ARROW CS-47702-E Teleflex Incorporated Vascular Acces Instructions
- June 1, 2024
- Arrow
Table of Contents
ARROW CS-47702-E Teleflex Incorporated Vascular Acces
Product Information
Specifications
-
Dimensions:
- Width: 6-9/64 (15.6 cm)
- Length: 8-21/32 (22 cm)
-
Model Numbers: PB-50014-100B, PBZ-50014-103A
-
Product of xxx Packaged in xxx
-
Model T50014100A6 Dimensions: 5 7/8 x 7 5/8
-
CAS #: 7440-48-4
-
EU Authorized Representative and Importer:
- Teleflex Medical IDA Business and Technology Park Dublin Road,
Athlone Co. Westmeath, Ireland
- Teleflex Medical IDA Business and Technology Park Dublin Road,
-
Manufacturer: Arrow International LLC, Subsidiary of Teleflex Incorporated
-
Lot Number Format: YYYY-MM-DD
-
Lumen: 7 2 Fr.
-
Catheter Length: 20cm
-
032-inch dia. spring-wire guide
Product Usage Instructions
Priming Instructions
Priming volumes are approximate and are done without accessories.
To prime the catheter:
- Ensure all connections are secure.
- Fill the distal (14 Ga.) lumen with 0.57 mL of solution.
- Fill the proximal (18 Ga.) lumen with 0.40 mL of solution.
Flow Rate Instructions
The gravity flow rate for the catheter is approximately 4731 mL/hr for the distal lumen and 913 mL/hr for the proximal lumen.
Frequently Asked Questions (FAQ)
Q: What are the contraindications for using the Arrowg+ard Blue Plus antimicrobial catheter?
A: The catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/or sulfa drugs.
Content
- Arrowg+ard Blue Plus®1 Two-Lumen Catheter: 7 Fr. (2.5 mm OD) x 20 cm Spring-Wire Guide,
- Marked: 032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer with ECG Mark
- Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW
Pressure Transduction Probe
- Arrow® Raulerson Spring-Wire Introduction Syringe: 5 mL
- Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
- Dust Cap: Non-Vented
- SecondSite ™ Adjustable Hub: Fastener
- SecondSite ™ Adjustable Hub: Catheter Clamp
- Licensed under US Patent No. 7,329,412.
- All components are CE 2797 unless otherwise noted.
- Rx only Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU Not made with natural rubber latex. Store below 25°C (77°F).
- Avoid excessive heat above 40°C (104°F). Fluid path components are non-pyrogenic.
- Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs.
Specification
- Priming volumes are approximate and are done without accessories.
- Flow rate values are approximate and are determined using deionized water at 100 cm head height.
Features
EU Authorized Representative and Importer:
- Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co. Westmeath, Ireland
- Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
- www.teleflex.com
- LBL074623 R00 (2024-03)
- (01) X
- (17)YYMMDD
- (11)YYMMDD
- (10)LotNumber
- 7. 2 lumen 20 catheter length .032 inch dia. spring-wire guide
- Arrowg+ard Blue Plus® Two-Lumen CVC
References