Features

  • 12-24V constant voltage power repeater.
  • 5 channel, 5A per channel.
  • To receive PWM signal control.
  • Power repeater in series or in parallel to expand output unlimitedly.
  • Apply to RGB+CCT constant voltage LED strip or module.

Technical Parameters

Input and Output

nput voltage| 12-24VDC
Input current| 25.5A
Input signal| PWM
Output voltage| 5 x (12-24)VDC
Output curren| 5CH,5A/CH
Output power| 5 x (60-120)W
Output type| Constant voltage
Environment
Operation temperature| Ta: -30 O C ~ +55 O C
Case temperature (Max.)| T c:+85O C
IP rating| IP20
Safety and EMC
EMC standard (EMC)| ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-17 V3.2.4
Safety standard(LVD)| EN 62368-1:2020+A11:2020
Certification| CE,EMC,LVD
Warranty and Protection
Warranty| 3 years
Protection| Reverse Polarit
Weight
Net weight| 0.243k g
Gross weight| 0.264k g

Mechanical Structures and Installations

Wiring Diagram

Wiring Diagram

Malfunctions analysis & troubleshooting

Malfunctions Causes Troubleshooting
No light
  1. No power.
  2. Wrong connection or insecure

|

  1. Check the power.
  2. Check the connection

Wrong color|

  1. Wrong connection of R/G/B/WW/CW wires

|

  1. Reconnect  /G/B/WW/CW wires

Uneven intensity between front and rear,with voltage drop|

  1. Output cable is too long.
  2. Wire diameter is too small.
  3. Overload beyond power supply capability.
  4. Overload beyond controller capability.

|

  1. Reduce cable or loop supply.
  2. Change wider wire.
  3. Replace higher power supply.
  4. Add power repeater

Safety & Warnings

  1. The product shall be installed and serviced by a qualified person.
  2. This product is non-waterproof. Please avoid the sun and rain.
  3. Good heat dissipation will prolong the working life of the controller,Please ensure good ventilation.
  4. Please check if the output voltage of any power supplies used comply with the working voltage of the product.
  5. Ensure all wire connections and polarities are correct and secure before applying power to avoid any damages to the LED lights.
  6. If a fault occurs please return the product to your supplier. Do not attempt to fix this product by yourself.