ARROW CS-47702-E Teleflex Incorporated Vascular Acces Instructions

June 1, 2024
Arrow

ARROW-LOGO

ARROW CS-47702-E Teleflex Incorporated Vascular Acces

ARROW-CS-47702-E-Teleflex-Incorporated-Vascular-Access-
PRODUCT

Product Information

Specifications

  • Dimensions:

    • Width: 6-9/64 (15.6 cm)
    • Length: 8-21/32 (22 cm)
  • Model Numbers: PB-50014-100B, PBZ-50014-103A

  • Product of xxx Packaged in xxx

  • Model T50014100A6 Dimensions: 5 7/8 x 7 5/8

  • CAS #: 7440-48-4

  • EU Authorized Representative and Importer:

    • Teleflex Medical IDA Business and Technology Park Dublin Road,
      Athlone Co. Westmeath, Ireland
  • Manufacturer: Arrow International LLC, Subsidiary of Teleflex Incorporated

  • Lot Number Format: YYYY-MM-DD

  • Lumen: 7 2 Fr.

  • Catheter Length: 20cm

  • 032-inch dia. spring-wire guide

Product Usage Instructions

Priming Instructions

Priming volumes are approximate and are done without accessories.

To prime the catheter:

  1. Ensure all connections are secure.
  2. Fill the distal (14 Ga.) lumen with 0.57 mL of solution.
  3. Fill the proximal (18 Ga.) lumen with 0.40 mL of solution.

Flow Rate Instructions

The gravity flow rate for the catheter is approximately 4731 mL/hr for the distal lumen and 913 mL/hr for the proximal lumen.

Frequently Asked Questions (FAQ)

Q: What are the contraindications for using the Arrowg+ard Blue Plus antimicrobial catheter?

A: The catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/or sulfa drugs.

Content

  • Arrowg+ard Blue Plus®1 Two-Lumen Catheter: 7 Fr. (2.5 mm OD) x 20 cm Spring-Wire Guide,
  • Marked: 032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer with ECG Mark
  • Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
  • Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW

Pressure Transduction Probe

  • Arrow® Raulerson Spring-Wire Introduction Syringe: 5 mL
  • Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
  • Dust Cap: Non-Vented
  • SecondSite ™ Adjustable Hub: Fastener
  • SecondSite ™ Adjustable Hub: Catheter Clamp
  • Licensed under US Patent No. 7,329,412.
  • All components are CE 2797 unless otherwise noted.
  • Rx only Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU Not made with natural rubber latex. Store below 25°C (77°F).
  • Avoid excessive heat above 40°C (104°F). Fluid path components are non-pyrogenic.
  • Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs.

Specification

  • Priming volumes are approximate and are done without accessories.
  • Flow rate values are approximate and are determined using deionized water at 100 cm head height.

Features

EU Authorized Representative and Importer:

  • Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co. Westmeath, Ireland
  • Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
  • www.teleflex.com
  • LBL074623 R00 (2024-03)
  • (01) X
  • (17)YYMMDD
  • (11)YYMMDD
  • (10)LotNumber
  • 7. 2 lumen 20 catheter length .032 inch dia. spring-wire guide
  • Arrowg+ard Blue Plus® Two-Lumen CVC

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals