Laserliner 081-265 Master Level Compact Plus Instructions

June 5, 2024
Laserliner

Laserliner 081-265 Master Level Compact Plus

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / application

This digital electronic spirit level features a 360° angle display and a reference function to transfer angles. Measured data transfer via Bluetooth® interface.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.

  • The measuring tools and accessories are not toys.
    Keep out of reach of children.

  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.

  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.

  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.

  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or
    be subject to hazards or interference.

  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & Co. KG hereby declares that the MasterLevel Compact Plus radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=malecopl 

Laserliner-081-265-Master-Level-Compact-Plus-fig1

  1. Hold function on/off acoustic signal generator on/off Calibration
  2. On/off button / READ: Transfer measured data via Bluetooth® interface
  3. Magnetic measuring edge
  4. Battery compartment (Rear)
  5. Change units of measure/angle reference value setting
  6. Units of measure
  7. Slope angle
  8. Hold function active

Inserting battery

Open the battery compartment and insert battery according to the symbols. Be sure to pay attention to polarity.

Switching on and measuring

Make sure that the reference function is deactivated before measuring (no REF in the display).

– Switch the DigiLevel Plus on using the on/off switch (3).
– The slope angle (8) is shown in the display. If slopes are measured overhead, the direction of display adjusts automatically.

Calibration

  1.  Place the measuring face (4) on an even surface with position mark. Switch on device (3).
    To access calibration mode simultaneously press buttons 1 and 3. -1- appears on the display.

  2.  Press the ON/OFF button (3) again.

    • 1- flashes. The display then changes to -2-.
  3.  Turn the spirit level by 180° and place it exactly on the marked surface. Now press the ON/OFF button (3). -2- flashes. Calibration is concluded when the measured value appears on the display.

Reference function to transfer angles

Laserliner-081-265-Master-Level-Compact-Plus-fig5

HOLD

Auto Off function
In order to preserve the battery, the measuring device switches off automatically if it is left idle for 5 minutes.

Error code
Alignment of the vertical axis is outside the tolerance range

Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

Data transfer

The device features a Bluetooth® function that enables wireless data transfer to mobile devices with a Bluetooth® interface (such as a smartphone or tablet). The system prerequisites for a Bluetooth® connection are specified at http://laserliner.com/info?an=ble
The device can set up a Bluetooth®
connection with Bluetooth 4.0 compatible devices.
The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, sources of interference as well as the transmit/receive properties of the terminal device.
Once it has been activated, Bluetooth®* remains switched on indefinitely as the radio system is designed with exceptionally low power consumption.
A mobile device can link up to the active measuring device via an app.

  • The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.

Application (app)

An app is required to use the Bluetooth®* function. You can download the app from the corresponding stores for the specific type of terminal device:

Laserliner-081-265-Master-Level-Compact-Plus-fig4 Make sure that the Bluetooth®* interface of the mobile device is activated.

After starting the app and activating the Bluetooth®* function, a connection can be set up between a mobile device and the measuring device. If the app detects several active measuring devices, select the matching device.
This measuring device can be connected automatically the next time it is switched on.

  • The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Danger – powerful magnetic fields

Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks). With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republic of Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at least 20 cm away from the magnet.

Technical data **** subject to technical change without notice. 18W11

Electronic measuring precision| ± 0,05° at 0° and 90°

± 0,1° at 1°…89°

Display accuracy| 2 decimal places
Operating conditions| 0…50°C, 85%rH, no condensation, max. altitude 2000 m
Storage conditions| -20…70°C, 85%rH, no condensation

Radio module operating data

| Bluetooth LE 4.x interface; frequency band: ISM band 2400–2483.5 MHz, 40 channels; transmission power: max. 10 mW; bandwidth: 2 MHz; Bit rate:

1 Mbit/s; modulation: GFSK/FHSS

Power supply| 2 x 1.5V (type AAA/LR03)
Dimensions (W x H x D)| 152 x 60 x 33 mm
Weight (incl. battery)| 290 g

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: http://laserliner.com/info?an=malecopl

SERVICE

Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932 638-333 info@laserliner.com 

Umarex GmbH & Co. KG Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333 www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals