RAB LIGHTING SBR10 CCT-Adjustable Emergency Tube Owner’s Manual
- June 5, 2024
- RAB Lighting
Table of Contents
RAB LIGHTING SBR10 CCT-Adjustable Emergency Tube
Product Information
Specifications:
- Catalog Number: SBR10
- Length: 4 ft
- Lumens: 5000K @ 1,800 lm, 5000K @ 124 lm/W
- Dim Type: Hardwired
- Input Voltage: 120-277V
- Color Temperature: 3500K/4000K/5000K
- CRI: 80
- L70 Lifespan: 50,000 hrs
- Base Type: Hardwired S-ZGJKLK
- DLC ID: 1
Product Usage Instructions
Installation:
The emergency tube is designed for quick and simple installation as an
emergency solution for T8 linear fixtures. Follow these steps:
- Turn off the power to the fixture.
- Remove existing sockets from the fixture.
- Wire the emergency tube directly to the mains power.
- Bypass the ballast as the driver is integrated into the lamp body.
- Select the desired color temperature using the provided options.
Usage:
The emergency tube provides backup battery-powered emergency illumination for
a minimum of 90 minutes up to 200 minutes. The tube is hardwired 24/7 to mains
power, ensuring continuous
operation in case of power outages.
FAQ:
-
Q: Is the emergency tube dimmable?
A: Yes, the emergency tube is dimmable down to 15-20% on compatible TRIAC/ELV dimming systems. -
Q: What is the warranty period for the product?
A: RAB warrants the LED products will be free from defects for a period of five (5) years from the date of delivery to the end user.
KEY FEATURES
- Designed to install quickly and simply as an emergency solution for T8 linear fixtures
- True UL 924-certified LED retrofit tube that is hardwired 24/7 to mains power
- Bypass the ballast: driver integrated directly into the lamp body
- 3 selectable color temperatures
- The backup battery provides 400 lumens of emergency illumination for a minimum of 90 minutes up to 200 minutes
- Easy to install, simply remove existing sockets from fixture and wire tube directly
Meets UL924 requirements
PERFORMANCE
Catalog Number| Length| Wattage Equivalency| Input
Wattage| Lumens| Efficacy| Dim Type| Input
Voltage| Beam Angle| Colour Temperature| CRI|
L70 Lifespan| Base Type| DLC ID
---|---|---|---|---|---|---|---|---|---|---|---|---|---
SBR10| 4 ft| 32W Fluorescent| 14.5W| ****
3500K @ 1,750 lm;
4000K @ 1,800 lm;
5000K @ 1,800 lm
| ****
3500K @ 121 lm/W;
4000K @ 124 lm/W;
5000K @ 124 lm/W
| TRIAC/ELV| 120-277V| 140°| 3500K/4000K/5000K| 80 CRI| 50,000 hrs| Hardwired| S-ZGJKLK
TECHNICAL SPECIFICATIONS
CONSTRUCTION
-
Product Type
Emergency Linear Tube -
Length
4 ft -
Shape
T10 -
Endcap Material
Polycarbonate -
Enclosure Material
Aluminum + Polycarbonate -
Finish
White
INSTALLATION
-
Installation Method
UL Type B, Ballast Bypass -
Base Type
Hardwired
ELECTRICAL
-
Dimmable
Yes, dimmable down to 15-20% on compatible TRIAC/ELV dimming systems. See Dimmer Compatibility List. -
Input Voltage
120-277V -
Operating Frequency
50/60 Hz -
Operating Temperature
32°F to 104°F (0° to 40°C) -
THD
0.2 -
Power Factor
0.9 -
Flicker
0.5 -
Emergency Operation
90 minutes @ 0° ambient temperature; 200-minutes @ 77° (25°) -
Emergency Lumens
400 lm (3.5W) -
Battery Recharge Time
24 hours @ 0° ambient temperature
LED CHARACTERISTICS
-
Beam Angle
140° -
Color Temperature
3500K/4000K/5000K -
Color Accuracy (CRI)
80 CRI -
R9 Value
High color performance with R9 greater than 0 -
Color Consistency
7-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color -
Color Stability
LED color temperature is warrantied to shift no more than 200K in color temperature over a 5-year period -
Color Uniformity
RAB’s range of Correlated Color Temperature follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017.
COMPLIANCE
-
Listings
UL Recognized, UL Classified -
Environment
Suitable for use indoors in dry and damp environments. -
Fixture Rating
Suitable for use in enclosed fixtures -
DLC Listed
This product is on the Design Lights Consortium (DLC) Qualified Products List and is eligible for rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements. -
California Title 20 Compliant
No -
California Title 24 JA8 Compliant
No -
California Energy Commission (CEC) Status
Lawful for Sales in California -
NSF Listed
Meets NSF/ANSI standards for use in Food Zone (non-contact), Splash, and Non- Food Zones. Tube guard required in open fixtures. -
RoHS
Mercury and UV free. RoHS-compliant components. -
FCC
Complies with Part 15 of the FCC Rules
OTHER
-
Warranty
RAB warrants that our LED products will be free from defects in materials and workmanship for five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish.
RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty. -
Note
All values are typical (tolerance +/- 10%)
DIMENSIONS
ORDERING
ORDERING INFO
Catalog Number | Model Number | UPC | Case Pack |
---|---|---|---|
SBR10 | BT01(SBR10) | 192552037051 | 10 |
ORDERING MATRIX
©2024 RAB Lighting Inc.