation DDFT
MISE EN GARDE
Afin d’éviter une défaillance prématurée ou des dommages au contrôleur protéger de l’exposition directe à l’eau provenant des gicleurs, du ruissellement des toits et du drainage, etc. Le non-respect de cette consigne peut entraîner une défaillance du contrôleur et peut également annuler la garantie.

· Le contrôleur TruDose doit être installé à au moins 2 pieds (0,6 m) à la verticale de la surface du sol. S’assurer que le contrôleur est protégé de l’exposition directe à l’eau des gicleurs, du ruissellement de l’eau des toits et du drainage.
3.4.2 Montage
REMARQUE : Le contrôleur et la cellule de débit sont montés en usine sur la carte ABS pour votre commodité.
1. Monter solidement la carte de montage ABS avec le contrôleur chimique et la cellule à débit sur le mur.
2. Percer un trou de 7/16 po et appuyez sur un orifice NPT de 1/4 po à un emplacement en aval du filtre et en amont de tout élément chauffant ou point d’introduction de produits chimiques. Installer un connecteur de tube (inclus) et un tube flexible de 3/8 po à connecter au port de la cellule à écoulement du côté gauche contenant le commutateur de débit. Le filtre en ligne sera également installé dans cette ligne dans un endroit facilement accessible.
REMARQUE : Vérifier que le filtre en ligne est installé avec des flèches directionnelles pointant dans le sens du flux (vers la cellule de débit).
3. Percer un trou de 7/16 po et tarauder un orifice NPT de 1/4 po à un endroit soumis au vide ou à une pression réduite. Installer un connecteur de tube (inclus) et un tube flexible de 3/8 po à connecter au port de la cellule à écoulement du côté droit.
REMARQUE : Nous vous recommandons d’installer ce connecteur de tube dans le trou de vidange du côté aspiration de la pompe pour de meilleures performances.
4. Couper 3 po à 6 po de longueur de tube flexible de 3/8 po et l’insérer dans le port de flux d’échantillon de la cellule de débit (centre).
3.5 Installation capteurs pH et ORP
REMARQUE : Déballer soigneusement les capteurs de pH et de redox et les mettre de côté dans un endroit dégagé jusqu’à ce qu’ils soient prêts à être installés dans la cellule de débit.
1. Vérifier que le contrôleur est hors tension. 2. Retirer soigneusement le conteneur de protection en
plastique des capteurs et le ranger dans un endroit séparé pour une réutilisation future. 3. Desserrer (ne pas retirer) l’écrou supérieur des raccords à compression en haut de la cellule de débit et faire glisser avec précaution l’extrémité en verre de chaque capteur (pH et redox) dans les raccords à compression. S’assurer que la pointe est immergée dans l’eau à moins de 1/2 po du bas de la cellule de débit. Serrer chaque écrou à la main. Ne pas utiliser des outils pour compresser les raccords. 4. Branchements électriques · Vérifier que le contrôleur est éteint.
· Connecter le connecteur du capteur de pH (bleu) au connecteur BNC gauche en bas du contrôleur.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 39

· Connecter le capteur ORP (rouge) au connecteur BNC droit en bas du contrôleur.
· Brancher l’alimentation dans la prise protégée par GFCI (les installations extérieures doivent avoir des boîtiers résistants aux intempéries installés).
REMARQUE : Continuer à surveiller l’absence de chlore par des tests manuels afin de garantir des niveaux sanitaires adéquats.

3.6 Installation de la pompe de produits chimiques
AVERTISSEMENT
RISQUE DE BRÛLURE CHIMIQUE : S’assurer que toutes les pompes sont éteintes au niveau des disjoncteurs principaux de la maison avant de percer des tuyaux. Fixer solidement toutes les conduites électriques, d’eau et de produits chimiques. Placer les pompes d’alimentation en produits chimiques et les réservoirs de stockage de produits chimiques dans un endroit sûr et sécurisé.

