Laserliner 1519007 Battery tester BatteryCheck Reading range Instruction Manual

June 5, 2024
Laserliner

Laserliner 1519007 Battery tester BatteryCheck Reading range

| Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference.
---|---

Function / Application

This battery tester is used to check all commonly used batteries (AA / AAA / C / D / 9V / 1.5V button cells). The battery charge level is shown on a clear 3-colour scale. Operates without a power supply

  1. Battery holder:
    Button cell (1.5V) / Micro AAA / Mignon AA / Baby C / Mono D
    1a Negative pole, battery holder
    1b Positive pole, battery holder

  2. Battery holder: 9V block
    2a Negative pole, battery holder
    2b Positive pole, battery holder

  3. 3-colour display scale green: good orange: weak red: replace

Safety information

  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The tester operates in the voltage range from 1.5V to 9V.
  • Make sure the inserted, correspondingly rated batteries only make contact at the marked contact surfaces.
  • Insert the batteries the right way round to ensure correct polarity; polarity reversal can adversely affect operation of the device.
  • The device must only be used in accordance with its intended purpose and within the scope of the specifications. Modifications or changes to the device are not permitted, this will otherwisinvalidate the approval and safety specifications.

Additional information on use

The scale divides the usability of batteries in mobile devices into „good“, „weak“ and „replace“.
The divisions are based on general average values for constant use and can vary in devices with abnormal current consumption.
Especially in devices with high, temporary current peaks and/or for inferior quality batteries, it may be necessary to change the battery earlier than indicated on the display.
Devices with efficient power management can generally still operate effectively even when the batteries are almost completely discharged.
In such cases try to correspondingly interpret the deflection of the pointer in relation to the operating time of your specific device/ batteries to ensure optimum utilisation of the batteries.

To check battery charge

Open battery holder and insert batteries corresponding to the polarity symbols or place 9V block batteries on the contacts 2a and 2b.
Be sure to pay attention to polarity.

3-colour display scale

Good (green): battery fully charged
Weak (orange): battery is weak and will soon need replacing
Replace (red): battery is flat and should be replaced

To check battery charge

Technical data

Measuring ranges 1,5V / 9,0V
Battery types 1,5V

AAA, SH16, MN2400, LR03, R03
AA, HP7, MN1500, UM3, LR6, R6
C, HP11, MN1400, SP11, LR14, R14, UM2
D, HP2, MN1399, SP2, R20, UM1, LR20
LR41, LR43, LR44
9,0V
6LR61, 6F22, 6LF22
PP3, MN1604, 6F22, 006P
Dimensions (W x H x D)| 67 x 110 x 32,5 mm
Weight| 51 g

Subject to technical changes without notice. 08.14

BatteryCheck

Guarantee, product care and disposal

for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com/info

SERVICE

Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
laserliner@umarex.de

Umarex GmbH & Co KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com

Laserliner-Logo.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals