H0751300 TruDose Chemical Controller
INSTALLATION AND OPERATION MANUAL
ENGLISH | FRANÇAIS | ESPAÑOL
pH 7.2-7.6 ORP 600-800 mV
TruDoseTM Chemical Controller
WARNING
FOR YOUR SAFETY – This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which
the product will be installed where such state or local requirements exist.
The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this
manual can be followed exactly. Before installing this product, read and
follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation may
void the warranty.
Improper installation and/or operation can create unwanted electrical hazard
which can cause serious injury, property damage, or death. DO NOT MODIFY THIS
EQUIPMENT. ATTENTION INSTALLER – This manual contains important information
about the installation, operation and safe use of this product. This
information should be given to the owner/ operator of this equipment.
WARNING Periodically use an independent pH and Chlorine test kit to verify
safe pH and chlorine levels. If the pH, Oxidation Reduction Potential (ORP) or
Flow Cell sensors are damaged, dirty, contaminated, or otherwise
malfunctioning; inaccurate results may be reported to the monitoring system
resulting in improper water chemistry that may result in property damager,
personal injury, or death.
H0751300_REVF
Page 2
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Table of Contents
Section 1. Important Safety Instructions ……. 3 1.1 Safety
Instructions………………………………………. 3
Section 2. Getting Started………………………….. 7 2.1 System Components ……………………………………
7 2.2 Specifications …………………………………………….. 9 2.3 Controller Panel
Descriptions……………………….. 9 2.4 Connecting the TruDose Chemical Controller
to an Optional Jandy Saltwater Chlorinator…… 10
Section 3. Installation………………………………. 12 3.1 Setup ………………………………………………………. 12
3.2 Tools ……………………………………………………….. 12 3.3 Power Supply …………………………………………… 12 3.4
Controller Installation…………………………………. 12 3.5 pH and ORP Sensors
Installation………………… 12 3.6 Chemical Pump Installation………………………… 13 3.7 Bonding
…………………………………………………… 15
Section 4. Startup and Shutdown …………….. 16 4.1 Water
Chemistry……………………………………….. 16 4.2 Startup…………………………………………………….. 16 4.3
Shutdown ………………………………………………… 16 4.4 Modes and Adjustments …………………………….. 16
Section 5. Maintenance……………………………. 19 5.1 Winterizing (extended shutdowns or
colder
climates). …………………………………………………. 19 5.2 Cleaning the sensor tips……………………………..
19 5.3 Checking the pH Sensor ……………………………. 19 5.4 Checking the ORP Sensor
…………………………. 19
Section 6. Chemical Pump Tube Replacement Procedure……………………………….. 20
6.1 Preparation………………………………………………. 20 6.2 Remove Tube …………………………………………… 20 6.3
Install New Tube……………………………………….. 21
Section 7. General Troubleshooting …………. 22
Section 8. Chemical Pump Tube Troubleshooting ……………………… 24
FCC Regulatory Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation/
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
ENGLISH
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
Page 3
1.1 Safety Instructions
This device is for use with single-body swimming pool applications only. Not
for use with dual-body pool and spa applications, or stand-alone spas. All
electrical work must be performed by a licensed electrician and conform to all
national, state, and local codes. When installing and using this electrical
equipment, basic safety precautions should always be followed, including the
following:
DANGER
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS EQUIPMENT IS NOT INSTALLED
AND OPERATED CORRECTLY. INSTALLERS, POOL OPERATERS AND POOL OWNERS MUST READ
ALL WARNINGS, CAUTIONS, AND INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
WARNING
BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF
THE WATER.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN
SERIOUS INJURY OR DEATH. Do not block pump suction, as this can cause severe
injury or death. Do not use this pump for wading pools, shallow pools, or spas
containing bottom drains, unless the pump is connected to at least two (2)
functioning suction outlets. Suction outlet (drain) assemblies and their
covers must be certified to the latest published edition of ANSI®/ASME®
A112.19.8, or its successor standard, ANSI/APSP-16.
WARNING
Working with pool chemicals can be dangerous, always wear rubber gloves and
eye protection. Always add acid to water, do not add water to acid. Always
work in a well-ventilated area. Splashing or spilling acid can cause severe
personal injury and/or property damage. Always follow all chemical
manufacturer’s warnings, cautions, and handling instructions. When mixing,
remember to always add acid to water.
WARNING DO NOT MIX SODIUM HYPOCHLORITE AND MURIATIC ACID.
WARNING
When mixing acid and water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID.
Read and follow all the chemical manufacturer’s instructions thoroughly.
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
Due to the potential risk of fire, electric shock, or injuries to persons,
Jandy equipment must be installed in accordance with the National Electrical
Code® (NEC®), NFPA 70, or the Canadian Electrical Code (CEC) in Canada, all
local electrical and safety codes, and the Occupational Safety and Health Act
(OSHA). Copies of the NEC may be ordered from the National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02169, or from your local
government inspection agency. Installation and operation of this equipment
must be in accordance with Federal, State, and local building and health
codes.
WARNING
DANGER Risk of injury. a) Replace damaged cord immediately. b) Do not bury
cord. c) Connect to a grounded, grounding type receptacle only.
Page 4
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees
above the normal body temperature of 37 °C (98.6 °F). The symptoms of
hyperthermia include dizziness, fainting, drowsiness, lethargy, and an
increase in the internal temperature of the body. The effects of hyperthermia
include: · Unawareness of impending danger · Failure to perceive heat ·
Failure to recognize the need to exit spa · Physical inability to exit spa ·
Fetal damage in pregnant women · Unconsciousness resulting in a danger of
drowning
WARNING
To Reduce the Risk of Injury · The water in a spa should never exceed 40°C
(104°F). Water temperatures between 38°C (100°F) and 40°C
(104°F) are considered safe for a healthy adult. Lower water temperatures are
recommended for young children and when spa use exceeds 10 minutes. · Since
excessive water temperatures have a high potential for causing fetal damage
during the early months of pregnancy, pregnant or possibly pregnant women
should limit spa water temperatures to 38°C (100°F). · Before entering a spa
or hot tub, the user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating devices
varies. · The use of alcohol, drugs, or medication before or during spa or hot
tub use may lead to unconsciousness with the possibility of drowning. · Obese
persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa. · Persons using medication should consult a physician
before using a spa or hot tub since some medication may induce drowsiness
while other medication may affect heart rate, blood pressure, and circulation.
WARNING · People with infectious diseases should not use a spa or hot tub. ·
To avoid injury, exercise care when entering or exiting the spa or hot tub. ·
Do not use drugs or alcohol before or during the use of a spa or hot tub to
avoid unconsciousness and
possible drowning. · Pregnant or possibly pregnant women should consult a
physician before using a spa or hot tub. · Water temperature in excess of 38°C
(100°F) may be injurious to your health. · Before entering a spa or hot tub
measure the water temperature with an accurate thermometer. · Do not use a spa
or hot tub immediately following strenuous exercise. · Prolonged immersion in
a spa or hot tub may be injurious to your health. · Do not permit any electric
appliance (such as a light, telephone, radio, or television) within 1.5 m (5
ft.) of
a spa or hot tub. · The use of alcohol, drugs or medication can greatly
increase the risk of fatal hyperthermia in hot tubs and spas.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. (For all permanently
installed equipment intended for use on 15 or 20 ampere, 120 through 240 volt,
single phase branch circuits). Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter protection for personnel
(GFCI). Contact a qualified electrician if you cannot verify that the circuit
is protected by a GFCI. A GFCI should be provided by the installer and should
be tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If
the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI
interrupts power to the pump without the test button being pushed, a ground
current is flowing, indicating the possibility of electrical shock. Do not use
the device. Disconnect the device and have the problem corrected by a
qualified service representative before using.
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THIS EQUIPMENT. Always
disconnect power at the circuit breaker before servicing. Failure to do so may
result in serious injury or death.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
ENGLISH
Page 5
WARNING
This device is for use with single-body swimming pool applications only. Not
for use with dual-body pool and spa applications, or stand-alone spas. Use of
this product with dual-body pool and spa applications or stand-alone spas may
cause severe injury, property damage, and void the warranty.
WARNING Incorrectly installed equipment may fail, causing severe injury,
property damage, and may void the warranty. DO NOT MODIFY THIS EQUIPMENT.
WARNING Do not connect the system to an unregulated city water system or other
external source of pressurized water producing pressures greater than 35 PSI.
WARNING To minimize the risk of severe injury or death, this equipment should
not be subjected to the piping system pressurization test. Local codes may
require the pool piping system to be subjected to a pressure test. These
requirements are generally not intended to apply to the pool equipment such as
filters or pumps. Zodiac® pool equipment is pressure tested at the factory.
However, if the WARNING cannot be followed and pressure testing of the piping
system must include the filter and/or pump, BE SURE TO COMPLY WITH THE
FOLLOWING SAFETY INSTRUCTIONS: · Check all clamps, bolts, lids, lock rings and
system accessories to ensure they are properly installed and
secured before testing.
· RELEASE ALL AIR in the system before testing.
· Water pressure for test must NOT EXCEED 35 PSI.
· Water temperature for test must NOT EXCEED 100°F (38°C).
· Limit test to 24 hours. After test, visually check system to be sure it is
ready for operation.
NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac
equipment, consult equipment manufacturer.
WARNING Chemical spills and fumes can weaken pool/spa equipment. Corrosion can
cause filters and other equipment to fail, resulting in severe injury or
property damage. Do not store pool chemicals near your equipment.
CAUTION Do not install within an outer enclosure or beneath the skirt of a hot
tub.
CAUTION In order to avoid premature failure or damage to the equipment,
protect the equipment from direct water exposure from sprinklers, water runoff
from rooftops and drainage, etc. Failure to comply may cause equipment
failure, and may void the warranty.
WARNING Chemical spills and fumes can weaken pool/spa equipment. Corrosion can
cause filters and other equipment to fail, resulting in severe injury or
property damage. Do not store pool chemicals near your equipment.
Page 6
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
DANGER
READ THE FOLLOWING BEFORE HANDLING AND WORKING WITH MURIATIC ACID (ALSO KNOWN
AS HYDROCHLORIC ACID) AND CHLORINE (SODIUM HYDROCHLORITE) MURIATIC ACID AND
CHLORINE (LIQUID AND MIST) CAN CAUSE SEVERE BURNS TO SKIN, MOUTH AND EYES. MAY
BE FATAL IF SWALLOWED OR INHALED. INHALATION CAN CAUSE SEVERE LUNG DAMAGE.
IMPORTANT! CHLORINE CONTAINER MIXING CHEMICALS WITH CHLORINE OR CHLORINE
RESIDUE IN CONTAINER CAN CREATE A DEADLY GAS OR AN EXPLOSION.
WARNING
INHALATION Inhalation of vapors can cause coughing, inflammation of the nose,
throat and upper respiratory tract and death. In case of inhalation, move to
an area of fresh air immediately.
INGESTION Swallowing can be fatal. Contact local poison control center or
physician immediately. Give large amounts of water or milk. Allow person to
vomit. If vomiting occurs, keep head lower than hips to avoid aspiration. If
person is unconcious, turn their head to the side. Seek immediate medical
attention.
STORAGE Install and store container and acid in a dry, ventilated place
protected from excess heat and direct sunlight. Should be stored at a
temperature below 80° F (27° C). Be sure drainage is located away from
building and equipment.
SKIN CONTACT Wash skin with soap and water for at least 20 minutes and remove
contaminated clothing and shoes. Contaminated clothes should be thoroughly
cleaned before re-use.
EYE CONTACT Flush eyes immediately with waterr for at least 20 minutes. Seek
immediate medical attention.
PERSONAL PROTECTION
VENTILATION Use container outside and in a well-ventilated area.
EYE PROTECTION Use splash-resistant safety goggles.
CLOTHING Wear chemical-resistant clothing when handling or working with acid
and chlorine.
GLOVES Wear chemical-resistant gloves when handling or working with acid and
chlorine.
DISPOSAL Because of its corrosive nature, muriatic acid is a hazardous waste
when spilled or discarded. Dispose of used acid at an approved hazardous waste
facility or at your municipal household hazardous waste collection facility.
Small spills of acid may be neutralized using baking soda. Carefully pour the
baking soda onto the spilled material until fizzing has stops, then mop or
scoop up the residue. Leave cleanup of large spills to the experts: call your
local fire department or hazardous materials spill team.
SAVE THESE INSTRUCTIONS
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Section 2. Getting Started
This manual provides installation and basic operation instructions for the
TruDose Chemical Controller.
Read the installation and operation instructions completely before proceeding
with the installation. Keep this manual in a safe place for future reference.
2.1 System Components
2.1.1 TruDose Chemical Controller The TruDose Chemical Controller allows
automatic monitoring and adjusting of pH and ORP (adjusting requires an
optional saltwater chlorinator connected) levels through a simple, user-
friendly interface, resulting in easier management of water balance in
swimming pools.
It can be easily installed into your existing pool environment and equipment
and monitors and displays the pH and ORP levels using LEDs and digital
readouts on the front panel of the unit. In addition, four separate function
buttons allow simple pushbutton control of these individual parameters:
· Mode – Auto (running), pH settings, ORP settings.
· Set level – pH or ORP level to be maintained.
· Dose Time – Dose time (seconds) for pH. Overfeed time (hours) for ORP.
· pH Cal – pH calibration for variation in pH sensors
The controller has a peristaltic pump that feeds liquid acid. The acid pump
will turn on if the pH measured is higher than the setpoint defined by the
user. When the ORP measured by the ORP sensor is lower than the setpoint
defined by the user, the controller turns on the chlorination from the
optional saltwater chlorinator to produce chlorine and reach the desired ORP.
When the ORP reaches the setpoint, the chemical controller has the ability to
turn off the chlorination from the saltwater chlorinator. The saltwater
chlorinator is not provided with the TruDose chemical controller.
2.1.2 Flow Cell with Flow Switch The flow cell houses a flow switch and holds
the pH and ORP sensors. These sensors connect to the chemical controller to
monitor the pH and ORP levels in the water. The flow switch verifies that
water is flowing during a feed cycle and sends the controller instructions to
deactivate the feed if water is not flowing. Operation of this controller
without a functioning flow switch may result in under-dosing or over-dosing of
chemicals.
ENGLISH
Page 7
2.1.3 Other Components
· pH sensor – standard (use only part number R0894300)
· ORP Gold Sensor – standard (use only part number R0894400)
· Fittings – for tapping installation of flow cell input/ output
· In-line Filter – install prior to the flow cell to protect the flow switch and the pH and ORP sensors.
· Tubing – 25 feet of 3/8″ and 20 feet of 1/4″ for providing acid to and from the acid tank.
· pH Pump – including tubing and fittings – integrated peristaltic pump for pH-controlling acid.
· Mounting Board – ABS plastic with mounting holes and stainless hardware (18″ x 10″).
· 1/4″ NPT tap (included)
NOTE:
Using undiluted acid could lead to corrosion or overfeeding issues. Use muriatic acid only (not provided). Dilute the acid 4:1 following the safety recommendations of the chemical manufacturer, and use personal protective equipment. For example: For a 5 gallon tank, there would be 4 gallons of water and 1 gallon of muriatic acid.
TruDose R-kits
1
R0894300
2
R0894400
3
R0944100
4
R0944300
5
R0944400
6
R0944500
7
R0944600
8
R0944900
9
R0945000
10 R0945100 11 R0945200 12 R0945300 13 R0945400 14 R0961700 15 R0962100
PH SENSOR ORP SENSOR PCBA REPLACEMENT POWER CABLE CONTROLLER ONLY 1/4″ BLACK POLY TUBING (25 FOOT ROLL) 3/8″ BLACK POLY TUBING (28 FOOT ROLL) FLOW CELL W/ FLOW SWITCH, VLV, FTGS10 INLINE FILTER W/SCREEN & FTGS FLOW SWITCH SQUEEZE TUBES (2 PACK) PUMP ACCESSORY KIT PERISTALTIC ACID PUMP PUMP ROLLER ASSEMBLY TRUDOSE SWC CABLE 24 VDC
Page 8
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Typical Installation
NOTE: All chemical must be injected downstream from the heater and flowcell.