3.6.1

Liste de vérification des accessoires de la pompe

· Trois (3) écrous de raccordement 1/4 po · Trois (3) viroles 1/4 po · Un (1) clapet antiretour d’injection · Une (1) crépine de conduite d’aspiration pondérée 1/4 po · Un (1) rouleau de 20 pi de tube d’aspiration/évacuation
noir 1/4 po

3.6.2

Avertissements de sécurité pour pompe de produits chimiques

1. Lire tous les risques liés à la sécurité avant d’installer ou de faire l’entretien des pompes. La pompe est conçue pour l’installation et l’entretien par un personnel adéquatement formé.

2. Porter l’équipement de protection individuelle résistant aux produits chimiques requis lors d’un travail sur ou à proximité d’une pompe de dosage.

3. Installer la pompe de manière à ce qu’elle respecte tous les codes de plomberie et d’électricité nationaux et locaux.

4. Utiliser le produit approprié pour traiter les systèmes d’eau de piscine et n’utiliser que des additifs répertoriés ou approuvés pour une utilisation.

5. Inspecter fréquemment les tubes pour détecter toute fuite, détérioration ou usure. Programmer un changement d’entretien régulier de la tubulure de la pompe pour éviter d’endommager les pompes et/ou les déversements.

6. Les pompes ne sont pas recommandées pour une installation dans des zones où les fuites peuvent causer des blessures ou des dommages matériels.

Vue démontée de la soupape antiretour d’injection

Bec de canard
Sens de débit de la solution
Conduite d’évacuation
Clapet antiretour d’injection

Vue démontée d’écrou et virole
Conduite d’aspiration

Figure 10. Diagramme d’installation de la pompe de produits chimiques
NE PAS utiliser de ruban Téflon sur les filets de la pompe ou du tube

NE PAS utiliser de pinces
Serrer l’écrou à la main
Conduite d’évacuation

Vue démontée d’écrou et virole
Ferrules Remarque : Extrémités coniques de viroles de pompe. La tuyauterie doit être au fond de tous les raccordements.
Conduite d’aspiration

Figure 11. Installer la conduite d’aspiration à la tête de la pompe
3.6.3 Conduite d’aspiration à la tête de la pompe 1. Dérouler la conduite d’aspiration/évacuation. Utiliser
en dehors du réservoir à solution comme guide pour couper les bonnes longueurs de conduite d’aspiration, en s’assurant d’avoir 2 à 3 po au dessus du réservoir à solution.
REMARQUE : Laisser suffisamment de mou pour éviter les plis et les fissures de contrainte. Toujours faire une coupe carrée propre pour vous assurer que la conduite d’aspiration est exempte de bavures. L’entretien normal nécessite une taille.
REMARQUE : Les conduites d’aspiration qui s’étendent jusqu’au fond du réservoir peuvent entraîner un ramassage de débris conduisant à des injecteurs obstrués et à une défaillance possible du tube.
2. Effectuer les connexions en faisant glisser la ou les conduites dans les écrous et les viroles de connexion et serrer à la main sur les raccords de tube correspondants.
3. Serrer l’écrou à la main sur le raccord de tube fileté tout en maintenant le raccord de tube.

PAGE 40

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

REMARQUE : Un serrage excessif de la virole et de l’écrou avec une clé peut endommager les raccords, écraser les viroles et entraîner une prise d’air.
REMARQUE : NE PAS utiliser de ruban d’étanchéité pour filetage sur les raccords de tube de pompe ou d’outils pour serrer les raccords.
3.6.4 Poids d’aspiration à la ligne d’aspiration
1. Percer un trou dans le bouchon de bonde ou le couvercle du réservoir de solution. Faire glisser le tube à travers et fixer la crépine lestée à la ligne.
2. Pour fixer la crépine, pousser environ 3,5 po de conduite d’aspiration à travers le capuchon sur le corps de la crépine. Tirer sur le tube pour vous assurer qu’il est bien fixé.
3. Suspendre légèrement au-dessus du fond du réservoir pour réduire le risque d’accumulation de sédiments.
REMARQUE : NE PAS mélanger d’additifs dans le récipient de solution. Suivre les procédures de mélange recommandées selon le fabricant.

3. Enrouler l’extrémité mâle NPT (MNPT) du raccord d’injection avec 2 ou 3 tours de ruban à fileter. Si nécessaire, couper le manchon du raccord d’injection selon les besoins pour injecter le produit directement dans le flux d’eau.
4. Serrer à la main le raccord d’injection dans le raccord FNPT.
5. Installer l’écrou de raccordement et la virole sur le tuyau de refoulement de la pompe. Insérer le tube de décharge dans le raccord d’injection jusqu’à ce qu’il atteigne la base du raccord.
6. Serrer à la main l’écrou de raccordement au raccord.
7. Allumer la pompe et remettre le système sous pression. Observer le débit tel qu’il est actionné par le système et vérifier que toutes les connexions sont étanches.
8. Après une durée de dosage appropriée, effectuer un test pour les lectures souhaitées. Si nécessaire, affiner les niveaux de dosage.
REMARQUE : Le point d’injection et le raccord nécessitent un entretien périodique pour nettoyer tout dépôt ou accumulation. Pour permettre un accès rapide au point d’injection, nous recommandons l’installation de vannes d’arrêt.

25,4 cm (3,5 po) (9 cm)

Conduite d’aspiration

Crépine de conduite
d’aspiration pondérée

25,4 cm (3 po)

NE PAS utiliser de ruban Téflon sur les filets de la pompe ou du tube

Couper l’extrémité du raccordement d’injection

NE PAS utiliser de pinces

Figure 12. Installer un poids d’aspiration à la ligne d’aspiration

3.6.5

Conduite de refoulement vers la tête de pompe et le point d’injection

1. Effectuer une connexion sécurisée à la main sur le raccord de refoulement de la tête de pompe comme indiqué dans la section Instructions d’installation de la conduite d’aspiration.

REMARQUE : NE PAS utiliser de ruban d’étanchéité pour filetage sur les raccords de tube de pompe ou d’outils pour serrer les raccords.

AVERTISSEMENT
PRESSION DANGEREUSE : Couper l’eau ou la circulation et purger la pression du système.

REMARQUE : Localiser un point d’injection au-delà de toutes les pompes et filtres ou tel que déterminé par l’application.
2. Une connexion 1/4 po ou 1/2 po femelle NPT (FNPT) est requise pour l’installation du raccord d’injection. Si aucun raccord FNPT n’est disponible, en fournir un soit en taraudant le tuyau ou en installant un raccord en T de tuyau FNPT.

Point d’injection typique

Soupape d’injection

Do

Not Cap

soupape antiretour

Conduite de retour

Figure 13. Installer la conduite de refoulement vers la tête de pompe et le point d’injection

REMARQUE : L’utilisation d’acide non dilué peut entraîner des problèmes de corrosion ou de suralimentation. Utiliser uniquement de l’acide chlorhydrique (non fourni). Diluer l’acide au ratio de 4:1 en suivant les recommandations de sécurité du fabricant de produits chimiques et utiliser un équipement de protection individuelle. Par exemple : Pour un réservoir de 5 gallons, il y aurait 4 gallons d’eau et 1 gallon d’acide muriatique.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
3.7 Mise à la terre
Le National Electrical Code® (NEC® aux États-Unis) ou le Code canadien de l’électricité (CEC au Canada) exige des pièces métalliques de l’équipement électrique associé à la circulation de l’eau de la piscine et des pièces métalliques fixes à moins de 5 pieds de la paroi de la piscine aux États-Unis, 10 pi pour le Canada, à coller les uns aux autres. Vérifier les codes locaux pour déterminer si les autorités compétentes (AHJ aux États-Unis) ou les autorités compétentes au Canada font respecter le NEC ou le CEC et/ou d’autres codes d’installation locaux. Un fil de cuivre massif de 8,37 mm2 (8 AWG) est requis, conformément aux normes NEC et CEC (l’exigence CEC est de 6 AWG), la liaison devant être réalisée à l’aide d’un conducteur en cuivre massif, n° 8 AWG ou plus. Au Canada, il faut utiliser du AWG nº 6 ou plus gros. Le contrôleur des produits chimiques TruDose ne comporte aucune pièce métallique exposée nécessitant une liaison équipotentielle, ni aucune pièce métallique en contact avec le système de circulation d’eau, et ne nécessite donc pas de connexions de liaison équipotentielle.
Le National Electrical Code® (NEC®) requiert la mise à la terre de la piscine. Lorsqu’aucun(e) équipement, structure ou pièce de la piscine mis(e) à la terre n’est en connexion directe avec l’eau de la piscine, l’eau de la piscine devra être en contact direct avec une surface conductrice approuvée résistante à la corrosion qui n’expose pas moins de 5800 mm² (9 po²) de la surface de l’eau de la piscine en tout temps. La surface conductrice devra être située à un endroit où celle-ci n’est pas exposée à des dommages physiques ou à des délogements au cours des activités courantes en piscine, et devra être mise à la terre conformément aux exigences en matière de mise à la terre du NEC Article 680. Se reporter aux codes appliqués localement pour toute exigence supplémentaire en matière de mise à la terre.

FRANÇAIS

PAGE 41

PAGE 42

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

Section 4. Démarrage et arrêt
4.1 Chimie de l’eau
Commencer avec l’eau équilibrée de la piscine et du spa.
1. Utiliser une trousse de test chimique pour piscine avec des réactifs de test frais pour mesurer le pH, l’alcalinité et la dureté calcique de l’eau de la piscine. Chaque piscine est unique et un professionnel du service de piscine peut vous aider à déterminer la chimie optimale pour votre piscine.
Les valeurs ci-dessous sont les valeurs chimiques recommandées pour l’eau de piscine selon la norme ANSI/ APSP/ICC-11 pour la qualité de l’eau dans les piscines et spas publics.
Niveau sans chlore : PISCINE – Minimum 1 ppm, maximum 4 ppm. SPA – Minimum 2 ppm, maximum 5 ppm.
pH : 7,2 à 7,8
Alcalinité totale : 60 à 180 ppm
Dureté calcique : PISCINE 150 – 1 000 ppm, SPA 100 – 800 ppm.
Total des solides dissous (TSD) : Maximum 1 500 ppm (Chlore de sodium non inclus)
Indice de saturation Langelier (LSI) : -0,3 à +0,5
IMPORTANT : Les désinfectants pour piscines et/ou spas enregistrés par l’EPA doivent être utilisés conformément aux exigences d’utilisation et/ou de fonctionnement de l’étiquette du fabricant du produit acceptée par l’EPA.
4.2 Démarrage
1. Insérer le contrôleur dans la prise d’alimentation. Pour les installations à l’extérieur, s’assurer d’utiliser un couvercle de sortie étanche.
2. Allumer la pompe de filtration et vérifier le débit d’eau à travers la cellule d’écoulement en ouvrant la vanne de l’orifice d’échantillonnage (au centre) et en observant un flux d’eau constant. La vanne du côté droit peut devoir être partiellement fermée pour produire un flux constant.
REMARQUE : L’eau doit passer sur les capteurs de pH et de redox pendant au moins 10 minutes pour permettre des lectures précises et stables des niveaux de pH et de redox de la piscine.
3. Vérifier les fuites et réparer si nécessaire. 4. Ajuster et équilibrer manuellement l’eau de la piscine à
des plages acceptables à l’aide d’une trousse de test.
REMARQUE : Utiliser une trousse de test basée sur DPD pour vérifier le niveau de chlore.
5. Vérifier que la DEL de débit verte est allumée. Les sorties de dose pH et ORP sont désactivées s’il n’y a pas de débit d’eau.
6. Appuyer momentanément sur le bouton-poussoir Mode pour placer le contrôleur en mode de réglage du pH. La DEL de réglage du pH verte s’allumera. Sélectionner le niveau de pH et la durée de dosage souhaités (secondes).

7. Tout en restant en mode de réglage du pH, appuyer sur le bouton-poussoir pH Cal pour calibrer la lecture à la valeur observée lors du test manuel de l’eau.
REMARQUE : Toujours calibrer en utilisant l’eau du port d’échantillon de la cellule de débit.
8. Appuyer momentanément sur le bouton-poussoir Mode pour placer le contrôleur en mode de réglage ORP. La DEL de réglage du ORP jaune s’allumera. Sélectionner le niveau de consigne d’ORP souhaité.
REMARQUE : Si le niveau de pH dans la piscine est au niveau de consigne souhaité et que le niveau de chlore/brome est au niveau de PPM souhaité dans la piscine, le niveau de consigne de redox doit être le même que la lecture actuelle de redox en mode automatique.
4.3 Arrêt
REMARQUE Chaque fois que le bouton-poussoir Mode est momentanément enfoncé, le mode passe du réglage automatique au réglage du pH au réglage du redox, puis revient au mode automatique.
1. Appuyer momentanément sur le bouton-poussoir Mode pour placer le contrôleur en mode de réglage du pH. La DEL de réglage du pH verte s’allumera et les affichages numériques du pH et de l’ORP afficheront des tirets.
2. Appuyer et maintenir enfoncé le bouton-poussoir Mode pendant 2 secondes jusqu’à ce que les deux affichages pH et ORP indiquent OFF.
3. Le contrôleur s’éteindra et les affichages numériques et les DEL de fonction s’éteindront. La DEL de débit verte s’allumera si de l’eau s’écoule à travers la cellule de débit.
REMARQUE Le contrôleur est toujours sous tension à moins que l’alimentation ne soit débranchée.
4.4 Modes et réglages
4.4.1 Auto Il s’agit du mode de fonctionnement normal. Le contrôleur permet un fonctionnement et une surveillance complets des niveaux de pH et d’ORP (désinfectant). Aucun bouton de fonction n’est opérationnel dans ce mode.
· La DEL de fonction rouge à côté d’auto est allumée.
· L’affichage numérique alterne l’affichage entre les lectures de pH et d’ORP.
4.4.2 Réglage du pH
REMARQUE Dans ce mode, la DEL de réglage du pH verte s’allumera, les affichages numériques pH et ORP afficheront des tirets et toutes les fonctions automatiques seront désactivées. Lorsqu’un bouton-poussoir de fonction est enfoncé, l’affichage numérique indique la fonction.

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 43

a. Régler le niveau
1. Défaut : 7,4 pH 2. Plage à choisir : pH 7,0 à 8,0 (avec 0,1 incréments)
b. Minuterie de dose
1. Défaut : Dose temporisée de 30 secondes pompe pH sous tension et 5 minutes pompe d’alimentation pH en retard (temps de mélange). En mode cycle de dose minuté, la DEL de dose clignotera pendant le dosage et s’allumera de façon continue pendant la partie de retard du cycle minuté.
2. Plage à choisir : OFF et temporisé (10-900 secondes ON et 5 minutes OFF).
3. S’assurer de vérifier séparément l’alcalinité totale (TA) de votre piscine régulièrement. L’ajout d’acide à l’eau de votre piscine réduira l’alcalinité totale.
4. Pour éviter les problèmes de suralimentation, il est recommandé de démarrer l’unité avec les paramètres par défaut (30 secondes). Le temps de dosage peut être augmenté si l’appareil n’est pas en mesure de maintenir la valeur du pH à la valeur souhaitée.
c. Minuterie suralimentation
La minuterie de suralimentation désactive le dosage si le point de consigne du pH n’est pas atteint dans un certain laps de temps. Il s’agit d’une fonction de sécurité pour éviter le surdosage ou pour détecter si le réservoir d’acide est vide. Les paramètres de la minuterie sont :
1. Préréglage : 60 cycles chronométrés. La minuterie de suralimentation ne se réinitialise pas automatiquement. Elle doit être réinitialisée en éteignant puis en rallumant le contrôleur ou en faisant basculer le mode hors auto et en retournant à auto.
2. La minuterie de suralimentation est verrouillée avec la sélection de la minuterie de dose.
Lorsque la limite de cycle préréglée est atteinte, la DEL d’alerte pH clignote et « Er1» s’affiche sur l’écran ACL. La pompe doseuse pH est arrêtée pour éviter un excès d’acide dans la piscine.
d. Alerte élevée – Défaut : 8,1 pH
1. Affichage : DEL d’alerte pH activée e. Alerte basse – Défaut : 6,9 pH
· Affichage : DEL d’alerte pH activée
f. Cal pH
· Permet un réglage de +/- 0,5 pH du relevé actuel.
4.4.3 Réglage ORP
REMARQUE : Dans ce mode, la DEL de réglage ORP jaune s’allumera, les affichages numériques pH et ORP afficheront des tirets et toutes les fonctions automatiques seront désactivées. Lorsqu’un bouton-poussoir de fonction est enfoncé, l’affichage numérique indique la fonction.

Besoin de production de chlore (ORP plus bas que point de consigne)
Clignotant

Production de chlore éteinte (ORP plus élevé que point de consigne)
Désactivé(e)
Figure 14. Interfaces TruDose/APUREM
Besoin de production de chlore (ORP plus bas que point de consigne)
Clignotant

Production de chlore éteinte (ORP plus élevé que point de consigne)
Désactivé(e)

EXTERNAL CONTROL

Figure 15. Interfaces TruDose/TruClear XL
a. Régler le niveau 1. Défaut : 700 mV 2. Plage à choisir : 400 mV à 900 mV (en incréments de
10 mV). b. Stratégie de dosage
· Par défaut : le contrôleur alimente en continu le relais 24 V.c.c. contrôlant le chlorateur d’eau salée (non fourni), via le mode ORP jusqu’à ce que le point de consigne ou la temporisation de suralimentation soit atteint.

PAGE 44

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

c. Minuterie suralimentation
La minuterie de suralimentation ORP est une fonction de sécurité qui désactive le dosage si le point de consigne ORP n’est pas atteint dans un certain laps de temps.
· Éviter le surdosage de produits chimiques en cas de mesure ORP erronée / incohérente pendant une longue période.
· Détecter les problèmes de chlorateur d’eau salée.
· Défaut : La minuterie de suralimentation ORP s’allumera après 36 heures de chloration sans atteindre le point de consigne ORP.
· Le temporisateur de suralimentation ORP peut être modifié à l’aide du bouton poussoir « Dose time » en mode ORP. Défaut : 36 heures Plage à choisir : 12 heures à 96 heures de chloration (incrément de 12 heures).
Augmenter la minuterie de suralimentation si l’unité n’est pas en mesure de maintenir le point de consigne ORP défini et déclenche régulièrement l’alerte de suralimentation ORP.
· Affichage : La DEL ORP clignote en mode automatique et « Er2 » s’affiche sur l’écran ACL.
· La minuterie de suralimentation ne se réinitialise pas automatiquement. Elle doit être réinitialisée en éteignant puis en rallumant le contrôleur ou en faisant basculer le mode hors auto et en retournant à auto.
d. Alerte élevée – 910 mV
1. Affichage : DEL d’alerte ORP activée e. Alerte basse – 390 mV
1. Affichage : DEL d’alerte ORP activée
4.4.4 Débit Le contrôleur de débit intégré est pré-câblé au contrôleur. Le commutateur de débit doit être installé pour des raisons de sécurité afin d’éviter le dosage de produits chimiques lorsqu’il n’y a pas de débit dans la tuyauterie de circulation.
REMARQUE : Installer le petit filtre en ligne sur le tube d’admission allant à la cellule de débit. Ne pas l’installer pourrait potentiellement entraîner un dysfonctionnement de l’interrupteur de débit.

poussoir de mode. Les affichages pH et ORP afficheront « Ld ». Le contrôleur reviendra aux réglages d’usine par défaut et sera placé en mode test.
Remettre le contrôleur en fonctionnement complet en éteignant le contrôleur avec le bouton-poussoir de mode. Rallumer le contrôleur en appuyant sur le bouton poussoir de mode.
REMARQUE : Le défaut d’exécuter cette action laissera le contrôleur en mode test.

4.4.5 Réglages d’usine par défaut
Pour remettre le contrôleur aux réglages d’usine, placer le contrôleur en mode veille. Éteindre le contrôleur en maintenant enfoncé le bouton-poussoir de mode en mode veille. Appuyer et maintenir enfoncés les boutons-poussoirs de réglage du niveau et de pH Cal, puis appuyer sur le bouton-

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 45

Section 5. Entretien
5.1 Hivernage (arrêts prolongés ou climats plus froids).
1. Éteindre le contrôleur et couper l’alimentation principale du contrôleur.
2. Desserrer les raccords de compression et retirer les capteur pH et rH de la cellule de débit. Remplir les conteneurs de protection fournis (retirés lors de l’installation) avec de l’eau de piscine puis les réinstaller sur chaque capteur et les ranger dans un endroit chaud et sécurisé.
3. Vider l’eau de la cellule de débit.

5.3 Vérification du capteur pH
1. Le capteur de pH doit être vérifié tous les 6 mois ou après tout incident lorsque le niveau de pH sort des limites.
2. Tout en restant attaché au contrôleur, placer le capteur dans un verre d’eau du robinet propre. Se reporter à la Figure 16.
3. Ajouter une petite quantité d’acide ou de vinaigre à l’eau et faire une lecture. Il doit afficher un nombre faible.
4. Placer le capteur dans une solution dont le pH est supérieur à 7,5 et vérifier que la lecture augmente
5. Si le capteur n’affiche pas la lecture indiquée, il doit être remplacé.

5.2 Nettoyage des pointes du capteur
REMARQUE : Il est important de garder les pointes des capteurs propres pour garantir des lectures précises.
Les pointes des capteurs doivent être nettoyées tous les 6 mois pour les piscines résidentiels. Déterminer la fréquence nécessaire en comparant les lectures avant et après le nettoyage. Des lectures identiques signifient que le temps de nettoyage peut être prolongé.
1. Couper l’alimentation du contrôleur. 2. Fermer les vannes droite et gauche au bas de la cellule
de débit. 3. Desserrer l’écrou du raccord à compression et retirer
délicatement le capteur de la cellule de débit. 4. Rincer le capteur avec de l’eau propre. 5. Délicatement, brosser les joints, l’ampoule et la bande
métallique à l’aide d’une brosse à dents pendant une minute.
REMARQUE : NE PAS toucher la pointe du capteur.
6. Tremper les capteurs pendant 2 minutes dans une solution diluée d’acide chlorhydrique (10 gouttes pour 2 onces liquides d’eau du robinet).
7. Rincer le capteur dans de l’eau du robinet propre pendant une minute.
8. Réinsérer doucement le capteur dans le raccord à compression et serrer l’écrou à la main.
9. Brancher le cordon d’alimentation du contrôleur. Ouvrir les vannes de la cellule à écoulement et attendre quelques minutes que le système se stabilise, s’assurer qu’il n’y a pas de fuites et obtenir une lecture précise. Ajuster le niveau de réglage si nécessaire.
10. Si le capteur n’affiche pas les lectures attendues, il doit être remplacé.

5.4 Vérification du capteur ORP
1. Le capteur ORP doit être vérifié tous les 6 mois ou après un événement de désinfection excessive.
2. Nettoyer la pointe du capteur comme indiqué dans la section précédente.
3. Mettre les capteurs dans un verre d’eau du robinet. La lecture doit indiquer entre 200 mV et 400 mV. Se reporter à la Figure 16.
4. Après avoir ajouté une pincée de dichlore ou de trichlore dans l’eau, la lecture devrait indiquer entre 750 mV et 800 mV.
REMARQUE : Si un désinfectant avec un pH élevé est utilisé au lieu du dichlore ou trichlore, la lecture doit indiquer entre 650 mV et 750 mV.
5. Si le capteur n’affiche pas les lectures indiquées, il doit être remplacé.
pH 7.2-7.6 ORP 600-800 mV
Figure 16. Vérifier les capteurs.

PAGE 46

FRANÇAIS

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

Section 6. Procédure de remplacement de tuyauterie de pompe à produits chimiques
AVERTISSEMENT
Débrancher l’alimentation du TruDose avant l’entretien en débranchant l’alimentation électrique au niveau de la prise.
AVERTISSEMENT
Pour réduire le risque d’exposition, lire ce qui suit : · Vérifier régulièrement l’étanchéité du tube de la pompe.
Au premier signe de fuite, remplacer le tube de la pompe. · L’utilisation d’équipements de protection individuelle
appropriés est obligatoire lorsque l’on travaille sur ou à proximité des pompes de dosage. · Avant l’entretien, l’expédition ou le stockage, pomper de généreuses quantités d’eau ou une solution tampon compatible pour rincer la pompe. · Consulter la fiche MSDS pour des informations supplémentaires et des précautions pour l’additif utilisé. · Le personnel doit être qualifié et formé à la sécurité et à la manipulation appropriées de l’additif utilisé. · Inspecter fréquemment le tube pour détecter toute fuite, détérioration ou usure. Programmer un changement d’entretien régulier du tube de la pompe pour éviter d’endommager les pompes et/ou les déversements.
MISE EN GARDE
· Faire preuve de prudence extrême lors du remplacement du tube de la pompe. Faire attention aux doigts et NE PAS les mettre près des rouleaux.
AVERTISSEMENT
Pour réduire le risque d’exposition à la pression dangereuse, lire ce qui suit :
· Faire preuve de prudence et purger toute la pression du système résident avant de tenter l’entretien ou l’installation.
· Faire preuve de prudence lors du débranchement de la tuyauterie de refoulement de la pompe. La décharge peut être sous pression. La tuyauterie peut contenir du fluide à doser.
ATTENTION
· La pompe doit être connectée de manière permanente à un circuit électrique dédié. Aucun autre équipement, éclairage, appareil ou prise de courant ne peut être connecté au circuit de pompe.
· NE PAS appliquer de graisse, d’huile ou de lubrifiants sur le tube ou le boîtier de la pompe.
· Avant de remplacer le tube de pompe, inspecter l’ensemble de la tête de pompe pour détecter des fissures ou des composants endommagés. S’assurer que les rouleaux tournent librement.
· Rincer le liquide résiduel et nettoyer tout le liquide et les débris des composants de la tête de pompe avant de remplacer le tube.
· NE PAS tirer excessivement sur le tube de la pompe. Éviter les plis ou les dommages lors de l’installation du tube.
· Inspecter le tube d’aspiration/refoulement, le point d’injection (dans le tuyau) et le raccord d’injection pour détecter tout blocage après une rupture de tube. Effacer ou remplacer au besoin.

6.1 Préparation
1. Suivre toutes les consignes de sécurité avant le remplacement de tuyauterie et porter un équipement de protection individuelle adéquat.
2. Avant de faire l’entretien, pomper de l’eau ou une solution tampon compatible dans la pompe et la conduite d’aspiration et de décharge pour éliminer le fluide et éviter le contact.
3. Désactiver la pompe. 4. Déconnecter les raccordements d’aspiration et de
décharge de la tête de la pompe.
6.2 Retirer la tuyauterie
REMARQUE : Toujours éteindre la pompe de dosage avant de commencer des travaux d’entretien.
1. Arrêter la pompe. 2. Retirer les vis de blocage cruciformes sur le loquet.
Glisser la languette verticale à 180 degrés de gauche à droite pour déverrouiller le loquet du couvercle. Se reporter à la Figure 17.
Figure 17. Déverrouiller le loquet du couvercle 3. Pour enlever le couvercle glissant, pousser vers le haut
au bord levé. Se reporter à la Figure 18.
Figure 18. Enlever le couvercle glissant

Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement

FRANÇAIS

PAGE 47

4. Dégager les raccords des fentes pour enlever le tube. Se reporter à la Figure 19.

2. Aligner le couvercle du boîtier du tube avec la rainure et glisser par- dessus le

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals