SmartGen SG485-2CAN Communication Interface Conversion Module User Manual
- June 3, 2024
- SmartGen
Table of Contents
Communication Interface Conversion Module
User Manual
All rights reserved. No part of this publication may be reproduced in any
material form (including photocopying or storing in any medium by electronic
means or other) without the written permission of the copyright holder.
Applications for the copyright holder’s written permission to reproduce any
part of this publication should be addressed to Smartgen Technology at the
address above.
Any reference to trademarked product names used within this publication is
owned by their respective companies. SmartGen Technology reserves the right to
change the contents of this document without prior notice.
Table 1 Software Version
Date | Version | Note |
---|---|---|
2021-08-18 | 1.0 | Original release. |
2021-11-06 | 1.1 | Modify some descriptions. |
2021-01-24 | 1.2 | Modify the error in Fig.2. |
OVERVIEW
SG485-2CAN is a communication interface conversion module, which has 4 interfaces, namely RS485 host interface, RS485 slave interface and two CANBUS interfaces. It is used to convert 1# RS485 interface to 2# CANBUS interfaces and 1# RS485 interface by DIP switch to set address, providing convenience for customers to monitor and collect data.
PERFORMANCE AND CHARACTERISTICS
Its main characteristics are as follows:
─ With 32-bit ARM SCM, high hardware integration, and improved reliability;
─ 35mm guide rail installation method;
─ Modular design and pluggable connection terminals; compact structure with
easy mounting.
SPECIFICATION
Table 2 Performance Parameters
Items | Contents |
---|---|
Working Voltage | DC8V~DC35V |
**** RS485 Interface | Baud rate: 9600bps Stop bit: 2-bit Parity bit: None |
CANBUS Interface | 250kbps |
Case Dimension | 107.6mmx93.0mmx60.7mm (LxWxH) |
Working Temperature | (-40~+70)°C |
Working Humidity | (20~93)%RH |
Storage Temperature | (-40~+80)°C |
Protection Level | IP20 |
Weight | 0.2kg |
WIRING
Fig.1 Mask Diagram
Table 3 Indicators Description
No. | Indicator | Description |
---|---|---|
1. | POWER | Power indicator, always on when powered on. |
2. | TX | RS485/CANBUS interface TX indicator, it flashes 100ms when sending |
data.
3.| RX| RS485/CANBUS interface RX indicator, it flashes 100ms when receiving
data.
Table 4 Wiring Terminals Description
No. | Function | Cable Size | Remark |
---|---|---|---|
1. | B- | 1.0mm2 | DC power negative. |
2. | B+ | 1.0mm2 | DC power positive. |
3. | **** RS485(1) | B(-) | **** 0.5mm2 |
controller, TR can be short connected with A(+), which is equivalent to
connecting 120Ω matching resistance between A(+) and B(-).
4.| A(+)
5.| TR
6.| RS485(2)| B(-)| 0.5mm2| RS485 slave interface communicates
with PC monitoring interface, TR can be short connected with A(+), which is
equivalent to connecting 120Ω
matching resistance between A(+) and B(-).
7.| A(+)
8.| TR
9.| CAN(1)| TR| 0.5mm2| CANBUS interface, TR can be short
connected with CANH, which is equivalent to connecting 120Ω matching
resistance between CANL and CANH.
10.| CANCEL
11.| CANH
12.| CAN(2)| TR| 0.5mm2| CANBUS interface, TR can be short
connected with CANH, which is equivalent to connecting 120Ω matching
resistance between CANL and CANH.
13.| CANAL
14.| CANH
/| USB| Software download and upgrade interface| ****
/
| **** /
Table 5 Communication Address Setting
Communication Address Setting
Address| RS485(2)| Reserved
DIP Switch No.| 1| 2| 3| 4| 5| 6| 7| 8
the corresponding relation between dial switch combination and
communication address| 000: 1| **** Keep the DIP address, it has no effect on
communication no matter how it is set.
001: 2
010: 3
011: 4
100: 5
101: 6
110: 7
111: 8
ELECTRICAL CONNECTION DIAGRAM
OVERALL DIMENSION AND INSTALLATION
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: +86-371-67988888/67981888/67992951
+86-371-67981000(overseas)
Fax: +86-371-67992952
Web: www.smartgen.com.cn/
www.smartgen.cn/
Email: sales@smartgen.cn