GFCI-protected Watertight Outdoor
Outlet
ORP pH
pH 7.2-7.6 ORP 600-800 mV
Flow Cell
*NOTE: Mount power supply transformer 1ft (30 cm) above ground surface.
Pump
Filter
*See Note
Heater
From Pool
Check Valve
AquaPure Cell
Do
Not Cap
Pool Return
Figure 1. Typical hydraulic installation of a TruDose Chemical Controller
1 Water sample to the Flow Cell
2 Water return from the Flow Cell
3 Acid introduction
AquaPure® Control
PureLink Power Center
TruClear® XL
Center
1
OR
OR
Heater
Flow Cell TruDose Controller
3
Filter
Pump
pH 7.2-7.6 ORP 600-800 mV
2
Cell with Flow/Temp/Salinity Sensor
Pool Return
Figure 2. Flow Cell Connection – Top View
Pool Intake
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
2.2 Specifications
System Dimensions 8″ L x 10″ W x 6.5″ D
Electrical input/output
Input : 100 – 240 VAC ~ 50 / 60 Hz 0.6A
Output : 24V DC – 1000 mA 24W (Power supply provided)
pH Set Level
7.0 to 8.0
ORP set level
400 mV to 900 mV
pH dose timer
Off or timed cycle
Low Alert
pH 6.9, ORP 390mV
High Alert Readout Alerts (low or high) pH Overfeed Alarm ORP Overfeed Alarm
pH 8.1, ORP 910mV
Functional LED and numerical digital displays that alternates between pH and
ORP (mV)
Red alert LEDs – solid
– Alert pH LED blinking – Er1 displayed on the LCD screen – Alert ORP LED
blinking – Er2 displayed on the LCD screen
Peristaltic Pump for Acid
pH 7.2-7.6 ORP 600-800 mV
Controller Communication Digital Display Pushbutton LEDs
pH Sensor
Flow Switch
Power ORP Sensor
Salt Water Chlorinator
Control
Figure 3. Controller Connections
ENGLISH
Page 9
2.3 Controller Panel Descriptions
2.3.1 Digital displays and function LEDs
a. pH
The measured pH value is displayed on the LCD screen.
· pH alert (low or high) – solid red LED
· pH overfeed alarm – red LED blinking and “Er1” displayed on the LCD screen
· pH dose – running – flashing green LED
· pH dose – time off – solid green LED
b. ORP
The measured ORP value is displayed in millivolts (mV) and displayed on the
LCD screen. (alternates with pH).
· ORP Alert (low or high) – solid red LED
· ORP overfeed alarm – red LED blinking and “Er2” displayed on the LCD screen
· ORP dose – timer on – flashing green LED
Mode – pushbutton adjustments
· Auto – red LED · pH settings – green LED · ORP settings – yellow LED · OFF
mode – in standby, press and hold mode button
for 3 seconds to turn controller off.
· Flow – green LED · Set Level – pushbutton adjustments (up/down) · Dose time – pushbutton adjustments (up/down) · pH Cal – pushbutton adjustments (up/down) 2.3.2 Electrical Connections (peripherals) · AC power – 100-240 VAC, 50-60 Hz · Flow Switch – from flow cell · pH sensor (blue) – BNC connection · ORP sensor (red) – BNC connection
· Saltwater chlorinator control – 24VDC
Page 10
ENGLISH
2.4 Connecting the TruDose Chemical Controller to an Optional Jandy Saltwater Chlorinator
WARNING
Disconnect power to the TruDose before servicing by unpluging the power supply
at the receptacle.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
2.4.1
Connecting the TruDose Chemical Controller to the Jandy AquaPure® Saltwater Chlorinator
The TruDose Chemical Controller is compatible with the Jandy AquaPure Saltwater Chlorinator. This includes the
power packs APUREM, FUSIONM and PURELINK.
When the TruDose ORP reading is lower than the setpoint, the 24VDC cable will
command the saltwater chlorinator to turn on the chlorination. The chlorinator
will start to produce chlorine. The chlorinator user interface will display
the production rate of 0% to 100% chlorine output.
When the TruDose ORP reading is higher than the setpoint, the 24VDC cable will
command the saltwater chlorinator to turn off the chlorination. The
chlorinator will not produce chlorine, and the chlorinator user interface will
display “EC” (external control) flashing. To connect the TruDose Chemical
Controller to a Jandy saltwater chlorinator, you will need to connect the
preinstalled 24VDC cable from the TruDose Chemical Controller to the Power
Interface Board (PIB) in the saltwater chlorinator power pack. The ORP Jumper
on the Saltwater Chlorinator power pack PIB board will need to be moved to
Position 2. See Figure 6 for instructions how to move the ORP Jumper to
Position 2 on the power pack PIB.
pH 7.2-7.6
ORP 600-800 mV
Figure 5. AquaPure® Power Center (APUREM)
CAUTION
Disconnect power to the system at the main circuit breaker before performing
this procedure to avoid risk of electric shock which can result in property
damage, severe injury or death.
The ORP Jumper as a default comes from the factory in Position 1.
1. Remove the ORP Jumper J14 from the board. 2. Move the ORP Jumper from the
two bottom pins to
the two top pins. See Figure 6. 3. Connect the TruDose 24VDC cable to the
dedicated
2-pin connector J15 on the AquaPure power center PIB. See Figure 6.
NOTE: The black wire must be connected to the right and the red to the left.
ORP Connector
J15 R0474300
Wires to the external ORP Controller
Black
Red
24VDC Cable
Figure 4. TruDose Controller 24VDC Connection
Shift Up
J2
ORP
Jumper
J2
J14
Chlorine Generator Power Interface Board
Figure 6. ORP Connection
4. The RS-485 connection can remain to provide AquaPure information,
including salt concentration, status, and production % changes through the
iAquaLink app.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
2.4.2
Connect the TruDose Chemical Controller to the Jandy TruClear® XL Saltwater Chlorinator
CAUTION
Disconnect power to the system at the main circuit breaker before performing
this procedure to avoid risk of electric shock which can result in property
damage, severe injury or death.
1. Punch out the left bottom hole (located in the low voltage section) in the
bottom of the TruClear XL power pack.
2. Install the bushing that was provided with the
TruClear XL power pack into the punch-out hole.
ENGLISH
Page 11
6. Move down the ORP jumper on the TruClear XL power center Power Interface Board (PIB) from Position 1 (default) to Position 2.
24VDC Cable from TruDose Controller
Shift Down ORP Jumper J17
ORP Connector J16
Figure 9. TruClear XL Power Center PIB
24VDC Cable to TruDose
RS-485 Cable
Figure 7. TruClear XL Communication/Power Connection
3. Remove the connector with a flathead screwdriver that is on the end of the TruDose 24VDC cable.
NOTE:
The RS-485 connection must be removed to activate the ORP control through the TruClear XL system with info provided through the iAquaLink app.
Remove Connector from pre-installed 24VDC Cable
NOTE:
“EC” will be displayed on the saltwater chlorinator when the chlorination is OFF. Once the unit turns on, the chlorine generator will not respond to any changes during the first minute of operation. The unit may appear to be STUCK IN “EC” mode. Wait several minutes until the unit has warmed up to verify the chlorinator has responded to being turned on.
NOTE:
Multiple chlorine generators can be linked together to be controlled with one ORP controller without the use of external relays and transformers. Contact the factory for more information.
Position of ORP Jumper J14 / J17
POS 1 (default)
Will not control chlorinator properly
POS 2 (needed with TruDose)
24 VDC
Unit OFF displays EC on chlorinator Unit ON displays 0-100% on chlorinator
0 VDC
Unit ON displays 0-100% on chlorinator Unit OFF displays EC on chlorinator
Figure 8. TruDose 24VDC Cable
4. Insert the TruDose 24VDC cable through the newly installed punch-out hole
and bushing in the bottom of the TruClear XL power pack.
5. Install the 2 pins of the TruDose 24VDC cable to the ORP connector J16
located on the TruClear XL power board. The top of the connector is removable
to make installation easier.
J14 = location of the ORP jumper on the AquaPure board. Must move up to
Position 2.
J15 = location of the ORP connector on the AquaPure board. Insert the 24VDC
cable here.
J16 = location of the ORP connector on the TruClear XL board. Insert the 24VDC
cable here.
J17 = location of the ORP jumper on the TruClear XL board. Must move down to
Position 2.
Page 12
ENGLISH
Section 3. Installation
3.1 Setup
1. Turn off all peripheral equipment such as heaters and pumps.
2. Relieve pressure from the filtration system.
3.2 Tools
· Cordless drill · 1/4″ NPT Tap (provided) · 7/16″ drill bit · Masonry drill
bit and anchors or other appropriate
fasteners. · 13/16″ wrench or channel-lock pliers
· Water-tight outlet cover for outdoor installations
3.3 Power Supply
· The TruDose Chemical Controller needs to be connected to a GFCI protected
watertight outdoor outlet.
· Do not use extension cords. · The power supply must be installed at least 1
ft
(30cm) above the ground surface. Ensure the power supply is protected from
direct water exposure from sprinklers, water runoff from rooftops and
drainage.
ATTENTION
The controller must be powered only with the provided power supply, and
connected to a dedicated GFCI protected electrical circuit, Class A GFCI in
Canada. No other equipment, lights, appliances, or outlets may be connected to
the controller circuit.
3.4 Controller Installation
3.4.1 Location
· Wall area with easy access · At least 5 feet (1.5 m) horizontally from the
edge of
the pool and/or spa. In Canada, at least 3 meters (10 feet) horizontally from
the edge of the pool and/or spa.
· Within 15 feet of GFCI power source
CAUTION
In order to avoid premature failure or damage to the controller, protect the
controller from direct water exposure from sprinklers, water runoff from
rooftops and drainage, etc. Failure to comply may cause controller failure,
and may void the warranty.
· The TruDose Controller must be installed at least 2 feet (0.6 m) vertically
off the ground surface. Ensure the controller is protected from direct water
exposure from sprinklers, water runoff from rooftops and drainage.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.4.2 Mounting
NOTE: The controller and flow cell are factory mounted to the ABS board for
your convenience.
1. Securely mount ABS mounting board with the chemical controller and flow
cell on the wall.
2. Drill a 7/16″ hole and tap a 1/4″ NPT port to a location downstream from
the filter and upstream from any heater or chemical introduction point.
Install a tubing connector (included) and 3/8″ flex tubing to be connected to
the left side flow cell port containing the flow switch. The in-line filter
will also be installed in this line in an easily-accessible location.
NOTE: Verify that the in-line filter is installed with directional arrows
pointing in the direction of the flow (towards flow cell).
3. Drill a 7/16″ hole and tap a 1/4″ NPT port to a location that is subject
to vacuum or reduced pressure. Install a tubing connector (included) and 3/8″
flex tubing to be connected to the right side flow cell port.
NOTE: We recommend that this tubing connector be installed into the drain hole
on the suction side of the pump for best performance.
4. Cut 3″-6″ length of 3/8″ flex tubing and insert into the flow cell’s
sample stream port (center).
3.5 pH and ORP Sensors
Installation
NOTE: Carefully unpack the pH and ORP sensors and set aside in a clear area
until ready to install into the flow cell.
1. Verify that the controller power is off. 2. Carefully remove the plastic
protective container
from the sensors and store in a separate location for future re-use. 3. Loosen
(do not remove) the top nut of the compression fittings at the top of the flow
cell and carefully slide the glass end of each sensor (pH and ORP) into the
compression fittings. Ensure that the tip is submerged into the water to
within 1/2″ from the bottom of the flow cell. Hand tighten each nut fitting.
Do not use any tools to tighten the compression fittings. 4. Electrical
Connections · Verify that the controller is off.
· Connect the pH sensor connector (blue) to the left BNC connector on the
bottom of the controller.
· Connect the ORP sensor (red) to the right BNC connector on the bottom of the
controller.
· Plug power supply into the GFCI protected outlet (outdoor installations
should have weather proof enclosures installed).
NOTE: Continue to monitor free chlorine with manual testing to ensure proper
sanitation levels.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.6 Chemical Pump Installation
WARNING
CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit
breakers at the house before drilling into any pipes. Securely fasten all
electrical, water and chemical lines. Locate chemical feed pumps and chemical
storage tanks in a safe and secure area.
3.6.1 Pump Accessory Checklist
· Three (3) 1/4″ connecting nuts
· Three (3) 1/4″ ferrules
· One (1) injection check valves
· One (1) 1/4″ weighted suction line stainers
· One (1) 20′ roll of 1/4″ black suction/discharge tubing
3.6.2 Chemical Pump Safety Warnings 1. Read all safety hazards before
installing or
servicing the pumps. The pump is designed for installation and service by
properly trained personnel. 2. Use all required personal protective equipment
when working on or near a dosing pump. 3. Install the pump so that it can
follow all national and local plumbing and electrical codes. 4. Use the proper
product to treat swimming pool water systems and use only additives listed or
approved for use. 5. Inspect tubes frequently for leakage, deterioration or
wear. Schedule a regular pump tubing maintenance change to prevent damage to
pumps and/or spillage. 6. Pumps are not recommended for installation in areas
where leakage can cause personal injury or property damage.
Disassembled View of injection check valve
Duckbill
Flow direction of solution Discharge Line
Injection Check Valve
Disassembled view of nut and ferrule
Suction Line
ENGLISH
Page 13
DO NOT use teflon tape on pump or tube threads
DO NOT use pliers
Finger Tighten Nut
Discharge Line
Disassembled view of nut and ferrule
Ferrules Note: Beveled ends of ferrules face pump. Tubings should bottom into
all fittings.
Suction Line
Figure 11. Install Suction Line to Pump Head
3.6.3 Suction Line to Pump Head
1. Uncoil the suction/discharge line. Use outside of solution tank as a guide
to cut proper length of suction line, ensuring it will be 2-3″ above the
bottom of solution tank.
NOTE:
Allow sufficient slack to avoid kinks and stress cracks. Always make a clean square cut to assure the suction line is burr free. Normal maintenance requires trimming.
NOTE: Suction lines that extend to the bottom of the tank can result in debris
pickup leading to clogged injectors and possible tube failure.
2. Make connections by sliding the line(s) through connecting nuts and
ferrules and finger tighten to the corresponding tube fittings.
3. Finger tighten nut to the threaded tube fitting while holding the tube
fitting.
NOTE: Overtightening the ferrule and nut with a wrench may result in damaged
fittings, crushed ferrules and air pick up.
NOTE: DO NOT use thread sealant tape on pump tube connections or tools to tighten connections.
3.6.4 Suction Weight to Suction Line 1. Drill a hole into the bung cap or
solution tank lid.
Slide the tubing through and secure the weighted strainer to the line. 2. To
attach the strainer, push the approximately 3.5″ of suction line through the
cap on the strainer body. Pull tubing to make sure it is secure.
3. Suspend slightly above the tank bottom to reduce the chance of sediment
pickup.
NOTE: DO NOT mix additives in the solution container. Follow recommended
mixing procedures according to the manufacturer.
Figure 10. Chemical Pump Installation Diagram
Page 14
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
NOTE:
The injection point and fitting require periodic maintenance to clean any deposits or buildup. To allow quick access to the point of injection, we recommend the installation of shut-off valves.
Suction Line
DO NOT use teflon tape on pump or tube threads
3.5″ (9 cm)
Weighted
Suction Line
3″
Strainer
Trim injection fitting end
DO NOT use pliers
Figure 12. Install Suction Weight to Suction Line
3.6.5 Discharge Line to Pump Head and Injection Point
1. Make a secure finger tight connection on the discharge fitting of the pump
head as instructed in the Install Suction Line Instruction section.
