hytronik HBIR28 2CH Reinforced Low-bay Wide User Manual
- June 5, 2024
- HYTRONIK
Table of Contents
- hytronik HBIR28 2CH Reinforced Low-bay Wide
- Product Description
- App Features
- Technical Specifications
- Mechanical Structure & Dimensions
- Wire Preparation
- Detection Pattern & Optional Accessories
- Wiring Diagram
- Dimming Interface Operation Notes
- Additional Information/ Documents
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
hytronik HBIR28 2CH Reinforced Low-bay Wide
Product Description
HBIR28/2CH is a Bluetooth PIR standalone motion sensor, On/Off control with two independent relay channel outputs. It has two relays built-in: one is voltage-free contact, which is NO (normally open contact) and NC (normally closed contact) 2-in-1, the other is normally closed relay output. It is ideal for typical indoor applications such as office, classroom, healthcare and other commercial areas. With Bluetooth wireless mesh networking, it makes communication between luminaires much easier without time-consuming hardwiring, which eventually saves costs for projects (especially for retrofit upgrade projects!). Meanwhile, simple device setup and commissioning can be done via app.
App Features
Technical Specifications
Sensor Data
Sensor Model| PIR detection
HBIR28/2CH| Installation Height : 6m Detection Range(Ø) :9m
HBIR28/2CH/R| Installation Height : 6m
Detection Range(Ø) :10m
HBIR28/2CH/W| Installation Height : 6m
Detection Range(Ø) :18m
HBIR28/2CH/H
| Installation height:15m (forklift)
12m (person) Detection range (Ø):24m
HBIR28/2CH/RH
| Installation height:20m (forklift)
12m (person) Detection range (Ø):40m
Detection angle| 360O
Input & Output Characteristics
Operating voltage| 220~240VAC 50/60Hz
Stand-by power| <1W
Load ratings
| Channel 1: 400VA
Channel 2: 24VDC@2A,250VAC@2A
Warming-up| 20s
Safety & EMC
EMC standard (EMC)| EN55015, EN61000, EN61547
Safety standard (LVD)| EN60669-1, EN60669-2-1 AS/NZS60669-1/-2-1
RED| EN300328, EN301489-1/-17
Certifcation| CB, CE , EMC, RED, RCM
Environment
Operation temperature | Ta: -20OC ~ +50OC |
---|---|
IP rating | IP20 |
For more details of defection range, please refer to detection pattern secfion
Mechanical Structure & Dimensions
- Ceiling (drill hole Ø 66~68mm)
- Carefully prise off the cable clamps.
- Make connections to the pluggable terminal blocks.
- Insert plug connectors and secure using the provided cable clamps, then clip terminal covers to the base.
- Fit detection blind (if required) and desired lens.
- Clip fascia to body.
- Bend back springs and insert into ceiling
Wire Preparation
Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.
Detection Pattern & Optional Accessories
Wiring Diagram
Original status (stand-by)
By connecting L and COM, the VFC {voltagetree contact) channel can also be
turned into a common Switch L output to achieve separate
control ot the two Switch L channels.
Dimming Interface Operation Notes
Switch-Dim
The provided Swifch-Dim interface allows for a simple dimming method using
commercially available non-latching (momentary) wall switches. Detailed Push
switch configurations can be sef on Koolmesh app
Switch Function | Action | Descriptions |
---|
Push switch
| Short press (<1 second)
- Short press has to be longer than 0.1s, or it will be invalid.
| – Turn on/off – Recall a scene
– Turn on only – Quit manual mode
– Turn off only – Do nothing
Double push
| – Turn on only – Quit manual mode
– Turn off only – Do nothing
– Recall a scene
Long press (≥1 second)
|
– Do nothing
Simulate sensor| /| – Upgrade a normal on/off motion sensor to a Bluetooth controlled motion sensor
Additional Information/ Documents
- To learn more about detailed product features/tuncvtions, please reter to www.hytronik.com/download >knowledge >lntroduction of App Scenes and Product Functions
- Regarding precautions tor Bluetooth product installation and operation, please kindly reter to www.hytronik.com/download >knowledge >Bluetooth Products – Precautions tor Product Installation and Operation
- Regarding precauftions for PlR Sensors installation and operafion, please kindly reter to www.hytronik.com/download >knowledge >PR Sensors – Precautions for Product Installation and Operation
- Data sheet is subject fo change without notice. Please always reter to the most recent release on www.hytronik.com/products/bluetooth technology >Bluetooth Sensors
- Regarding Hytronik standard guarantee policy, please reter to www.hytronik.com/download >knowledge >Hytronik Standard Guarantee Policy