HYTRONIK HBEM8200D-F Built-in DALI-to Bluetooth Converter-Translator Module Instruction Manual
- October 30, 2023
- HYTRONIK
Table of Contents
HYTRONIK HBEM8200D-F Built-in DALI-to Bluetooth Converter-Translator Module
Product Description
HBEM8200D/F is a DALI/Bluetooth convertor, which converts a standard DALI/DALI2 emergency driver output to Bluetooth output, so that user can view, edit and manage the emergency system though high-end Koolmesh platform. User can then enjoy all the powerful and convenient features in Koolmesh platform, such as scheduling a monthly self test or annually self test in the app, checking the DALI/DALI2 emergency drivers’ status, including automatic email notication upon detecting fault, automatic monthly/yearly (functional/duration test) emergency report generation etc. All the settings and parameters can be set in both Koolmesh app and Koolmesh IOT platform.
App Features
| Floorplan feature to simplify project planning
---|---
| Grouping luminaires via mesh network
| Scenes
| Push switch con‑guration
| Schedule to run scenes based on time and date
| Astro timer (sunrise and sunset)
| Device ‑rmware update over-the-air (OTA)
| Power-on status (memory against power loss)
| Ofine commissioning
| Different permission levels via authority management
| Network sharing via QR code or keycode
| Remote control via gateway support HBGW01
| Interoperability with Hytronik Bluetooth product portfolio
| Compatible with EnOcean BLE switches
| Continuous development in progress…
Hardware Features
| l00mA DALI broadcast output for up to 50 LED drivers
---|---
| Compact design
| 2 Push inputs for flexible manual control
| Short-circuit protection
| Overload protection
| 5-year warranty
Fully support EnOcean self-powered switch module PTM2 l 5B (HBES0 1 /W & HBES0 1 /B)
5.0 SIG mesh
|
Smartphone app for both iOS & Android platform
|
Koolmesh Pro app for iPad
|
Web opp/platform: www.iot.koolmesh.com
Note:
Point to Point Control: l pc HBEM8200D/F convertor for l pc 3rd party
DALI/DALl2 emergency driver.
Remote Control and Monitoring: with Bluetooth gateway HBGWOl, users can
remotely control and monitor emergency system via Koolmesh mobile/tablet opp &
web opp platform.
HBEM8200D/F & 3rd Party standard DALI/DALl2 emergency driver does not need to
connect to central DALI PSU.
HBEM8200D/F provides power supply to the 3rd party standard DALI/DALl2
emergency driver.
Technical Specifications
Bluetooth Transceiver
Operation frequency| 2.4 GHz 2.483 GHz
Transmission power| 4 dBm
Range (Typical indoor)| l0~30m
Protocol| ” 5.0 SIG Mesh
Environment
Operation temperature| Ta: -20°C – +50°C
Case temperature (Max.)| Tc : +75°C
Storage temperature| 20°c ~ 60°C
Relative humidity| 20 ~ 90%
IP rating| IP20
Insulation| Class II
Input & output Characteristics
Operating voltage| 220 240VAC 50 / 60 Hz
Load rating| 100mA, l 6VDC (max. 50 devices)
Safety & EMC
EN55015, EN6 l 547| EMC standard (EMC)
Safety standard (LVD)| EN62479, EN6 l 000
Radio Equipment (RED)| IEC/EN 61058, AS/NZS 61058
EN301489- l /-17, EN62479| EN300 328,
Semko, CB, CE, EMC, RED, RCM| Certification
Mechanical Structure & Dimensions
Wire Preparation
To make or release the wire from the termin al, use a screwd river to push down the button.
- 200 metres (total) max. for 1 mm’ CSA (Ta= 50°C)
- 300 metres (total) max. for 1.5mm’ CSA (Ta= 50°C)
Wiring Diagram
Normal Mode
It is the mode in which mains supply is available, with the battery charged or
charging. In this mooe, HBEM8200D/F is a standard Bluetooth dimmer with DALI
broadcasting function, also with ability to create scenes and controllable by
motion sensor, Push switch, schedules and opp.
Emergency Mode
It is the mode in which mains supply hos foiled and whilst the control gear is
pcwered by the battery until deep discharge point. In this mode,
HBEM8200D/F is unable to be controlled by motion sensor, Push switch,
schedules and opp. However, some emergency parameters con still be conjured
via the opp. such as time scheduled for self-test, duration for extended
emergency mode etc.