NOTE: DO NOT use thread sealant tape on pump tube connections or tools to
tighten connections.
WARNING
HAZARDOUS PRESSURE: Shut off water or circulation and bleed system pressure.
Typical Point of Injection
Injection Valve
Do
Not Cap
Check Valve
Return Line
Figure 13. Install Discharge Line to Pump Head and Injection Point
NOTE: Locate a point of injection beyond all pumps and filters or as
determined by the application.
2. A 1/4″ or 1/2″ female NPT (FNPT) connection is required for installing the
injection fitting. If there is no FNPT fitting available, provide one by
either tapping the pipe or installing an FNPT pipe tee fitting.
3. Wrap the male NPT (MNPT) end of the injection fitting with 2 or 3 turns of
threading tape. If necessary, trim the injection fitting quill as required to
inject product directly into the flow of water.
4. Hand tighten the injection fitting into the FNPT fitting.
5. Install connecting nut and ferrule to the pump discharge tubing. Insert
discharge tubing into injection fitting until it reaches the base of the
fitting.
6. Finger tighten the connecting nut to the fitting. 7. Turn the pump on and
re-pressurize the system.
Observe the flow as actuated by the system and check all connections for
leaks.
8. After a suitable amount of dosing time, perform test for desired readings.
If necessary, fine tune the dosing levels.
NOTE:
Using undiluted acid could lead to corrosion or overfeeding issues. Use muriatic acid only (not provided). Dilute the acid 4:1 following the safety recommendations of the chemical manufacturer, and use personal protective equipment. For example: For a 5 gallon tank, there would be 4 gallons of water and 1 gallon of muriatic acid.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
3.7 Bonding
The National Electrical Code® (NEC® in the United States) or the Canadian
Electrical Code (CEC in Canada) requires metal parts of electrical equipment
associated with the pool water circulation and fixed metal parts within 5 ft
of the pool wall in the USA, 10 ft for Canada, to be bonded to each other.
Check your local codes to determine if the NEC or CEC and/or other local
installation codes are enforced by the Authority Having Jurisdiction (AHJ in
the United States) or the local competent authorities in Canada. A solid
copper 8.37mm2 (8 AWG) wire is required, per the NEC and CEC (CEC requirement
is 6 AWG), with the bonding must be accomplished by using a solid copper
conductor, No. 8 AWG or larger. In Canada, No. 6 AWG or larger must be used.
The TruDose Chemical Controller does not have any exposed metal parts
requiring equipotential bonding, nor metal parts in contact with the water
circulation system, and therefore does not require equipotential bonding
connections.
National Electrical Code® (NEC®) requires bonding of the Pool Water. Where
none of the bonded pool equipment, structures, or parts are in direct
connection with the pool water; the pool water shall be in direct contact with
an approved corrosion-resistant conductive surface that exposes not less than
5800 mm² (9 in²) of the surface area to the pool water at all times. The
conductive surface shall be located where it is not exposed to physical damage
or dislodgement during usual pool activities, and it shall be bonded in
accordance with the bonding requirements of NEC Article 680. Refer to locally
enforced codes for any additional bonding requirements.
ENGLISH
Page 15
Page 16
ENGLISH
Section 4. Startup and Shutdown
4.1 Water Chemistry
Start with Balanced Pool and Spa Water.
1. Use a pool chemistry test kit with fresh testing reagents to measure the
pH, alkalinity, and calcium hardness of the pool water. Every pool is unique,
and a pool service professional can help you determine the optimum chemistry
for your pool.
The values below are the recommend pool water chemistry values according to
ANSI/APSP/ICC-11 Standard for Water Quality in Public Pools and Spas.
Free chlorine level: POOL – Minimum 1 ppm, maximum 4 ppm. SPA – Minimum 2 ppm,
maximum 5 ppm.
pH: 7.2 – 7.8
Total Alkalinity: 60 – 180 ppm
Calcium Hardness: POOL 150 – 1,000 ppm, SPA 100 800 ppm.
Total Dissolved Solids (TDS): Maximum 1500 ppm (not including sodium chloride)
Langelier Saturation Index (LSI): -0.3 to +0.5
IMPORTANT: EPA-registered pool and/or spa sanitizers shall be used in
accordance with the product manufacturer’s EPA-accepted label for use and/or
operation requirements.
4.2 Startup
1. Plug the controller into the power outlet. For outdoor installations,
ensure the use of a watertight outlet cover.
2. Turn on the filter pump and verify the water flow through the flow cell by
opening the sample port valve (center) and observing a steady stream of water.
The right side valve may need to be partially closed to produce a steady
stream.
NOTE:
Water should pass over the pH and ORP sensors for a minimum of 10 minutes to
allow for accurate, stable readings of pH and ORP
levels from the pool.
3. Check for leaks and repair if necessary.
4. Manually adjust and balance the pool water to acceptable ranges using a test kit.
NOTE: Use a DPD based test kit to check the chlorine level.
5. Verify that the green Flow LED is illuminated. Both the pH and ORP dose
outputs are disabled if there is no water flow.
6. Press the Mode pushbutton momentarily to place the controller into pH
setting mode. The green pH setting LED will illuminate. Select the desired pH
set level and dose time (seconds).
7. While still in pH setting mode, press the pH Cal pushbutton to calibrate
the reading to the value observed through the manual testing of the water.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
NOTE: Always calibrate using water from the sample port of the flow cell.
8. Press the Mode pushbutton momentarily to place the controller in ORP
setting mode. The yellow ORP setting LED will illuminate. Select the desired
ORP set level.
NOTE:
If the pH level in the pool is at the desired set level and the chlorine/bromine level is at the desired PPM level in the pool, the ORP set level should be the same as the current ORP reading when in auto Mode.
4.3 Shutdown
NOTE
Each time the Mode pushbutton is momentarily pressed, the mode will cycle from auto to pH setting to ORP setting and then return to auto mode.
1. Press the Mode pushbutton momentarily to place the controller in pH setting mode. The green pH setting LED will illuminate and both the pH and ORP digital displays will show dashes.
2. Press and hold the Mode pushbutton for 2 seconds until both the pH and ORP
displays read OFF.
3. The controller will turn off and the digital displays and function LEDs
will go blank. The green Flow LED will be illuminated if water is flowing
through the flow cell.
NOTE There is still power to the controller unless the power supply is unplugged.
4.4 Modes and Adjustments
4.4.1 Auto
This is normal operational mode. The controller allows full operation and
monitoring of both pH and ORP (sanitizer) levels. No function pushbuttons are
operational in this mode.
· The red function LED next to auto is illuminated.
· Digital display alternates the display between the pH and ORP readings.
4.4.2 pH Setting
NOTE
While in this mode, the green pH setting LED will illuminate, both the pH and
ORP digital displays will show dashes and all auto functions will be disabled.
When a function pushbutton is pressed, the digital display will show the
function.
a. Set Level
1. Default: 7.4 pH 2. Selectable range: 7.0 – 8.0 pH (in 0.1 increments)
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
b. Dose Timer
1. Default: Timed dose of 30 seconds pH pump energized and 5 minutes pH feed
pump in delay (mixing time). In the timed dose cycle mode, the Dose LED will
flash while dosing and illuminate steadily during the delay portion of the
timed cycle.
2. Selectable range: OFF and Timed (10-900 seconds ON and 5 minutes OFF).
3. Make sure to separately check your pool’s total alkalinity (TA) regularly.
Adding acid to your pool water will lower total alkalinity.
4. To avoid overfeeding issues, it is recommended to start the unit with the
default settings (30 seconds). The dosing time can be increased if the device
is not able to maintain the pH value at the desired value.
c. Overfeed Timer
The overfeed timer turns off dosing if the pH setpoint is not reached within a
certain amount of time. This is a safety feature to avoid overdosing or to
detect if the acid tank is empty. The timer settings are:
1. Preset: 60 timed cycles. The overfeed timer does not automatically reset.
It must be reset by turning the controller off and then on or cycling the mode
out of auto and back to auto.
2. The overfeed timer is interlocked with the dose timer selection.When the
preset cycle limit is reached, the pH alert LED will flash and “Er1” will be
displayed on the LCD screen. The pH dosing pump is stopped to avoid
overfeeding acid into the pool.
When the preset cycle limit is reached, the pH alert LED will flash and “Er1”
will be displayed on the LCD screen. The pH dosing pump is stopped to avoid
overfeeding acid into the pool.
d. High Alert – Default: 8.1 pH
1. Display: pH alert LED on
e. Low Alert – Default: 6.9 pH
· Display: pH alert LED on
f. pH Cal
· Allows +/- 0.5 pH adjustment from the current reading.
4.4.3 ORP Setting
NOTE: While in this mode, the yellow ORP setting LED will illuminate, both the
pH and ORP digital displays will show dashes and all auto functions will be
disabled. When a function pushbutton is pressed, the digital display will show
the function.
ENGLISH
Need Chlorine Production (ORP lower than Setpoint)
Flashing
Page 17
100%
Chlorine Production OFF (ORP higher than Setpoint)
Off
EC
Figure 14. TruDose / APUREM Interfaces
Need Chlorine Production (ORP lower than Setpoint)
Flashing
CHLORINATING 100%
Chlorine Production OFF (ORP higher than Setpoint)
Off
EXTERNAL CONTROL
Figure 15. TruDose / TruClear XL Interfaces
a. Set Level
1. Default: 700 mV 2. Selectable range: 400 mV to 900 mV (in 10 mV
increments).
b. Dosing Strategy
· Default: the controller will continuously energize the 24VDC relay
controlling the saltwater chlorinator (not provided), via the ORP mode until
the setpoint or the overfeed timer is reached.
Page 18
ENGLISH
c. Overfeed Timer
The ORP overfeed timer is a safety function turning off the dosing if the ORP
setpoint is not reached under a certain amount of time.
· Avoid overdosing of chemicals in case of wrong / inconsistent ORP measurement for a long period of time.
· Detect saltwater chlorinator issues.
· Default: The ORP overfeed timer will turn on after 36 hours of chlorination
without reaching the ORP setpoint.
· The ORP overfeed timer can be modified using the “Dose time” pushbutton in
ORP mode. Default: 36 hours Selectable range: 12 hours to 96 hours of
chlorination (12 hours increment).
Increase the Overfeed timer if the unit is not able to maintain the defined
ORP setpoint and triggers the ORP overfeeding alert regularly.
· Display: The ORP LED is blinking in the auto mode and “Er2” is displayed on
the LCD screen.
· The overfeed timer does not automatically reset. It must be reset by turning
the controller off and then on or cycling the mode out of auto and back to
auto.
d. High Alert – 910 mV
1. Display: ORP alert LED on
e. Low Alert – 390 mV
1. Display: ORP alert LED on
4.4.4 Flow The integrated flow switch is pre-wired to the controller. The flow
switch must be installed for safety reasons to prevent dosing chemicals when
there is no flow in the circulation piping.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Return the controller to full operation by turning off the controller with the
mode pushbutton. Turn the controller on again by pressing the mode pushbutton.
NOTE: Failure to complete this action will leave the controller in test mode.
NOTE:
Install the small in-line filter on the intake tubing going to the flow cell. Not installing it could potentially lead to malfunction of the flow switch.
4.4.5 Factory Defaults
To return the controller to the factory settings, place the controller in
standby mode. Turn off the controller by holding down the mode pushbutton
while in standby mode. Press and hold both the set level and pH Cal
pushbuttons and then press the mode pushbutton. Both the pH and ORP displays
will show “Ld”. The controller will be returned to the factory default
settings and be placed in the test mode.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Section 5. Maintenance
5.1 Winterizing (extended shutdowns or colder climates).
1. Turn off the controller and shut off the main power to the controller.
2. Gently remove the pH and ORP sensors from the flow cell. Fill the provided
protective containers (removed during installation) with pool water and re-
install onto each sensor and store in a warm secure location.
3. Drain the water from the flow cell.
5.2 Cleaning the sensor tips
NOTE: It is important to keep the sensor tips clean to ensure accurate
readings.
Sensor tips should be cleaned every 6 months for residential pools. Determine
the necessary frequency by comparing the readings before and after the
cleaning. Identical readings mean the cleaning time can be extended.
1. Turn off power to the controller. 2. Close the right and left valves at
the bottom of the
the flow cell. 3. Loosen the nut on the compression fitting and
gently remove the sensor from the flow cell. 4. Rinse the sensor with clean
water. 5. Gently brush the junctions, glass bulb, and metal
strip using a toothbrush for 1 minute.
NOTE: DO NOT touch the sensor tip.
6. Soak the sensors for 2 minutes in a diluted solution of muriatic acid (10
drops in 2 fl. oz of tap water).
7. Rinse the sensor in clean tap water for 1 minute. 8. Gently re-insert the
sensor into the compression
fitting and hand tighten the nut. 9. Plug in the power cord for the
controller. Open
the flow cell valves and wait for a few minutes for the system to stabilize,
ensure there are no leaks and get an accurate reading. Adjust the Set level if
necessary. 10. If the sensor does not show the expected readings, then it must
be replaced.
5.3 Checking the pH Sensor
1. The pH sensor must be checked every 6 months or after any incident when
the pH level goes out of range.
2. While still attached to the controller, place the sensor in a clean glass
of tap water. See Figure 16.
3. Add a small amount of acid or vinegar to the water and take a reading. It
should show a low number.
4. Place the sensor into a solution that is higher than 7.5 pH and verify
that the reading is increasing
ENGLISH
Page 19
5. If the sensor does not show the indicated reading, then it must be replaced.
5.4 Checking the ORP Sensor
1. The ORP sensor must be checked every 6 months or after an over
sanitization event.
2. Clean the sensor tip as shown in the previous section.
3. Place the sensor in a clean glass of tap water. The reading should show
between 200mV and 400mV. See Figure 16.
4. After adding a pinch of Dichlor or Trichlor into the water, the reading
should show between 750mV and 800mV.
NOTE: If a sanitizer with high pH is used in place of Dichlor or Trichlor, the
reading should show between 650mV and 750mV.
5. If the sensor does not show the indicated readings, then it must be
replaced.
pH 7.2-7.6 ORP 600-800 mV
Figure 16. Check Sensors
Page 20
ENGLISH
Section 6. Chemical Pump Tube Replacement Procedure
WARNING
Disconnect power to the TruDose before servicing by unpluging the power supply
at the receptacle.
WARNING
To reduce risk of exposure, please read the following:
· Check the pump tube regularly for leakage. At the first sign of leakage,
replace the pump tube.
· The use of proper personal protective equipment is mandatory when working on
or near dosing pumps.
· Prior to service, shipping or storage, pump generous amounts of water or a
compatible buffer solution to rinse pump.
· Consult MSDS sheet for additional information and precautions for the
additive in use.
· Personnel should be skilled and trained in the proper safety and handling of
the additive in use.
· Inspect tube frequently for leakage, deterioration or wear. Schedule a
regular pump tube maintenance change to prevent damage to pump and/or
spillage.
CAUTION
· Use extreme caution when replacing pump tube. Be careful of your fingers and
DO NOT place fingers near rollers.
WARNING
To reduce risk of hazardous pressure exposure, please read the following:
· Use caution and bleed off all resident system pressure prior to attempting
service or installation.
· Use caution when disconnecting discharge tubing from from pump. Discharge
may be under pressure. Tubing may contain fluid being metered.
ATTENTION
· The pump must be permanently connected to a dedicated electrical circuit. No
other equipment, lights, appliances, or outlets may be connected to the pump
circuit.
· DO NOT apply grease, oil or lubricants to the pump tube or housing.
· Prior to pump tube replacement, inspect the entire pump head for cracks or
damaged components. Ensure rollers turn freely.
· Rinse off fluid residual and clean all fluid and debris from pump head
components prior to tube replacement.
· DO NOT pull excessively on pump tube. Avoid kinks or damage during tube
installation.
· Inspect the suction/discharge tubing, injection point (into pipe), and
injection fitting for blockages after any tube rupture. Clear or replace as
required.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
6.1 Preparation
1. Follow all safety precautions prior to tube replacement and wear adequate
protective equipment.
2. Prior to service, pump water or a compatible buffer solution through the
pump and suction/discharge line to remove fluid and avoid contact.
3. Turn off pump. 4. Disconnect the suction and discharge connections
from pump head.
6.2 Remove Tube
NOTE: Always turn off the dosing pump before doing maintenance work.
1. Turn off the pump. 2. Remove the Phillips locking screw on the latch.
Slide the vertical tab 180 degrees from left to right to unlock the cover
latch. See Figure 17.
Figure 17. Unlock the Cover Latch
3. To slide the cover off, push up on the raised edge. See Figure 18.
Figure 18. Slide Cover Off
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
4. Release the fittings from the slots to remove the tube. See Figure 19.
ENGLISH
Page 21
Figure 19. Remove Roller Assembly
5. Remove roller assembly. 6. Use non-citrus all-purpose cleaner to clean
residue
from pump head housing, roller and cover. 7. Check for cracks. Replace if
cracked. 8. Ensure rollers spin freely. 9. Replace roller assembly if seized,
excessive side
play from wear or if rollers are visibly worn. 10. Re-install roller assembly.
6.3 Install New Tube
1. To install a new tube, insert one fitting into the slot, pull the tube
around the center of the roller assembly and insert the second fitting into
the other slot. See Figure 20.
Figure 21. Align the Cover
3. Plug in the TruDose controller. 4. To lock the cover in place, press down
on the cover
while turning the vertical tab 180 degrees from right to left. Install the
Phillips head locking screw. See Figure 22.
Figure 22. Lock the Cover
5. Reconnect the suction and discharge lines. 6. Prime the pump.
Figure 20. Install New Tube
2. Align tube housing cover with track and slide over tube until fully
closed. See Figure 21.
Page 22
ENGLISH
Section 7. General Troubleshooting
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Problem
Possible Cause
Chlorine level too low ORP set level is too low.
Corrective Action
Check chlorine level with test kit and adjust ORP set level as necessary.
Saltwater chlorinator issue.
Check the saltwater chlorinator and its cell.
Daily filtration time too low.
Increase daily filtration time.
Sensor malfunction.
pH too low (leading to high ORP value even with a low chlorine concentration)
Chlorine level too high ORP set level is too high.
Clean or replace the sensor. Adjust pH to a value between 7.2 and 7.6
Check chlorine and cyanuric acid levels with test kit and adjust set level as
necessary.
pH level is too low
pH level too high
pH alert LED blinking (pH is lower than 6.9 or higher than 8.1)
Sensor tip is dirty.
Clean according to maintenance instructions.
pH too high. The chlorine concentration Measure the pH of the water. Check, clean needed to reach the ORP setpoint is high. or replace the pH sensor if needed.
pH set level is too low.
Check pH level with test kit and adjust set level as necessary.
pH dose time too high.
Reduce pH dose time (seconds).
pH sensor malfunction.
Calibrate, clean or replace the pH sensor.
Alkalinity too low.
Check and adjust alkalinity.
Incorrect Muriatic Acid dilution
Dilute muriactic acid (4:1 dilution)
pH Sensor tip is dirty.
Clean according to maintenance instructions.
Improper pH sensor calibration.
Adjust pH calibration.
pH chemical feeder is empty.
Refill the feeder.
Feed pump malfunction.
Repair the feed pump.
pH dose time too low.
Increase dose time (seconds).
Alkalinity too high.
Check and adjust alkalinity.
Problem with acid supply.
Verify the acid tank is not empty.
Controller undershooting set level.
Increase dosing time.
Manual addition.
Verify the acid was not manually added.
Controller overshooting set level.
- Dilute acid with water, or 2) Lower dosing time.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Problem
ORP alert LED blinking
(ORP is lower than 390 mV or higher than 910 mV)
Possible Cause Problem with chlorine production. Problem with chlorine supply.
Controller undershooting set level.
Display and LEDs off Feeder not operating Flow LED off
No power supply. Inadequate flow.
pH alert LED ON and “Er1” displayed on the LCD screen (pH overfeeding alert ON, setpoint not reached after 60 dosing cycles)
Chemical feeder is empty Dose time too low Sensor malfunction Alkalinity too high
Feed pump malfunction
ORP alert LED ON and “Er2” displayed on the LCD screen (ORP overfeeding alert ON, setpoint not reached after set chlorination time)
Saltwater chlorinator issue Overfeed alert time too low Sensor malfunction Cyanuric acid concentration too high
Daily filtration time too low
pH too high
ENGLISH
Page 23
Corrective Action Verify chlorine was not manually added.
Verify the saltwater chlorinator powerpack and cell work properly.
Check for proper valve positions and leaks in chlorine lines.
Check circuit breaker.
Check flow through flow cell and controller.
Verify all appropriate valves are open.
Verify there is sufficient pressure in the line. Close right side valve
slightly if necessary.
Verify the flow switch is securely connected to the controller terminals.
Both the pH and ORP dose outputs are disabled if the green flow LED is not
illuminated.
Refill the feeder
Increase pH dose time (seconds)
Calibrate, clean or replace pH sensor
Check and adjust alkalinity
Repair the feed pump
Check the saltwater chlorinator and its cell
Increase overfeed alert time
Calibrate, clean or replace the ORP sensor
Lower cyanuric acid concentration in the pool
Increase daily filtration time
Please refer to “pH level is too high” section
Page 24
ENGLISH
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
Section 8. Chemical Pump Tube Troubleshooting
NOTE: A leaking pump tube damages the metering pump. Inspect the pump frequently for leakage and wear. Refer to the Tube Replacement section for additional safety precautions and instructions.
Problem Tube leaking
Possible Cause Pump tube ruptured. Calcium or mineral deposits.
Excessive back pressure.
Tube life is shortened.
Tube is twisted. Tube not centered. Incompatibility with fluid. Mineral deposits at injection point.
Sediment blockage at injection fitting.
Seized rollers caused abrasion on tube. Exposure to heat or sun.
Tube connection is leaking.
Missing ferrule on suction or discharge line.
Crushed ferrule.
Ferrule in wrong orientation.
Corrective Action Replace pump tube and ferrules. Clean injection fitting,
replace pump tube and ferrules. Ensure system pressure does not exceed 25 psi
(1.7 bar) maximum. Replace pump tube and ferrules. Replace pump tube and
ferrules. Check compatibility. Remove deposits, replace pump tube and
ferrules. Maintain suction line 2-3″ above bottom of tank. Clean roller
assembly or replace. Do not store tubes in high temperatures or in direct
sunlight. Replace ferrule.
Replace ferrule. Reverse orientation of ferrule.
Jandy® TruDoseTM Chemical Controller | Installation & Operation Manual
NOTES
ENGLISH
Page 25
Zodiac Pool Systems LLC 2882 Whiptail Loop #100, Carlsbad, CA 92010 USA
Zodiac Pool Systems Canada, Inc. 2-3365 Mainway, Burlington, ON L7M 1A6 Canada
USA | Jandy.com | 1.800.822.7933 Canada | Jandy.ca | 1.888.647.4004
©2022 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered
trademark of Zodiac International, S.A.S.U., used under license. All other
trademarks are the property of their respective owners. H0751300_REVF
MANUEL D’INSTALLATION ET DE FONCTIONNEMENT
pH 7.2-7.6 ORP 600-800 mV
TruDoseTM Contrôleur des produits chimiques
AVERTISSEMENT
POUR VOTRE SÉCURITÉ, ce produit doit être installé et entretenu par un
entrepreneur qualifié en équipements de piscine disposant d’un permis délivré
par la juridiction dans laquelle le produit est installé lorsque de telles
exigences étatiques ou locales existent. Celui qui assure son entretien doit
être un technicien HVAC agréé certifié en réparation et entretien de
thermopompes par la juridiction dans laquelle le produit sera installé là où
de telles exigences nationales ou locales existent. Le technicien doit
posséder et se conformer à toutes les certifications et réglementations
concernant l’achat, la manipulation, le transport et la récupération du
réfrigérant R410A. En l’absence d’exigences étatiques ou locales,
l’installateur ou le responsable de l’entretien doit être un professionnel
disposant de suffisamment d’expérience dans l’installation et l’entretien
d’équipement de piscine afin de suivre avec précision toutes les directives
contenues dans ce manuel. Avant d’installer ce produit, lire et suivre tous
les avertissements et toutes les directives qui accompagnent ce produit. Tout
non-respect des instructions d’avertissement peut entraîner des dommages
matériels, des blessures corporelles ou même la mort. Une mauvaise
installation ou utilisation peut annuler la garantie.
Une mauvaise installation ou utilisation peut engendrer un danger électrique
pouvant entraîner des dommages matériels ou des blessures graves, voire
mortelles. À L’ATTENTION DE L’INSTALLATEUR – Le présent manuel contient des
informations importantes sur l’installation, le fonctionnement et
l’utilisation sécuritaire de ce produit. Ces informations doivent être
transmises au propriétaire ou à l’utilisateur de cet équipement.
AVERTISSEMENT Utilisez périodiquement une trousse de test de pH et de chlore
indépendant pour vérifier la fiabilité des taux de pH et de chlore. Si les
capteurs de pH, de potentiel de réduction d’oxydation (ORP) ou de cellule de
débit sont endommagés, sales, contaminés ou ne fonctionnent pas correctement;
des résultats inexacts peuvent être signalés au système de surveillance,
entraînant une chimie de l’eau inappropriée pouvant entraîner des dommages
matériels,
des blessures corporelles ou la mort.
H0751300_REVF
PAGE 28
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et
de fonctionnement
Table des matières
Section 1. Consignes de sécurité importantes ……………………………. 27
1.1 Consignes générales de sécurité ………………… 27
Section 2. Pour commencer …………………….. 31 2.1 Composants du système…………………………….
31 2.2 Spécifications …………………………………………… 33 2.3 Descriptions du panneau de
commande………. 33 2.4 Connexion du contrôleur chimique TruDose à
un chlorateur d’eau salée Jandy en option……. 34
Section 3. Installation………………………………. 36 3.1 Configuration …………………………………………….
36 3.2 Outils ………………………………………………………. 36 3.3 Bloc d’alimentation
……………………………………. 36 3.4 Installation du contrôleur ……………………………. 36 3.5
Installation capteurs pH et ORP ………………….. 36 3.6 Installation de la pompe de
produits
chimiques ………………………………………………… 37 3.7 Mise à la terre…………………………………………… 39
Section 4. Démarrage et arrêt…………………… 40 4.1 Chimie de l’eau………………………………………….
40 4.2 Démarrage ………………………………………………. 40 4.3 Arrêt………………………………………………………… 40 4.4
Modes et réglages…………………………………….. 40
Section 5. Entretien …………………………………. 43 5.1 Hivernage (arrêts prolongés ou
climats plus
froids). …………………………………………………….. 43 5.2 Nettoyage des pointes du
capteur……………….. 43 5.3 Vérification du capteur pH ………………………….. 43 5.4
Vérification du capteur ORP……………………….. 43
Section 6. Procédure de remplacement de tuyauterie de pompe à produits
chimiques……………………………….. 44
6.1 Préparation………………………………………………. 44 6.2 Retirer la tuyauterie ……………………………………
44 6.3 Installer un tube neuf…………………………………. 45
Section 7. Guide de dépannage général …… 46
Section 8. Dépannage du tube de pompe à produits chimiques …………………. 48
Déclaration de conformité réglementaire FCC
Ce dispositif est conforme à la partie 15 des directives FCC. Son
fonctionnement est soumis aux deux conditions suivantes :
1. Cet appareil ne doit pas provoquer d’interférences nuisibles, et
2. cet appareil doit accepter toute interférence reçue, y compris les
interférences susceptibles de provoquer un fonctionnement indésirable/
MISE EN GARDE : tout changement ou modification non expressément approuvé par
la partie responsable de la conformité pourrait annuler l’autorité de
l’utilisateur à utiliser l’équipement.
REMARQUE : cet équipement a été testé et déclaré conforme aux limites pour un
appareil numérique de Classe B, conformément à la partie 15 des directives
FCC. Ces limites sont conçues pour fournir une protection raisonnable contre
les interférences nuisibles dans une installation résidentielle. Cet
équipement génère, utilise et peut émettre de l’énergie radio électrique et,
s’il n’est pas installé et utilisé conformément aux instructions, peut causer
des interférences nuisibles aux communications radio. Toutefois, il n’existe
aucune garantie que des interférences ne se produiront pas dans une
installation particulière. Si cet équipement cause des interférences nuisibles
à la réception des signaux de radio ou de télévision, ce qui peut être
déterminé en allumant et en éteignant l’équipement, l’utilisateur est
encouragé à essayer de corriger les interférences en prenant une ou plusieurs
des mesures suivantes :
· Réorienter ou déplacer l’antenne de réception.
· Augmenter la distance entre l’équipement et le récepteur.
· Brancher l’équipement sur une prise différente de celle sur laquelle le
récepteur est connecté.
· Consulter le revendeur ou un technicien radio/TV expérimenté pour obtenir de
l’aide.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
Section 1. Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES DIRECTIVES
PAGE 29
1.1 Consignes générales de sécurité
Cet appareil est destiné à être utilisé uniquement avec des applications de
piscine à corps unique. Il ne doit pas être utilisé avec des applications de
piscine et de spa à deux corps, ou des spas autonomes. Tout travail en lien
avec l’électricité doit être effectué par un électricien qualifié, et se
conformer aux codes locaux, provinciaux et nationaux. Lors de l’installation
et de l’utilisation de cet équipement électrique, les consignes de sécurité
élémentaires doivent toujours être respectées, notamment les mises en garde
suivantes :
DANGER
SI CET ÉQUIPEMENT N’EST PAS INSTALLÉ ET UTILISÉ CORRECTEMENT, DES BLESSURES
CORPORELLES GRAVES OU LA MORT PEUVENT SURVENIR. LES INSTALLATEURS, LES
OPÉRATEURS DE PISCINE ET LES PROPRIÉTAIRES DE PISCINE DOIVENT LIRE TOUS LES
AVERTISSEMENTS, MISES EN GARDE ET INSTRUCTIONS AVANT D’UTILISER CET
ÉQUIPEMENT.
AVERTISSEMENT
AVANT D’UTILISER VOTRE PISCINE, VOTRE SPA OU VOTRE SPA, VÉRIFIER LES NIVEAUX
DE pH ET DE DÉSINFECTANT DE L’EAU.
AVERTISSEMENT
RISQUE D’EFFET VENTOUSE QUI, S’IL N’EST PAS ÉVITÉ, PEUT CAUSER DES BLESSURES
GRAVES, VOIRE MORTELLES. Ne pas bloquer l’aspiration de la pompe, ce qui
pourrait causer des blessures graves, voire mortelles. Ne pas utiliser cette
pompe pour les pataugeoires, les piscines peu profondes ou les spas disposant
de drains au fond, à moins que la pompe ne soit connectée à au moins deux (2)
prises d’aspiration fonctionnelles. Les ensembles d’aspiration (drains) et
leurs couvercles doivent être certifiés conformes à la dernière édition
publiée de la norme ANSI®/ASME® A112.19.8, ou sa norme ayant droit,
ANSI/APSP-16.
AVERTISSEMENT
Travailler avec des produits chimiques pour piscine peut être dangereux,
toujours porter des gants en caoutchouc et des lunettes de protection.
Toujours ajouter de l’acide à l’eau, ne pas ajouter l’eau à l’acide. Toujours
travailler dans un endroit bien aéré. Des éclaboussures ou des déversements
d’acide peuvent causer des blessures graves et/ou des dommages matériels.
Toujours suivre tous les avertissements, mises en garde et instructions de
manipulation du fabricant de produits chimiques. Lors du mélange, ne pas
oublier de toujours ajouter l’acide à l’eau.
AVERTISSEMENT NE PAS MÉLANGER L’HYPOCHLORITE DE SODIUM ET L’ACIDE MURIATIQUE.
AVERTISSEMENT
Au moment de mélanger l’acide et l’eau, TOUJOURS AJOUTER L’ACIDE À L’EAU. NE
JAMAIS AJOUTER L’EAU À L’ACIDE. Lire et suivre attentivement toutes les
instructions du fabricant de produits chimiques.
AVERTISSEMENT
Pour réduire les risques de blessures, ne pas laisser les enfants utiliser ce
produit.
AVERTISSEMENT
En raison du risque potentiel d’incendie, d’électrocution ou de blessures
corporelles, l’équipement Jandy doit être installé conformément au National
Electrical Code® (NEC®), NFPA 70 ou au Code canadien de l’électricité (CEC) à
tous les codes électriques et de sécurité locaux, ainsi que selon la loi
Occupational Safety and Health Act (OSHA). Il est possible de commander des
copies du NEC auprès de la National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02169, États-Unis, ou de votre agence
d’inspection du gouvernement. L’installation et le fonctionnement de cet
équipement doivent être conformes aux codes du bâtiment et de la santé
fédéraux, provinciaux et locaux.
PAGE 30
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
WARNING
DANGER Risque de blessure. A) Remplacer immédiatement le cordon endommagé.
B) Ne pas enfouir le cordon. C) Connecter à une prise mise à la terre
seulement.
AVERTISSEMENT
Une immersion prolongée dans l’eau chaude peut entraîner une hyperthermie.
L’hyperthermie survient lorsque la température interne corporelle monte de
plusieurs degrés au-dessus de la température normale corporelle de 37 °C (98,6
°F). Les symptômes comprennent des étourdissements, évanouissements,
somnolences, léthargies et une augmentation de la température corporelle
interne. Les effets de l’hyperthermie comprennent : · Inconscience de danger
imminent · Le défaut de percevoir la chaleur · Le défaut de reconnaître le
besoin de quitter le spa · L’incapacité physique de quitter le spa · Lésions
foetales chez la femme enceinte · Inconscience entraînant un risque de noyade
AVERTISSEMENT Pour réduire le risque de blessure · La température de l’eau
dans les spas ne doit jamais dépasser 40 °C (104 °F). La température de l’eau
entre 38 °C (100 °F) et 40 °C (104 °F) est considérée comme sécuritaire pour
un adulte en bonne santé. Une température d’eau inférieure est recommandée
pour les enfants et lorsque l’utilisation du spa dépasse 10 minutes. · Puisque
les températures de l’eau excessives ont un potentiel élevé d’endommager le
foetus pendant les premiers mois de la grossesse, les femmes enceintes ou qui
pensent l’être doivent limiter la température de l’eau du spa à 38 °C (100
°F). · Avant d’entrer dans un spa ou une cuve thermale, l’utilisateur devrait
vérifier la température de l’eau à l’aide d’un thermomètre précis, car la
tolérance des dispositifs de régulation de température de l’eau varie. · La
consommation d’alcool, de drogues ou de médicaments avant ou pendant
l’utilisation d’un spa ou d’une cuve thermale peut entraîner la perte de
conscience et la possibilité de noyade. · Les personnes obèses ou ayant des
antécédents médicaux de maladie du coeur, de diabète, de problèmes
circulatoires ou de pression sanguine irrégulière devraient consulter leur
médecin avant d’utiliser un spa. · Les personnes qui prennent des médicaments
devraient consulter un médecin avant d’utiliser un spa ou une cuve thermale,
car certains médicaments peuvent provoquer la somnolence, alors que d’autres
médicaments peuvent affecter la fréquence cardiaque, la tension artérielle et
la circulation.
AVERTISSEMENT · Les personnes atteintes de maladies infectieuses ne devraient
pas utiliser un spa ou une cuve thermale. · Pour éviter des blessures, faire
bien attention en entrant ou en sortant du spa ou de la cuve thermale. · Ne
pas consommer de drogues ou d’alcool avant ou pendant l’utilisation d’un spa
ou d’une cuve thermale afin
d’éviter la perte de conscience ou une possible noyade. · Les femmes enceintes
ou qui pensent l’être devraient consulter un médecin avant d’utiliser un spa
ou une cuve
thermale. · Une température de l’eau supérieure à 38 °C (100 °F) peut nuire à
votre santé. · Avant d’entrer dans un spa ou une cuve thermale, vérifier la
température de l’eau à l’aide d’un thermomètre
précis. · Ne pas utiliser un spa ou une cuve thermale immédiatement après
avoir pratiqué une activité physique intense. · L’immersion prolongée dans un
spa ou une cuve thermale peut être nuisible à votre santé. · Ne pas permettre
l’utilisation d’appareil électrique (comme une lampe, un téléphone, un radio
ou une télévision)
à moins de 1,5 m (5 pi) d’un spa ou d’une cuve thermale. · L’utilisation de
l’alcool, des drogues ou des médicaments peut augmenter considérablement le
risque
d’hyperthermie mortelle dans les spas ou les cuves thermales.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 31
AVERTISSEMENT
RISQUE DE DÉCHARGE ÉLECTRIQUE, D’INCENDIE, DE BLESSURES OU DE MORT. (Pour tout
équipement installé de façon permanente et destiné à être utilisé sur des
circuits de dérivation monophasés de 15 ou 20 a, 120 à 240 V). Raccorder
uniquement à un circuit de dérivation qui est protégé par un disjoncteur de
fuite à la terre (DDFT) pour le personnel. Contacter un électricien qualifié
s’il n’est pas possible de vérifier que le circuit est équipé d’un
différentiel ou non. Un tel DDFT doit être fourni par l’installateur et faire
l’objet d’essais régulièrement. Pour tester le différentiel, appuyer sur le
bouton de test. Le différentiel doit couper le DDFT de l’alimentation. Appuyer
sur le bouton de remise en route. L’alimentation doit être rétablie. Si le
DDFT ne fonctionne pas comme indiqué, c’est qu’il est défectueux. Si le
différentiel coupe l’alimentation de la pompe sans que le bouton de test ait
été enfoncé, cela indique la présence d’un courant de terre, signifiant un
risque de décharge électrique. Ne pas utiliser l’appareil. Débrancher
l’appareil et faire corriger le problème par un représentant de service
qualifié avant toute utilisation. DÉBRANCHER TOUTES LES CONNEXIONS
D’ALIMENTATION AVANT DE RÉPARER CET ÉQUIPEMENT. Toujours débrancher toujours
l’alimentation au disjoncteur avant l’entretien. Le non-respect de cette
consigne peut entraîner des blessures graves ou la mort.
AVERTISSEMENT
Cet appareil est destiné à être utilisé uniquement avec des applications de
piscine à corps unique. Il ne doit pas être utilisé avec des applications de
piscine et de spa à deux corps, ou des spas autonomes. L’utilisation de ce
produit avec des applications de piscine et de spa à double corps ou des spas
autonomes peut entraîner des blessures graves, des dommages matériels et
annuler la garantie.
AVERTISSEMENT
Un équipement mal installé peut tomber en panne et causer des blessures
graves, des dommages matériels et peut annuler la garantie. NE PAS MODIFIER
CET ÉQUIPEMENT.
AVERTISSEMENT
Ne pas raccorder le système à un réseau municipal d’approvisionnement en eau
non régulé ni à aucune autre source externe d’eau sous pression produisant des
pressions supérieures à 2,41 BAR (35 PSI).
AVERTISSEMENT Pour réduire le risque de blessures graves ou de décès, cet
équipement ne doit pas être soumis à un essai de mise sous pression de la
tuyauterie. Les codes locaux peuvent exiger l’application d’un test de mise
sous pression au niveau de la tuyauterie de la piscine. Généralement, ces
exigences ne sont pas conçues pour être appliquées à l’équipement de piscine,
comme les filtres ou les pompes. L’équipement de piscine Zodiac® est soumis à
des tests de mise sous pression en usine. Toutefois, si cet AVERTISSEMENT ne
peut pas être respecté et que le test de mise sous pression du système de
tuyauterie doit inclure le filtre et/ou la pompe, S’ASSURER DE RESPECTER LES
CONSIGNES DE SÉCURITÉ SUIVANTES : · Vérifier les serre-joints, les boulons,
les couvercles, les anneaux de blocage et les accessoires du système pour
s’assurer
qu’ils sont correctement installés et fixés solidement avant d’effectuer un
test.
· LIBÉRER TOUT L’AIR présent dans le système avant le test.
· La pression de l’eau pendant le test NE DOIT PAS DÉPASSER 2,41 BAR (35 lb-
po²).
· La température de l’eau pendant le test NE DOIT PAS DÉPASSER 38 °C (100 °F).
· Limiter la durée du test à 24 heures. Après le test, vérifier visuellement
le système pour s’assurer qu’il est prêt à fonctionner.
AVIS : ces paramètres s’appliquent à l’équipement Zodiac uniquement. Pour les
équipements autres queZodiac, consulter le fabricant de l’équipement.
AVERTISSEMENT
Les déversements de produits chimiques et les émanations peuvent affaiblir
l’équipement de piscine/spa. La corrosion peut provoquer la panne des filtres
et d’autres équipements, entraînant ainsi de graves blessures ou des dommages
matériels. Ne pas ranger les produits chimiques à proximité de votre
équipement.
MISE EN GARDE
Ne pas installer dans une enceinte extérieure ou sous les bords d’une cuve
thermale.
MISE EN GARDE
Afin d’éviter une défaillance prématurée ou des dommages à l’équipement, le
protéger de l’exposition directe à l’eau provenant des gicleurs, du
ruissellement des toits et du drainage, etc. Le non-respect de cette consigne
peut entraîner une défaillance de l’équipement et peut également annuler la
garantie.
PAGE 32
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
AVERTISSEMENT
Les déversements de produits chimiques et les émanations peuvent affaiblir
l’équipement de piscine/spa. La corrosion peut provoquer la panne des filtres
et d’autres équipements, entraînant ainsi de graves blessures ou des dommages
matériels. Ne pas ranger les produits chimiques à proximité de votre
équipement.
DANGER
LIRE CE QUI SUIT AVANT DE MANIPULER ET DE TRAVAILLER AVEC DE L’ACIDE
MURIATIQUE (AUSSI CONNUE SOUS LE NOM D’ACIDE CHLORHYDRIQUE) ET DU CHLORE
(CHLORHYDRATE DE SODIUM)
L’ACIDE MURIATIQUE ET LE CHLORE (LIQUIDE ET BRUME) PEUVENT PROVOQUER DES
BRÛLURES GRAVES À LA PEAU, LA BOUCHE ET LES YEUX. PEUT ÊTRE MORTEL EN CAS
D’INGESTION OU D’INHALATION. L’INHALATION PEUT CAUSER DE GRAVES LÉSIONS
POUMONS. IMPORTANT! RÉCIPIENT À CHLORE
LE MÉLANGE DE PRODUITS CHIMIQUES AVEC DU CHLORE OU DES RÉSIDUS DE CHLORE DANS
UN RÉCIPIENT PEUT CRÉER UN GAZ MORTEL OU UNE EXPLOSION.
AVERTISSEMENT
INHALATION
L’inhalation de vapeurs peut provoquer une toux, une inflammation du nez, de
la gorge et des voies respiratoires supérieures et la mort. En cas
d’inhalation, se déplacer immédiatement dans une zone d’air frais.
INGESTION
La déglutition peut être fatale. Contacter immédiatement le centre antipoison
local ou un médecin. Faire boire de grandes quantités d’eau ou de lait.
Laisser la personne vomir. En cas de vomissement, garder la tête plus basse
que les hanches pour éviter l’aspiration. Si la personne est inconsciente,
tourner la tête sur le côté. Consulter immédiatement un médecin.
ENTREPOSAGE
Installer et stocke le récipient et l’acide dans un endroit sec et aéré, à
l’abri de la chaleur excessive et de la lumière directe du soleil. Doit être
conservé à une température inférieure à 80 °F (27 °C). S’assurer que le
drainage est situé loin du bâtiment et de l’équipement.
CONTACT CUTANÉ
Laver la peau à l’eau et au savon pendant au moins 20 minutes et retirer les
vêtements et chaussures contaminés. Les vêtements contaminés doivent être
soigneusement nettoyés avant réutilisation.
CONTACT OCULAIRE
Rincer les yeux immédiatement avec de l’eau pendant au moins 20 minutes.
Consulter immédiatement un médecin.
PROTECTION INDIVIDUELLE
VENTILATION
Utiliser le contenant à l’extérieur et dans un endroit bien ventilé.
PROTECTION OCULAIRE
Porter des lunettes de sécurité résistantes aux éclaboussures.
VÊTEMENTS
Porter des vêtements résistants aux produits chimiques lors de la manipulation
ou le travail avec de l’acide et du chlore.
GANTS
Porter des gant résistants aux produits chimiques lors de la manipulation ou
le travail avec de l’acide et du chlore.
ÉLIMINATION
En raison de sa nature corrosive, l’acide muriatique est un déchet dangereux
lorsqu’il est renversé ou jeté. Éliminer l’acide usagé dans une installation
de gestion des déchets dangereux agréée ou un installation municipale de
collecte des déchets dangereux ménagers. Les petits déversements d’acide
peuvent être neutralisés à l’aide de bicarbonate de soude. Verser délicatement
le bicarbonate de soude sur le matériau déversé jusqu’à ce que le pétillement
s’arrête, puis éponger ou ramassez les résidus. Confier le nettoyage des
déversements importants aux experts : appeler le service d’incendie local ou
l’équipe de déversement de matières dangereuses.
CONSERVER CES DIRECTIVES
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 33
Section 2. Pour commencer
Ce manuel procure des instructions pour l’installation et l’utilisation du
contrôleur des produits chimiques TruDose
Lire les instructions d’installation et d’utilisation au complet avant de
procéder à l’installation. Conservez le présent manuel dans un endroit sûr
pour référence ultérieure.
2.1 Composants du système
2.1.1
Contrôleur des produits chimiques TruDose
Le contrôleur de produits chimiques TruDose permet une surveillance et un ajustement automatiques des niveaux de pH et d’ORP (le réglage nécessite un chlorateur d’eau salée en option connecté) via une interface simple et conviviale, ce qui facilite la gestion de l’équilibre de l’eau dans les piscines.
Il peut être facilement installé dans votre environnement et équipement de
piscine existants et surveille et affiche les niveaux de pH et de redox à
l’aide de DEL et d’affichages numériques sur le panneau avant de l’appareil.
De plus, quatre
boutons de fonction séparés permettent un contrôle simple par
bouton-poussoir de ces paramètres individuels :
· Mode – Auto (en cours d’exécution), paramètres de pH, paramètres de redox.
· Niveau défini – le niveau de pH ou d’ORP doit être maintenu.
· Durée de dosage – Durée de dosage (secondes) pour le pH. Temps de suralimentation (heures) pour l’ORP.
· pH Cal – Étalonnage du pH pour la variation des capteurs de pH
Le contrôleur a une pompe péristaltique qui alimente l’acide liquide. La pompe
à acide se mettra en marche si le pH mesuré est supérieur à la consigne
définie par l’utilisateur.
Lorsque l’ORP mesuré par la sonde ORP est inférieur au point de consigne
défini par l’utilisateur, le contrôleur active la chloration à partir du
chlorateur d’eau salée en option pour produire du chlore et atteindre l’ORP
souhaité. Lorsque l’ORP atteint le point de consigne, le contrôleur chimique a
la capacité de désactiver la chloration du chlorateur d’eau salée. Le
chlorateur d’eau salée n’est pas fourni avec le contrôleur des produits
chimiques TruDose.
2.1.2 Cellule de débit avec interrupteur de débit
La cellule de débit abrite un interrupteur de débit et contient les capteurs
de pH et de redox. Ces capteurs se connectent au contrôleur des produits
chimiques pour surveiller les niveaux de pH et d’ORP dans l’eau.
L’interrupteur de débit vérifie que l’eau s’écoule pendant un cycle
d’alimentation et envoie au contrôleur des instructions pour désactiver
l’alimentation si l’eau ne s’écoule pas. Le fonctionnement de ce contrôleur
sans interrupteur de débit
fonctionnel peut entraîner un sous-dosage ou un surdosage de produits chimiques.
2.1.3 Autres composants
· Capteur de pH – standard (utiliser uniquement le numéro de pièce R0894300)
· Capteur ORP Gold – standard (utiliser uniquement le numéro de pièce R0894400)
· Raccords – pour l’installation de taraudage de l’entrée/ sortie de la cellule à écoulement
· Filtre en ligne – installer avant la cellule à écoulement pour protéger le commutateur de débit et les capteurs de pH et de redox.
· Tube – 25 pieds de 3/8 po et 20 pieds de 1/4 po pour fournir de l’acide vers et depuis le réservoir d’acide.
· Pompe à pH – y compris les tubes et les raccords – pompe péristaltique intégrée pour l’acide de contrôle du pH.
· Panneau de montage – Plastique ABS avec trous de montage et quincaillerie en acier inoxydable (18 po x 10 po).
· Taraud 1/4 po NPT (inclus)
REMARQUE : L’utilisation d’acide non dilué peut entraîner des problèmes de corrosion ou de suralimentation. Utiliser uniquement de l’acide chlorhydrique (non fourni). Diluer l’acide au ratio de 4:1 en suivant les recommandations de sécurité du fabricant de produits chimiques et utiliser un équipement de protection individuelle. Par exemple : Pour un réservoir de 5 gallons, il y aurait 4 gallons d’eau et 1 gallon d’acide muriatique.
Trousse R TruDose
1
R0894300 CAPTEUR pH
2
R0894400 CAPTEUR ORP
3
R0944100 REMPLACEMENT PCBA
4
R0944300 CÂBLE D’ALIMENTATION
5
R0944400 CONTRÔLEUR SEULEMENT
6
R0944500 TUBE POLY NOIR 1/4 PO
(ROULEAU 25 PIEDS)
7
R0944600 TUBE POLY NOIR 3/8 PO
(ROULEAU 28 PIEDS)
8
R0944900 CELLULE DE DÉBIT AVEC
INTERRUPTEUR DE DÉBIT, VANN,
RACC10
9
R0945000 FILTRE EN LIGNE AVEC CRÉPINE
ET RACCORDS
10 R0945100 INTERRUPTEUR DE DÉBIT
11 R0945200 TUBES À PRESSER (2 PAQ)
12 R0945300 TROUSSE ACCESSOIRE POMPE
13 R0945400 POMPE ACIDE PÉRISTALTIQUE
14 R0961700 TROUSSE ASSEMBLAGE ROULEAU DE POMPE
15 R0962100 TRUDOSE INT CÂBLE 24 V. c.c.
PAGE 34
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
Installation typique
REMARQUE : Tous les produits chimiques doivent être injectés en aval du
réchauffeur et de la cellule de débit.
*REMARQUE : Monter le transformateur d’alimentation électrique à 30 cm (1 pi) au-dessus du sol.
Prise extérieure étanche protégée par DDFT
ORP pH
pH 7,2-7,6
Cellule de débit
ORP 600-800 mV
Pompe
Filtre
*Voir Note
Réchauffeur
De la piscine
Soupape antiretour
Retour du spa
Not Cap
Do
Cellule AquaPure Retour de la piscine
Figure 1. Installation hydraulique typique d’un contrôleur des produits chimiques TruDose
1 Échantillon d’eau à la cellule de débit 2 Retour d’eau de la cellule de
débit 3 Introduction d’acide
1
3 Réchauffeur
Filtre
Cellule avec capteur de débit/Temp./Salinité Retour de la piscine
Figure 2. Connexion cellule de débit – Vue de haut
AquaPure® Contrôle Centre
Ou
PureLink Centre
électrique
TruClear® XL Ou
Cellule de débit Contrôleur TruDose
Pompe
pH 7,2-7,6 ORP 600-800 mV
2
Admission piscine
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 35
2.2 Spécifications
Dimensions du système Entrée/sortie électrique Niveau réglé du pH
L 8 po x l 10 po x P 6,5 po
Entrée : 100/240 V. c.a. ~ 50/ 60 Hz 0,6 Hz Sortie : 24 V. c.c. – 1 000 mA 24
W (Alimentation électrique fournie)
7,0 à 8,0
Niveau réglé de l’ORP 400 mV à 900 mV
Minuterie de dose pH Cycle arrêté ou minuté
Alerte faible
pH 6,9, ORP 390 mV
Alerte élevée
Lecture
Alertes (bas ou haut) Alarme de suralimentation pH Alarme de suralimentation
ORP
pH 8,1, ORP 910 mV
DEL fonctionnelle et affichages numériques qui alternent entre le pH et l’ORP
(mV)
DEL d’alerte rouge – fixe
– Alerte DEL pH clignotante – Er1 affiché sur l’écran ACL – DEL d’alerte ORP
clignotante – Er2 affiché sur l’écran ACL
2.3 Descriptions du panneau de commande
2.3.1 Affichages numériques et DEL de fonction a. pH La valeur de pH mesurée
est affichée sur l’écran ACL.
· Alerte pH (bas ou haut) – DEL rouge fixe
· Alarme de suralimentation pH – DEL rouge clignotante et « Er1 » affiché sur
l’écran ACD
· Dose pH – en marche – DEL verte clignotante
· Dose pH – temps d’arrêt – DEL verte fixe b. ORP La valeur ORP mesurée est
affichée en millivolts (mV) et affichée sur l’écran ACL. (en alternance avec
le pH).
· Alerte ORP (bas ou haut) – DEL rouge fixe
· Alarme de suralimentation ORP – DEL rouge clignotante et « Er2 » affiché sur
l’écran ACL
· Dosage Redox – minuterie allumée – DEL verte clignotante
Mode – ajustements de bouton-poussoir · Auto – DEL Rouge · Réglages pH – DEL
verte · Réglages ORP – DEL jaune · Mode arrêté – en attente, appuyer et tenir
bouton mode 3
secondes pour arrêter le contrôleur.
Pompe péristaltique pour acide
Communication du contrôleur Affichage numérique Bouton-poussoir Voyants DEL
Capteur pH
Interrupteur
de débit
Alimentation
Contrôle de la
Capteur électrique
chloration
ORP
eau salée
Figure 3. Connexions du contrôleur
· Débit – DEL verte · Niveau de réglage – ajustements de bouton-poussoir
(monter/baisser) · Durée de dose – ajustements de bouton-poussoir (monter/
baisser) · Cal pH – ajustements de bouton-poussoir (monter/baisser) 2.3.2
Connexions électriques (périphériques) · Alimentation électrique c.a. – 100 à
240 V. c.a. , 50-60 Hz · Interrupteur de Débit – de la cellule de débit ·
Capteur pH (bleu) – Connexion BNC · Capteur ORP (rouge) – Connexion BNC ·
Contrôle chlorateur d’eau salée – 24 V. c.c.
PAGE 36
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
2.4 Connexion du contrôleur chimique TruDose à un chlorateur d’eau salée Jandy
en option
AVERTISSEMENT
Débrancher l’alimentation du TruDose avant l’entretien en débranchant
l’alimentation électrique au niveau de la prise.
2.4.1 Connexion du contrôleur chimique TruDose au chlorateur d’eau salée Jandy
AquaPure®
Le contrôleur chimique TruDose est compatible avec le chlorateur d’eau salée
Jandy AquaPure. Cela inclut les blocs d’alimentation APUREM, FUSIONM et
PURELINK.
Lorsque la lecture de TruDose ORP est inférieure au point de consigne, le
câble 24 V. c.c. commandera au chlorateur d’eau salée d’activer la chloration.
Le chlorateur commencera à produire du chlore. L’interface utilisateur de
l’électrolyseur affichera le taux de production de 0 % à 100 % de sortie de
chlore.
Lorsque la lecture TruDose ORP est supérieure au point de consigne, le câble
24 V. c.c. commandera au chlorateur d’eau salée d’arrêter la chloration.
L’électrolyseur ne produira pas de chlore et l’interface utilisateur de
l’électrolyseur affichera « EC » (contrôle externe) clignotant.
Pour connecter le TruDose Chemical Controller à un électrolyseur d’eau salée
Jandy, il faut connecter le câble 24 V. c.a. préinstallé du TruDose Chemical
Controller à la carte d’interface d’alimentation (PIB) dans le bloc
d’alimentation du chlorateur d’eau salée. Le cavalier ORP sur la carte PIB du
bloc d’alimentation du chlorateur d’eau salée devra être déplacé vers la
position 2. Se reporter à la Figure 6 pour obtenir des instructions sur la
manière de déplacer le cavalier
ORP en position 2 sur le PIB du bloc d’alimentation.
Figure 5. Centre d’alimentation AquaPure® (APUREM)
MISE EN GARDE Avant d’effectuer ces tâches, couper l’alimentation au
disjoncteur principal pour éviter le risque de décharge électrique pouvant
entraîner des dommages matériels, des blessures graves ou la mort.
Le cavalier ORP par défaut vient de l’usine en position 1.
1. Retirer le cavalier ORP J14 de la carte.
2. Déplacer le cavalier ORP des deux broches du bas vers les deux broches du
haut. Se reporter à la Figure 6.
3. Connecter le câble 24 V. c.c. du TruDose au connecteur J15 2 broches du
centre d’alimentation PIB AquaPure. Se reporter à la Figure 6.
REMARQUE : Le fil noir doit être connecté à droite et le rouge à gauche.
Connecteur ORP J15 R0474300
Fils au contrôleur ORP externe
Noir
Rouge
Câble 24 V. c.c.
Figure 4. Connexion du contrôleur TruDose 24 V. c.c.
Monter cavalier
J2
J14 ORP
J2
Interface d’alimentation du générateur de chlore
Figure 6. Connexion ORP
4. La connexion RS-485 peut rester pour fournir des informations AquaPure, y
compris la concentration en sel, l’état et les changements de pourcentage de
production via l’application iAquaLink.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 37
2.4.2
Connexion du contrôleur chimique TruDose au chlorateur d’eau salée Jandy TruClear®
MISE EN GARDE
Avant d’effectuer ces tâches, couper l’alimentation au disjoncteur principal
pour éviter le risque de décharge électrique pouvant entraîner des dommages
matériels, des blessures graves ou la mort.
6. Déplacer le cavalier ORP sur la carte d’interface d’alimentation (PIB) du centre d’alimentation TruClear XL de la position 1 (par défaut) à la position 2.
1. Percer le trou inférieur gauche (situé dans la section basse tension) au
bas du bloc d’alimentation TruClear XL.
2. Installer la bague fournie avec le bloc d’alimentation TruClear XL dans le
trou de perforation.
Câble 24 V. c.c. à TruDose
Câble RS-485
Figure 7. Communication/connexion d’alimentation TruClear XL
3. Retirer le connecteur avec un tournevis à tête plate qui se trouve à
l’extrémité du câble TruDose 24 V.c.c.
REMARQUE : La connexion RS-485 doit être supprimée pour activer le contrôle
ORP via le système TruClear XL avec les informations fournies via
l’application iAquaLink.
Retirer le connecteur du câble 24 V c.c. déjà installé
Câble 24 V c.c. du contrôleur TruDose
Descendre Cavalier J17 ORP
Connecteur J16 ORP
Figure 9. Centre d’alimentation PIB TruClear XL
REMARQUE : « EC » s’affichera sur l’électrolyseur d’eau salée lorsque la chloration est désactivée. Une fois l’unité allumée, le générateur de chlore ne répondra aucun changement pendant la première minute de fonctionnement. L’appareil peut sembler BLOQUÉ EN mode « EC ». Attendre quelques minutes jusqu’à ce que l’unité se soit réchauffée pour vérifier que le chlorateur a répondu à la mise en marche.
REMARQUE : Plusieurs générateurs de chlore peuvent être reliés entre eux pour être contrôlés avec un seul contrôleur ORP sans utiliser de relais et de transformateurs externes. Contacter l’usine pour plus d’informations.
Position du cavalier ORP J14 / J17
POS 1* (défaut)
- Ne contrôlera pas correctement le chlorateur
POS 2 (nécessaire avec TruDose)
24 V. c.c.
Unité éteinte affiche EC sur le chlorateur
Unité ON – affiche 0-100 % sur le chlorateur
0 V. c.c.
Unité ON – affiche 0-100 % sur le chlorateur
Unité éteinte affiche EC sur le chlorateur
Figure 8. Câble 24 V. c.c. TruDose
4. Insérer le câble TruDose 24VDC à travers le trou de perforation
nouvellement installé et la bague au bas du bloc d’alimentation TruClear XL.
5. Installer les 2 broches du câble TruDose 24 V. c.c. sur le connecteur ORP
J16 situé sur la carte d’alimentation TruClear XL. Le haut du connecteur est
amovible pour faciliter l’installation.
J14 = emplacement du cavalier ORP sur la carte AquaPure. Doit monter à la
position 2.
J15 = emplacement du connecteur ORP sur la carte AquaPure. Insérer le câble 24
V. c.c. ici.
J16 = emplacement du connecteur ORP sur la carte XL TruClear. Insérer le câble
24 V. c.c. ici.
J17 = emplacement du cavalier ORP sur la carte XL TruClear. Doit descendre à
la position 2.
PAGE 38
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
Section 3. Installation
3.1 Configuration
1. Éteindre tous les équipements périphériques tels que les radiateurs et les
pompes.
2. Relâcher la pression du système de filtration.
3.2 Outils
· Perceuse sans fil · Taraud 1/4 po NPT (fourni) · Foret 7/16 po · Foret à
maçonnerie et ancrages ou autres éléments de
fixation appropriés. · Clé de 13/16 po ou pince à verrouillage de canal ·
Couvercle de sortie étanche pour les installations
extérieures
3.3 Bloc d’alimentation
· Le contrôleur des produits chimiques TruDose doit être connecté à une sortie
extérieure étanche protégée par un disjoncteur de fuite de terre.
· Ne pas utiliser de rallonges. · L’alimentation doit être installée à au
moins 1 pi
(30 cm) au-dessus de la surface du sol. S’assurer que l’alimentation
électrique est protégée de l’exposition directe à l’eau des gicleurs, du
ruissellement de l’eau des toits et du drainage.
ATTENTION Le contrôleur doit être alimenté uniquement avec le courant fourni
et connecté à un circuit électrique dédié protégé par GFCI, classe A GFCI au
Canada. Aucun autre équipement, lumière, appareil ou prise ne doit être
connecté au circuit du contrôleur.
3.4 Installation du contrôleur
3.4.1 Emplacement
· Zone murale avec un accès facile · À au moins 5 pieds (1,5 m)
horizontalement du bord de la
piscine et/ou du spa. Au Canada, à au moins 3 mètres (10 pieds)
horizontalement du bord de la piscine et/ou du spa. · À moins de 15 pieds de
la source d’alimentation DDFT
MISE EN GARDE
Afin d’éviter une défaillance prématurée ou des dommages au contrôleur
protéger de l’exposition directe à l’eau provenant des gicleurs, du
ruissellement des toits et du drainage, etc. Le non-respect de cette consigne
peut entraîner une défaillance du contrôleur et peut également annuler la
garantie.
· Le contrôleur TruDose doit être installé à au moins 2 pieds (0,6 m) à la
verticale de la surface du sol. S’assurer que le contrôleur est protégé de
l’exposition directe à l’eau des gicleurs, du ruissellement de l’eau des toits
et du drainage.
3.4.2 Montage
REMARQUE : Le contrôleur et la cellule de débit sont montés en usine sur la
carte ABS pour votre commodité.
1. Monter solidement la carte de montage ABS avec le contrôleur chimique et
la cellule à débit sur le mur.
2. Percer un trou de 7/16 po et appuyez sur un orifice NPT de 1/4 po à un
emplacement en aval du filtre et en amont de tout élément chauffant ou point
d’introduction de produits chimiques. Installer un connecteur de tube (inclus)
et un tube flexible de 3/8 po à connecter au port de la cellule à écoulement
du côté gauche contenant le commutateur de débit. Le filtre en ligne sera
également installé dans cette ligne dans un endroit facilement accessible.
REMARQUE : Vérifier que le filtre en ligne est installé avec des flèches
directionnelles pointant dans le sens du flux (vers la cellule de débit).
3. Percer un trou de 7/16 po et tarauder un orifice NPT de 1/4 po à un
endroit soumis au vide ou à une pression réduite. Installer un connecteur de
tube (inclus) et un tube flexible de 3/8 po à connecter au port de la cellule
à écoulement du côté droit.
REMARQUE : Nous vous recommandons d’installer ce connecteur de tube dans le
trou de vidange du côté aspiration de la pompe pour de meilleures
performances.
4. Couper 3 po à 6 po de longueur de tube flexible de 3/8 po et l’insérer
dans le port de flux d’échantillon de la cellule de débit (centre).
3.5 Installation capteurs pH et ORP
REMARQUE : Déballer soigneusement les capteurs de pH et de redox et les mettre
de côté dans un endroit dégagé jusqu’à ce qu’ils soient prêts à être installés
dans la cellule de débit.
1. Vérifier que le contrôleur est hors tension. 2. Retirer soigneusement le
conteneur de protection en
plastique des capteurs et le ranger dans un endroit séparé pour une
réutilisation future. 3. Desserrer (ne pas retirer) l’écrou supérieur des
raccords à compression en haut de la cellule de débit et faire glisser avec
précaution l’extrémité en verre de chaque capteur (pH et redox) dans les
raccords à compression. S’assurer que la pointe est immergée dans l’eau à
moins de 1/2 po du bas de la cellule de débit. Serrer chaque écrou à la main.
Ne pas utiliser des outils pour compresser les raccords. 4. Branchements
électriques · Vérifier que le contrôleur est éteint.
· Connecter le connecteur du capteur de pH (bleu) au connecteur BNC gauche en
bas du contrôleur.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 39
· Connecter le capteur ORP (rouge) au connecteur BNC droit en bas du
contrôleur.
· Brancher l’alimentation dans la prise protégée par GFCI (les installations
extérieures doivent avoir des boîtiers résistants aux intempéries installés).
REMARQUE : Continuer à surveiller l’absence de chlore par des tests manuels
afin de garantir des niveaux sanitaires adéquats.
3.6 Installation de la pompe de produits chimiques
AVERTISSEMENT
RISQUE DE BRÛLURE CHIMIQUE : S’assurer que toutes les pompes sont éteintes au
niveau des disjoncteurs principaux de la maison avant de percer des tuyaux.
Fixer solidement toutes les conduites électriques, d’eau et de produits
chimiques. Placer les pompes d’alimentation en produits chimiques et les
réservoirs de stockage de produits chimiques dans un endroit sûr et sécurisé.
3.6.1
Liste de vérification des accessoires de la pompe
· Trois (3) écrous de raccordement 1/4 po · Trois (3) viroles 1/4 po · Un (1)
clapet antiretour d’injection · Une (1) crépine de conduite d’aspiration
pondérée 1/4 po · Un (1) rouleau de 20 pi de tube d’aspiration/évacuation
noir 1/4 po
3.6.2
Avertissements de sécurité pour pompe de produits chimiques
1. Lire tous les risques liés à la sécurité avant d’installer ou de faire l’entretien des pompes. La pompe est conçue pour l’installation et l’entretien par un personnel adéquatement formé.
2. Porter l’équipement de protection individuelle résistant aux produits chimiques requis lors d’un travail sur ou à proximité d’une pompe de dosage.
3. Installer la pompe de manière à ce qu’elle respecte tous les codes de plomberie et d’électricité nationaux et locaux.
4. Utiliser le produit approprié pour traiter les systèmes d’eau de piscine et n’utiliser que des additifs répertoriés ou approuvés pour une utilisation.
5. Inspecter fréquemment les tubes pour détecter toute fuite, détérioration ou usure. Programmer un changement d’entretien régulier de la tubulure de la pompe pour éviter d’endommager les pompes et/ou les déversements.
6. Les pompes ne sont pas recommandées pour une installation dans des zones où les fuites peuvent causer des blessures ou des dommages matériels.
Vue démontée de la soupape antiretour d’injection
Bec de canard
Sens de débit de la solution
Conduite d’évacuation
Clapet antiretour d’injection
Vue démontée d’écrou et virole
Conduite d’aspiration
Figure 10. Diagramme d’installation de la pompe de produits chimiques
NE PAS utiliser de ruban Téflon sur les filets de la pompe ou du tube
NE PAS utiliser de pinces
Serrer l’écrou à la main
Conduite d’évacuation
Vue démontée d’écrou et virole
Ferrules Remarque : Extrémités coniques de viroles de pompe. La tuyauterie
doit être au fond de tous les raccordements.
Conduite d’aspiration
Figure 11. Installer la conduite d’aspiration à la tête de la pompe
3.6.3 Conduite d’aspiration à la tête de la pompe 1. Dérouler la conduite
d’aspiration/évacuation. Utiliser
en dehors du réservoir à solution comme guide pour couper les bonnes longueurs
de conduite d’aspiration, en s’assurant d’avoir 2 à 3 po au dessus du
réservoir à solution.
REMARQUE : Laisser suffisamment de mou pour éviter les plis et les fissures de
contrainte. Toujours faire une coupe carrée propre pour vous assurer que la
conduite d’aspiration est exempte de bavures. L’entretien normal nécessite une
taille.
REMARQUE : Les conduites d’aspiration qui s’étendent jusqu’au fond du
réservoir peuvent entraîner un ramassage de débris conduisant à des injecteurs
obstrués et à une défaillance possible du tube.
2. Effectuer les connexions en faisant glisser la ou les conduites dans les
écrous et les viroles de connexion et serrer à la main sur les raccords de
tube correspondants.
3. Serrer l’écrou à la main sur le raccord de tube fileté tout en maintenant
le raccord de tube.
PAGE 40
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
REMARQUE : Un serrage excessif de la virole et de l’écrou avec une clé peut
endommager les raccords, écraser les viroles et entraîner une prise d’air.
REMARQUE : NE PAS utiliser de ruban d’étanchéité pour filetage sur les
raccords de tube de pompe ou d’outils pour serrer les raccords.
3.6.4 Poids d’aspiration à la ligne d’aspiration
1. Percer un trou dans le bouchon de bonde ou le couvercle du réservoir de
solution. Faire glisser le tube à travers et fixer la crépine lestée à la
ligne.
2. Pour fixer la crépine, pousser environ 3,5 po de conduite d’aspiration à
travers le capuchon sur le corps de la crépine. Tirer sur le tube pour vous
assurer qu’il est bien fixé.
3. Suspendre légèrement au-dessus du fond du réservoir pour réduire le risque
d’accumulation de sédiments.
REMARQUE : NE PAS mélanger d’additifs dans le récipient de solution. Suivre
les procédures de mélange recommandées selon le fabricant.
3. Enrouler l’extrémité mâle NPT (MNPT) du raccord d’injection avec 2 ou 3
tours de ruban à fileter. Si nécessaire, couper le manchon du raccord
d’injection selon les besoins pour injecter le produit directement dans le
flux d’eau.
4. Serrer à la main le raccord d’injection dans le raccord FNPT.
5. Installer l’écrou de raccordement et la virole sur le tuyau de refoulement
de la pompe. Insérer le tube de décharge dans le raccord d’injection jusqu’à
ce qu’il atteigne la base du raccord.
6. Serrer à la main l’écrou de raccordement au raccord.
7. Allumer la pompe et remettre le système sous pression. Observer le débit
tel qu’il est actionné par le système et vérifier que toutes les connexions
sont étanches.
8. Après une durée de dosage appropriée, effectuer un test pour les lectures
souhaitées. Si nécessaire, affiner les niveaux de dosage.
REMARQUE : Le point d’injection et le raccord nécessitent un entretien
périodique pour nettoyer tout dépôt ou accumulation. Pour permettre un accès
rapide au point d’injection, nous recommandons l’installation de vannes
d’arrêt.
25,4 cm (3,5 po) (9 cm)
Conduite d’aspiration
Crépine de conduite
d’aspiration pondérée
25,4 cm (3 po)
NE PAS utiliser de ruban Téflon sur les filets de la pompe ou du tube
Couper l’extrémité du raccordement d’injection
NE PAS utiliser de pinces
Figure 12. Installer un poids d’aspiration à la ligne d’aspiration
3.6.5
Conduite de refoulement vers la tête de pompe et le point d’injection
1. Effectuer une connexion sécurisée à la main sur le raccord de refoulement de la tête de pompe comme indiqué dans la section Instructions d’installation de la conduite d’aspiration.
REMARQUE : NE PAS utiliser de ruban d’étanchéité pour filetage sur les raccords de tube de pompe ou d’outils pour serrer les raccords.
AVERTISSEMENT
PRESSION DANGEREUSE : Couper l’eau ou la circulation et purger la pression du
système.
REMARQUE : Localiser un point d’injection au-delà de toutes les pompes et
filtres ou tel que déterminé par l’application.
2. Une connexion 1/4 po ou 1/2 po femelle NPT (FNPT) est requise pour
l’installation du raccord d’injection. Si aucun raccord FNPT n’est disponible,
en fournir un soit en taraudant le tuyau ou en installant un raccord en T de
tuyau FNPT.
Point d’injection typique
Soupape d’injection
Do
Not Cap
soupape antiretour
Conduite de retour
Figure 13. Installer la conduite de refoulement vers la tête de pompe et le point d’injection
REMARQUE : L’utilisation d’acide non dilué peut entraîner des problèmes de corrosion ou de suralimentation. Utiliser uniquement de l’acide chlorhydrique (non fourni). Diluer l’acide au ratio de 4:1 en suivant les recommandations de sécurité du fabricant de produits chimiques et utiliser un équipement de protection individuelle. Par exemple : Pour un réservoir de 5 gallons, il y aurait 4 gallons d’eau et 1 gallon d’acide muriatique.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et
de fonctionnement
3.7 Mise à la terre
Le National Electrical Code® (NEC® aux États-Unis) ou le Code canadien de
l’électricité (CEC au Canada) exige des pièces métalliques de l’équipement
électrique associé à la circulation de l’eau de la piscine et des pièces
métalliques fixes à moins de 5 pieds de la paroi de la piscine aux États-Unis,
10 pi pour le Canada, à coller les uns aux autres. Vérifier les codes locaux
pour déterminer si les autorités compétentes (AHJ aux États-Unis) ou les
autorités compétentes au Canada font respecter le NEC ou le CEC et/ou d’autres
codes d’installation locaux. Un fil de cuivre massif de 8,37 mm2 (8 AWG) est
requis, conformément aux normes NEC et CEC (l’exigence CEC est de 6 AWG), la
liaison devant être réalisée à l’aide d’un conducteur en cuivre massif, n° 8
AWG ou plus. Au Canada, il faut utiliser du AWG nº 6 ou plus gros. Le
contrôleur des produits chimiques TruDose ne comporte aucune pièce métallique
exposée nécessitant une liaison équipotentielle, ni aucune pièce métallique en
contact avec le système de circulation d’eau, et ne nécessite donc pas de
connexions de liaison équipotentielle.
Le National Electrical Code® (NEC®) requiert la mise à la terre de la piscine.
Lorsqu’aucun(e) équipement, structure ou pièce de la piscine mis(e) à la terre
n’est en connexion directe avec l’eau de la piscine, l’eau de la piscine devra
être en contact direct avec une surface conductrice approuvée résistante à la
corrosion qui n’expose pas moins de 5800 mm² (9 po²) de la surface de l’eau de
la piscine en tout temps. La surface conductrice devra être située à un
endroit où celle-ci n’est pas exposée à des dommages physiques ou à des
délogements au cours des activités courantes en piscine, et devra être mise à
la terre conformément aux exigences en matière de mise à la terre du NEC
Article 680. Se reporter aux codes appliqués localement pour toute exigence
supplémentaire en matière de mise à la terre.
FRANÇAIS
PAGE 41
PAGE 42
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
Section 4. Démarrage et arrêt
4.1 Chimie de l’eau
Commencer avec l’eau équilibrée de la piscine et du spa.
1. Utiliser une trousse de test chimique pour piscine avec des réactifs de
test frais pour mesurer le pH, l’alcalinité et la dureté calcique de l’eau de
la piscine. Chaque piscine est unique et un professionnel du service de
piscine peut vous aider à déterminer la chimie optimale pour votre piscine.
Les valeurs ci-dessous sont les valeurs chimiques recommandées pour l’eau de
piscine selon la norme ANSI/ APSP/ICC-11 pour la qualité de l’eau dans les
piscines et spas publics.
Niveau sans chlore : PISCINE – Minimum 1 ppm, maximum 4 ppm. SPA – Minimum 2
ppm, maximum 5 ppm.
pH : 7,2 à 7,8
Alcalinité totale : 60 à 180 ppm
Dureté calcique : PISCINE 150 – 1 000 ppm, SPA 100 – 800 ppm.
Total des solides dissous (TSD) : Maximum 1 500 ppm (Chlore de sodium non
inclus)
Indice de saturation Langelier (LSI) : -0,3 à +0,5
IMPORTANT : Les désinfectants pour piscines et/ou spas enregistrés par l’EPA
doivent être utilisés conformément aux exigences d’utilisation et/ou de
fonctionnement de l’étiquette du fabricant du produit acceptée par l’EPA.
4.2 Démarrage
1. Insérer le contrôleur dans la prise d’alimentation. Pour les installations
à l’extérieur, s’assurer d’utiliser un couvercle de sortie étanche.
2. Allumer la pompe de filtration et vérifier le débit d’eau à travers la
cellule d’écoulement en ouvrant la vanne de l’orifice d’échantillonnage (au
centre) et en observant un flux d’eau constant. La vanne du côté droit peut
devoir être partiellement fermée pour produire un flux constant.
REMARQUE : L’eau doit passer sur les capteurs de pH et de redox pendant au
moins 10 minutes pour permettre des lectures précises et stables des niveaux
de pH et de redox de la piscine.
3. Vérifier les fuites et réparer si nécessaire. 4. Ajuster et équilibrer
manuellement l’eau de la piscine à
des plages acceptables à l’aide d’une trousse de test.
REMARQUE : Utiliser une trousse de test basée sur DPD pour vérifier le niveau
de chlore.
5. Vérifier que la DEL de débit verte est allumée. Les sorties de dose pH et
ORP sont désactivées s’il n’y a pas de débit d’eau.
6. Appuyer momentanément sur le bouton-poussoir Mode pour placer le
contrôleur en mode de réglage du pH. La DEL de réglage du pH verte s’allumera.
Sélectionner le niveau de pH et la durée de dosage souhaités (secondes).
7. Tout en restant en mode de réglage du pH, appuyer sur le bouton-poussoir
pH Cal pour calibrer la lecture à la valeur observée lors du test manuel de
l’eau.
REMARQUE : Toujours calibrer en utilisant l’eau du port d’échantillon de la
cellule de débit.
8. Appuyer momentanément sur le bouton-poussoir Mode pour placer le
contrôleur en mode de réglage ORP. La DEL de réglage du ORP jaune s’allumera.
Sélectionner le niveau de consigne d’ORP souhaité.
REMARQUE : Si le niveau de pH dans la piscine est au niveau de consigne
souhaité et que le niveau de chlore/brome est au niveau de PPM souhaité dans
la piscine, le niveau de consigne de redox doit être le même que la lecture
actuelle de redox en mode automatique.
4.3 Arrêt
REMARQUE Chaque fois que le bouton-poussoir Mode est momentanément enfoncé, le
mode passe du réglage automatique au réglage du pH au réglage du redox, puis
revient au mode automatique.
1. Appuyer momentanément sur le bouton-poussoir Mode pour placer le
contrôleur en mode de réglage du pH. La DEL de réglage du pH verte s’allumera
et les affichages numériques du pH et de l’ORP afficheront des tirets.
2. Appuyer et maintenir enfoncé le bouton-poussoir Mode pendant 2 secondes
jusqu’à ce que les deux affichages pH et ORP indiquent OFF.
3. Le contrôleur s’éteindra et les affichages numériques et les DEL de
fonction s’éteindront. La DEL de débit verte s’allumera si de l’eau s’écoule à
travers la cellule de débit.
REMARQUE Le contrôleur est toujours sous tension à moins que l’alimentation ne
soit débranchée.
4.4 Modes et réglages
4.4.1 Auto Il s’agit du mode de fonctionnement normal. Le contrôleur permet un
fonctionnement et une surveillance complets des niveaux de pH et d’ORP
(désinfectant). Aucun bouton de fonction n’est opérationnel dans ce mode.
· La DEL de fonction rouge à côté d’auto est allumée.
· L’affichage numérique alterne l’affichage entre les lectures de pH et d’ORP.
4.4.2 Réglage du pH
REMARQUE Dans ce mode, la DEL de réglage du pH verte s’allumera, les
affichages numériques pH et ORP afficheront des tirets et toutes les fonctions
automatiques seront désactivées. Lorsqu’un bouton-poussoir de fonction est
enfoncé, l’affichage numérique indique la fonction.
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 43
a. Régler le niveau
1. Défaut : 7,4 pH 2. Plage à choisir : pH 7,0 à 8,0 (avec 0,1 incréments)
b. Minuterie de dose
1. Défaut : Dose temporisée de 30 secondes pompe pH sous tension et 5 minutes
pompe d’alimentation pH en retard (temps de mélange). En mode cycle de dose
minuté, la DEL de dose clignotera pendant le dosage et s’allumera de façon
continue pendant la partie de retard du cycle minuté.
2. Plage à choisir : OFF et temporisé (10-900 secondes ON et 5 minutes OFF).
3. S’assurer de vérifier séparément l’alcalinité totale (TA) de votre piscine
régulièrement. L’ajout d’acide à l’eau de votre piscine réduira l’alcalinité
totale.
4. Pour éviter les problèmes de suralimentation, il est recommandé de
démarrer l’unité avec les paramètres par défaut (30 secondes). Le temps de
dosage peut être augmenté si l’appareil n’est pas en mesure de maintenir la
valeur du pH à la valeur souhaitée.
c. Minuterie suralimentation
La minuterie de suralimentation désactive le dosage si le point de consigne du
pH n’est pas atteint dans un certain laps de temps. Il s’agit d’une fonction
de sécurité pour éviter le surdosage ou pour détecter si le réservoir d’acide
est vide. Les paramètres de la minuterie sont :
1. Préréglage : 60 cycles chronométrés. La minuterie de suralimentation ne se
réinitialise pas automatiquement. Elle doit être réinitialisée en éteignant
puis en rallumant le contrôleur ou en faisant basculer le mode hors auto et en
retournant à auto.
2. La minuterie de suralimentation est verrouillée avec la sélection de la
minuterie de dose.
Lorsque la limite de cycle préréglée est atteinte, la DEL d’alerte pH clignote
et « Er1» s’affiche sur l’écran ACL. La pompe doseuse pH est arrêtée pour
éviter un excès d’acide dans la piscine.
d. Alerte élevée – Défaut : 8,1 pH
1. Affichage : DEL d’alerte pH activée e. Alerte basse – Défaut : 6,9 pH
· Affichage : DEL d’alerte pH activée
f. Cal pH
· Permet un réglage de +/- 0,5 pH du relevé actuel.
4.4.3 Réglage ORP
REMARQUE : Dans ce mode, la DEL de réglage ORP jaune s’allumera, les
affichages numériques pH et ORP afficheront des tirets et toutes les fonctions
automatiques seront désactivées. Lorsqu’un bouton-poussoir de fonction est
enfoncé, l’affichage numérique indique la fonction.
Besoin de production de chlore (ORP plus bas que point de consigne)
Clignotant
Production de chlore éteinte (ORP plus élevé que point de consigne)
Désactivé(e)
Figure 14. Interfaces TruDose/APUREM
Besoin de production de chlore (ORP plus bas que point de consigne)
Clignotant
Production de chlore éteinte (ORP plus élevé que point de consigne)
Désactivé(e)
EXTERNAL CONTROL
Figure 15. Interfaces TruDose/TruClear XL
a. Régler le niveau 1. Défaut : 700 mV 2. Plage à choisir : 400 mV à 900 mV
(en incréments de
10 mV). b. Stratégie de dosage
· Par défaut : le contrôleur alimente en continu le relais 24 V.c.c.
contrôlant le chlorateur d’eau salée (non fourni), via le mode ORP jusqu’à ce
que le point de consigne ou la temporisation de suralimentation soit atteint.
PAGE 44
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
c. Minuterie suralimentation
La minuterie de suralimentation ORP est une fonction de sécurité qui désactive
le dosage si le point de consigne ORP n’est pas atteint dans un certain laps
de temps.
· Éviter le surdosage de produits chimiques en cas de mesure ORP erronée /
incohérente pendant une longue période.
· Détecter les problèmes de chlorateur d’eau salée.
· Défaut : La minuterie de suralimentation ORP s’allumera après 36 heures de
chloration sans atteindre le point de consigne ORP.
· Le temporisateur de suralimentation ORP peut être modifié à l’aide du bouton
poussoir « Dose time » en mode ORP. Défaut : 36 heures Plage à choisir : 12
heures à 96 heures de chloration (incrément de 12 heures).
Augmenter la minuterie de suralimentation si l’unité n’est pas en mesure de
maintenir le point de consigne ORP défini et déclenche régulièrement l’alerte
de suralimentation ORP.
· Affichage : La DEL ORP clignote en mode automatique et « Er2 » s’affiche sur
l’écran ACL.
· La minuterie de suralimentation ne se réinitialise pas automatiquement. Elle
doit être réinitialisée en éteignant puis en rallumant le contrôleur ou en
faisant basculer le mode hors auto et en retournant à auto.
d. Alerte élevée – 910 mV
1. Affichage : DEL d’alerte ORP activée e. Alerte basse – 390 mV
1. Affichage : DEL d’alerte ORP activée
4.4.4 Débit Le contrôleur de débit intégré est pré-câblé au contrôleur. Le
commutateur de débit doit être installé pour des raisons de sécurité afin
d’éviter le dosage de produits chimiques lorsqu’il n’y a pas de débit dans la
tuyauterie de circulation.
REMARQUE : Installer le petit filtre en ligne sur le tube d’admission allant à
la cellule de débit. Ne pas l’installer pourrait potentiellement entraîner un
dysfonctionnement de l’interrupteur de débit.
poussoir de mode. Les affichages pH et ORP afficheront « Ld ». Le contrôleur
reviendra aux réglages d’usine par défaut et sera placé en mode test.
Remettre le contrôleur en fonctionnement complet en éteignant le contrôleur
avec le bouton-poussoir de mode. Rallumer le contrôleur en appuyant sur le
bouton poussoir de mode.
REMARQUE : Le défaut d’exécuter cette action laissera le contrôleur en mode
test.
4.4.5 Réglages d’usine par défaut
Pour remettre le contrôleur aux réglages d’usine, placer le contrôleur en mode
veille. Éteindre le contrôleur en maintenant enfoncé le bouton-poussoir de
mode en mode veille. Appuyer et maintenir enfoncés les boutons-poussoirs de
réglage du niveau et de pH Cal, puis appuyer sur le bouton-
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 45
Section 5. Entretien
5.1 Hivernage (arrêts prolongés ou climats plus froids).
1. Éteindre le contrôleur et couper l’alimentation principale du contrôleur.
2. Desserrer les raccords de compression et retirer les capteur pH et rH de
la cellule de débit. Remplir les conteneurs de protection fournis (retirés
lors de l’installation) avec de l’eau de piscine puis les réinstaller sur
chaque capteur et les ranger dans un endroit chaud et sécurisé.
3. Vider l’eau de la cellule de débit.
5.3 Vérification du capteur pH
1. Le capteur de pH doit être vérifié tous les 6 mois ou après tout incident
lorsque le niveau de pH sort des limites.
2. Tout en restant attaché au contrôleur, placer le capteur dans un verre
d’eau du robinet propre. Se reporter à la Figure 16.
3. Ajouter une petite quantité d’acide ou de vinaigre à l’eau et faire une
lecture. Il doit afficher un nombre faible.
4. Placer le capteur dans une solution dont le pH est supérieur à 7,5 et
vérifier que la lecture augmente
5. Si le capteur n’affiche pas la lecture indiquée, il doit être remplacé.
5.2 Nettoyage des pointes du capteur
REMARQUE : Il est important de garder les pointes des capteurs propres pour
garantir des lectures précises.
Les pointes des capteurs doivent être nettoyées tous les 6 mois pour les
piscines résidentiels. Déterminer la fréquence nécessaire en comparant les
lectures avant et après le nettoyage. Des lectures identiques signifient que
le temps de nettoyage peut être prolongé.
1. Couper l’alimentation du contrôleur. 2. Fermer les vannes droite et gauche
au bas de la cellule
de débit. 3. Desserrer l’écrou du raccord à compression et retirer
délicatement le capteur de la cellule de débit. 4. Rincer le capteur avec de
l’eau propre. 5. Délicatement, brosser les joints, l’ampoule et la bande
métallique à l’aide d’une brosse à dents pendant une minute.
REMARQUE : NE PAS toucher la pointe du capteur.
6. Tremper les capteurs pendant 2 minutes dans une solution diluée d’acide
chlorhydrique (10 gouttes pour 2 onces liquides d’eau du robinet).
7. Rincer le capteur dans de l’eau du robinet propre pendant une minute.
8. Réinsérer doucement le capteur dans le raccord à compression et serrer
l’écrou à la main.
9. Brancher le cordon d’alimentation du contrôleur. Ouvrir les vannes de la
cellule à écoulement et attendre quelques minutes que le système se stabilise,
s’assurer qu’il n’y a pas de fuites et obtenir une lecture précise. Ajuster le
niveau de réglage si nécessaire.
10. Si le capteur n’affiche pas les lectures attendues, il doit être
remplacé.
5.4 Vérification du capteur ORP
1. Le capteur ORP doit être vérifié tous les 6 mois ou après un événement de
désinfection excessive.
2. Nettoyer la pointe du capteur comme indiqué dans la section précédente.
3. Mettre les capteurs dans un verre d’eau du robinet. La lecture doit
indiquer entre 200 mV et 400 mV. Se reporter à la Figure 16.
4. Après avoir ajouté une pincée de dichlore ou de trichlore dans l’eau, la
lecture devrait indiquer entre 750 mV et 800 mV.
REMARQUE : Si un désinfectant avec un pH élevé est utilisé au lieu du dichlore
ou trichlore, la lecture doit indiquer entre 650 mV et 750 mV.
5. Si le capteur n’affiche pas les lectures indiquées, il doit être remplacé.
pH 7.2-7.6 ORP 600-800 mV
Figure 16. Vérifier les capteurs.
PAGE 46
FRANÇAIS
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
Section 6. Procédure de remplacement de tuyauterie de pompe à produits
chimiques
AVERTISSEMENT
Débrancher l’alimentation du TruDose avant l’entretien en débranchant
l’alimentation électrique au niveau de la prise.
AVERTISSEMENT
Pour réduire le risque d’exposition, lire ce qui suit : · Vérifier
régulièrement l’étanchéité du tube de la pompe.
Au premier signe de fuite, remplacer le tube de la pompe. · L’utilisation
d’équipements de protection individuelle
appropriés est obligatoire lorsque l’on travaille sur ou à proximité des
pompes de dosage. · Avant l’entretien, l’expédition ou le stockage, pomper de
généreuses quantités d’eau ou une solution tampon compatible pour rincer la
pompe. · Consulter la fiche MSDS pour des informations supplémentaires et des
précautions pour l’additif utilisé. · Le personnel doit être qualifié et formé
à la sécurité et à la manipulation appropriées de l’additif utilisé. ·
Inspecter fréquemment le tube pour détecter toute fuite, détérioration ou
usure. Programmer un changement d’entretien régulier du tube de la pompe pour
éviter d’endommager les pompes et/ou les déversements.
MISE EN GARDE
· Faire preuve de prudence extrême lors du remplacement du tube de la pompe.
Faire attention aux doigts et NE PAS les mettre près des rouleaux.
AVERTISSEMENT
Pour réduire le risque d’exposition à la pression dangereuse, lire ce qui suit
:
· Faire preuve de prudence et purger toute la pression du système résident
avant de tenter l’entretien ou l’installation.
· Faire preuve de prudence lors du débranchement de la tuyauterie de
refoulement de la pompe. La décharge peut être sous pression. La tuyauterie
peut contenir du fluide à doser.
ATTENTION
· La pompe doit être connectée de manière permanente à un circuit électrique
dédié. Aucun autre équipement, éclairage, appareil ou prise de courant ne peut
être connecté au circuit de pompe.
· NE PAS appliquer de graisse, d’huile ou de lubrifiants sur le tube ou le
boîtier de la pompe.
· Avant de remplacer le tube de pompe, inspecter l’ensemble de la tête de
pompe pour détecter des fissures ou des composants endommagés. S’assurer que
les rouleaux tournent librement.
· Rincer le liquide résiduel et nettoyer tout le liquide et les débris des
composants de la tête de pompe avant de remplacer le tube.
· NE PAS tirer excessivement sur le tube de la pompe. Éviter les plis ou les
dommages lors de l’installation du tube.
· Inspecter le tube d’aspiration/refoulement, le point d’injection (dans le
tuyau) et le raccord d’injection pour détecter tout blocage après une rupture
de tube. Effacer ou remplacer au besoin.
6.1 Préparation
1. Suivre toutes les consignes de sécurité avant le remplacement de
tuyauterie et porter un équipement de protection individuelle adéquat.
2. Avant de faire l’entretien, pomper de l’eau ou une solution tampon
compatible dans la pompe et la conduite d’aspiration et de décharge pour
éliminer le fluide et éviter le contact.
3. Désactiver la pompe. 4. Déconnecter les raccordements d’aspiration et de
décharge de la tête de la pompe.
6.2 Retirer la tuyauterie
REMARQUE : Toujours éteindre la pompe de dosage avant de commencer des travaux
d’entretien.
1. Arrêter la pompe. 2. Retirer les vis de blocage cruciformes sur le loquet.
Glisser la languette verticale à 180 degrés de gauche à droite pour
déverrouiller le loquet du couvercle. Se reporter à la Figure 17.
Figure 17. Déverrouiller le loquet du couvercle 3. Pour enlever le couvercle
glissant, pousser vers le haut
au bord levé. Se reporter à la Figure 18.
Figure 18. Enlever le couvercle glissant
Jandy® TruDoseTM Contrôleur des produits chimiques | Manuel d’installation et de fonctionnement
FRANÇAIS
PAGE 47
4. Dégager les raccords des fentes pour enlever le tube. Se reporter à la Figure 19.
2. Aligner le couvercle du boîtier du tube avec la rainure et glisser par- dessus le
References