QXWZ Qianxun SI Survey RTK Receiver User Guide
- June 10, 2024
- QXWZ
Table of Contents
Qianxun SI RTK Quick Start
Product Introduction
The Quantum SI Survey RTK product suite consists of a Quantum SI Survey RTK
Receiver and related accessories.
Note: This instruction is applicable to Q300 and Q600 products.
Indicator Description:
Indicator
Light| Satellite Status| Blue light flashes when searching for stars, always
on after finishing positioning
---|---|---
Power Status| Power light blinks when the power is <10%
Data Status| Green light blinks 1s for differential data in dynamic RTK mode
Static mode blinks at sampling frequency interval
Key Description:
Key| Startup & Shutdown| Press and hold for 3s to turn on, long press for 3s
to turn off
---|---|---
Inquiry| Click the key to check the battery status
Mode Switch| Double-click the button to switch modes and click to confirm
Turn on the device
It is suggested to charge the device for the first time before using it.
Turn on the RTK host and controller → Press the “APP” button in the controller
to start the measurement software. The first time you use it, a privacy
agreement will pop up, accept it and use it.
Connecting Instruments
Click the device icon button in the upper right corner of the app to enter
the device connection interface. In the device connection interface, you can
choose to connect the device after using Wi-Fi search, as in Figure 1.
Note: Quantum SI survey RTK products start with “QX” by default, such as QX21000034
Activation
Host Registration
When you use the device for the first time, you need to use the registration
code to open the authorization to use the device. Please apply for the
registration code from the distributor who purchased the device.
Registration method: App upper right corner device icon → click [Device] in
the device information after the [Regis] button can be entered, prompt
Service Activation
If you have purchased a star-based service, you need to use the authorization
code to open it in order to achieve high-precision positioning operation
without network on a single device.
In the device information, you can click the [Regis] button after [Xyster] to
activate the star-based service, please consult the manufacturer’s technical
staff for service coverage.
Star-based service needs to update the key file once every six months, and you
can select the locally imported key file by [Select file].
New Project
When you enter the App, Qianxun SI has automatically created a project for
you.
The default project name is controller system time, the coordinate system is
WGS84, the projection is horizontal axis Makaton
If necessary, you can go to the left menu bar to create a new project or
modify the project information and the required coordinate system parameters,
as in Figure-2.
Figure-2
Data Import
In the point library, you can select the required data format and file to import data, as shown in Figure 3-6.
Work Mode Configuration
The first time you turn on the machine, it will automatically enable “Radio”,
you can directly carry out survey operations.
If there is no network on site or you have other needs, you can configure as
follows: Enter the device configuration interface through the left menu bar →
[Device Config] You can configure rover station, base station and static
station as required.
Create Rover Station Mode
Click the [Create] button, [Type] select [Rover], and choose the data chain
mode.
Radio: Some models have radio function, at this time you need another RTK to
be the Base station and broadcast differential data to the mobile station via
radio for measurement operation.
This mode is suitable for all outdoor work scenarios. Star-based: Some models
are equipped with star-based function. Star-based service does not depend on
network and does not need to set up a reference station, and can achieve
centimeter-level positioning by a single machine. The satellite-based service
needs to be opened according to the area, and high-precision operation can be
realized within the coverage of the satellite-based, please consult customer
service or authorized distributors for details.
Create Base Station Mode
Some models have base station function.
Click [Create] button, [Type] select [Base], configure radio related
parameters and click OK to finish the configuration. If there is a known
point, you can select [Known Point] mode, enter the ground point coordinates
and antenna slope height to start, as in Figure-8.
Create Static Station Mode
Static station mode is used for control network deployment and control point
encryption.
Click the [Create] button, select [Static] for [Type], and configure the
relevant parameters to complete the configuration. The default sample interval
is 10s and the default file format is RINEX3.02, as shown in Figure 9.
Survey
Menu bar on the left → [Survey], the main interface switches to point
measurement mode.
In the point measurement mode, you can select the first configuration button
in the right toolbar of the interface to configure the required measurement
parameters, as shown in Figure-10.
In the main interface, you can switch the type of measurement points ( Control
Point, Continuous Point, Rapid Point, Topographic Point, Eccentric Point),
enter the required number of observation points and other parameters, and then
click [Start survey] to collect the required type of points, as shown in
Figure-11.
[Parameter Calculation]
Point Correction
The first time you go to a survey area, you need to do point correction if you
want the measured point to match the known point coordinates. If you are using
Quantum SI network operation mode and your project coordinates match the
CGCS2000 coordinates broadcasted by Quantum SI, you can skip this step.
The left menu bar → [CRS] → [Site Caleb], you can enter the point correction
parameter calculation interface, as in Figure-12.
Select the plane coordinates of known points in N pairs of survey area and the
latitude and longitude coordinates under the ellipsoid corresponding to known
points, click [Calculate] to solve the plane correction and elevation fitting
parameters, and click [Apply] to apply the calculation results to the current
project coordinate system parameters and update all the measurement results,
as in Figure-13.
Station Shift
Site panning is required when a base station is moved or a reboot of a base
station started at an unknown point. If you are using Quantum SI Finds
service, you can skip this step, and you can directly turn on the power to
measure every day.
Menu bar on the left → [CRS] → [Station Shift], you can enter the site shift
selection interface.
Select the coordinates of known points in the measurement area and the
coordinates of latitude and longitude of the corresponding measurement points
to find out the translation amount, and click [OK] to apply the current
translation parameters to the corresponding base station of the currently
selected measurement point and update all the mobile stations measured under
the base station synchronously, as in Figure 14.
Data Export
The left menu bar → [Data] → [Export] to export the current measurement
results.
In the point library, select the desired point location, export file type, and
file format to export.
The exported data is stored in the Survey ate/RTK/project name/report
directory by default, and you can choose the export directory by yourself, as
in Figure-15.
Host Web
When you work separately from your teammates and need to change the base station configuration without PAD, you can use the “RTK Web” application in PAD system or cell phone webpage to enter the 1.1.1.1 host webpage interface to configure the equipment. Some models of cell phones need to turn off the 4G network and use WiFi to connect to the receiver, as shown in Figure-16.
Update
The RTK product suite is available for free lifetime firmware/software
upgrades to support new features and fix bugs. upgrades include RTK host
firmware, PAD system, and App software. Upgrade method.
You can contact our technical support staff to obtain the latest version of
the installation package, using USB offline upgrade. When upgrading, connect
the RTK host computer through the standard Type-C cable, put the upgrade
installation package into the RTK memory, APP upgrade package into the PAD
memory, restart the receiver / click the APP installation package in the PAD
to upgrade.
Caution
Charging: The battery holder charge is used in an environment of 0~40°C. It is
recommended to be used in a well-ventilated, non-direct sunlight environment.
Maintenance: The lithium battery should be charged with 50%~80% of power for a
long time without use, and removed from the instrument and stored in a dry and
cool environment, and charged once every three months to avoid irreversible
capacity loss.
Technical Support
If you have any technical questions, you can send an email to overseas@wz-
inc.com for technical support.
Quantum Spatial Intelligence(Zhejiang) Inc.
Registered address: No.1,Building12,Area C, Daqing Geographic Info Town,
Ouyang Street, Daqing County, Huzhou City, Zhejiang Province, China
Certificate of Conformity
The product is inspected and qualified and allowed to leave the factory.
Caution:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
RF Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment .This equipment should be installed and operated with
minimum distance 20cm between the radiator& your body.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>