Rest Mode
It’s the mode in which the luminoires ore intentionally off whilst the control
gear is powered by the battery. To enter this mooe, the prerequisite is that
there is no mains supply. In this mode, the luminoires will be turned off
automatically and HBEM8200D/F is powered by the battery. If the luminoires ore
forced to turn on in this mode, HBEM8200D/F will then be adjusted to emergency
mode. When mains supply is recovered, HBEM8200D/F will return to normal mode.
Inhibit Mode
It is the mode in which HBEM8200D/F is powered from mains but prevented from
going into emergency mode in the event mains failure. Please enter this mode
only in special applications whereby emergency functions is not needed, such
as when electricians need to cut off power supply when doing examinations and
maintenance work of HBEM8200D/F.
Extended Emergency Mode
It is the mode in which the control gear continues to operate the luminoires
in the some way as in emergency mode for the programmed prolong time ofter the
restorations of the mains supply. When this mooe is enabled, HBEM8200D/F will
remain in emergency mode even when mains supply is recovered. In this mooe,
the user must set the time extended for emergency mode; when the time extended
elapses, HBEM8200D/F will return to normal mooe.
Self test (Monthly)
HBEM8200D/F carries out routine test on emergency lighting based on pre-
programmed time via the opp & web opp ploform or ofter receiving manual
commands from the opp & web opp platform. During the self test process, tests
for load connections (such as open circuit, short-circuit) and battery
connections (such as open circuit, short-circuit, polarity reversal etc.) will
be carried out.
All the DALI emergency drivers Self Test feedbacks. results and related Events
(Such as the open circuit and short circuit of the load connection, open
circuit and short circuit for battery connection) ore generated by the driver
itself. the HBEM8200D/F convertor will only retrieve the data from the
emergency driver and translate the DALI feedback into Bluetooth Mesh data
correctly and accurately and display to the end user interface (App and Web
opp Platform). It will not contain any Emergency Self Test circuit in the
products itself.
Self test (Annually)
The test is carried out mainly to check the battery level. The user must make
sure that the battery for DALI emergency driver is fully charged before
HBEM8200D/F carries out annual test. Also, the battery lifetime statistics
will be analysed and displayed on a chart basis.
Push switch function
Users con connect Push switch to HBEM8200D/F to achieve multiple functions
such as manually trigger monthly self test, annually self test, invalid and
back to normal mode. Those options con be selected in Koolmesh opp Push switch
settings.
Dimming Interface Operation Notes
Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using commercially available non-latching [momentary) wall switches. Detailed Push switch configurations con be set on Kool mesh opp.
Switch Function | Action | Descriptions |
---|---|---|
Push switch | Short press [< l second) |
- Short press has to be longer than 0. ls, or it will be invalid.
|
- Turn on/ off
- Turn on only
- Turn off only
- Recall a scene
- Quit manual mode Do nothing
Double push|
- Turn on only
- Turn off only
- Recall a scene
- Quit manual mode Do nothing
long press (::> l second)|
- Dimming
- Color tuning
- Do nothing
Sensor-link| /|
- Upgrade a normal on/off motion sensor to a Bluetooth controlled motion sensor
Emergency Self-Test Function| Short press [< l second)
- Short press hos to be longer than 0. ls, or it will be invalid.
|
- Start Self
- Stop Self test [Monthly) test
- Start Self
- Invalid test [Annually)
long press (::> l second)|
- Start Self test [Monthly)
- Stop Self test
- Start Self test [Annually) Invalid
Fire Alarm [VFC signal only)| Refer to lfaalmesh”App User Manual V2.|
- Able to connect the Fire Alarm system
- Once the fire alarm system is triggered, all the luminaries controlled by the Push Switch will enter the preset scene [normally it’s full on), after the fire alarm system gives the ending signal, all the luminaries controlled by this Push Switch will revert bock to normal status.
Additional Information / Documents
- To learn more about detailed product features/functions, please refer to www.hytronik.com/download->knowledge ->Introduction of App Scenes and Product Functions
- Regarding precautions for Bluetooth product installation and operation, please kindly refer to wwwhytronik.com/download ->knowledge ->Bluetooth Products – Precautions for Product Installation and Operation
- Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology->DALl-to Bluetooth Converter/Translator Module
- Regarding Hytronik standard guarantee policy, please refer to wwwhytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>