ARROW NA-15703-PCDC Pressure Injectable Three-Lumen CVC Instructions
- June 4, 2024
- Arrow
Table of Contents
ARROW NA-15703-PCDC Pressure Injectable Three-Lumen CVC
Contents
- Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 20 cm, Pressure Injectable
- Drape: 41″ x 55″ with 4″ fenestration
- Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight 1: Needle Holder
Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
- Safety Scalpel: 11
- Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer 1: Flow Rate Information Card with Injection Log
Needle
- Medication Label: 1% Lidocaine
- Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm)
- Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
- Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
- Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
- Pressure Transduction Probe
- Suture: 3-0 Silk with Curved Needle
- Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL
- Tubing±: 20″ (50 cm) Extension
Arrow Raulerson Spring-Wire Introduction Syringe
- 1A trademark of Becton, Dickinson, and Company.
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip 2A registered trademark of CareFusion or one of its subsidiaries. Syringe
- Syringe: 3 mL Luer-Lock
- Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
- 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
- 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution
Hi-Lite OrangeTM Tint
- second site Adjustable Hub: Fastener
- second site Adjustable Hub: Catheter Clamp
- SharpsAway Disposal Cup
- SharpsAway II Locking Disposal Cup
Rx only
Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65 WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov
Precaution
**Contains Phthalate
**
DEHP Warning
The results of certain animal experiments have shown phthalates to be
potentially toxic to reproduction. Proceeding from the present state of
scientific knowledge, risks for male premature infants cannot be excluded in
the case of long-term exposure or application. Medical products containing
phthalates should be used only temporarily with pregnant women, nursing
mothers, babies, and infants. Not made with natural rubber latex. Store
between 20 25°C (68 77°F). Sterilized using ethylene oxide unless
otherwise indicated in the contents list. Fluid path components are non-
pyrogenic. Arrow International provides the enclosed medication label(s) for
your convenience. Please ensure that these labels are applied to the correct
syringe and corresponding medication.
- Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height.
- Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing.
Read User Manual Online (PDF format)