FLAT IRON 6329 Cellulite Reducing and Body Toning Device Instruction Manual
- June 5, 2024
- FLAT IRON
Table of Contents
FLAT IRON 6329 Cellulite Reducing and Body Toning Device
Pre-use Preparation
Please follow all instructions to insure you are safely and correctly using
this device.
The Fat iron comes with a THERMAL SENSOR designed to measure skin temperature
and stabilize the emitted heat energy.
To prevent overheating, a unique built-in heat stabilizer inside the device
measures the treated skin temperature during treatment. As a rise in the
treated skin temperature is detected (42°C-43°C), the stabilizer will
automatically stop emitting heat, until skin temperature lowers enough for the
stabilizer to resume heating.
Fatl Device is a non-invasive at home skin care device. It works with Red LED lights, micro-current (EMS) and radio frequency therapy (RF) Thermal technology.
Intended Use
The Fat Iron device is intended for cellulite. reduction, toning, and body skin stimulation. lbis device is indicated for over-the-counter cosmetic use. This device has been proven to improve muscle tone and firmness in the arms, abdomen, thighs and buttocks areas.
Features & Functions
1. The device has 3 programs:
RF and Red LED lights
EMS and Red LED lights
RF, EMS and Red LED lights
RF treatment:
Generating heat deep into the tissue and stimulate collagen production to
reduce the appearance of loose skin and cellulite. RF waves target and beat
the fat cells collected beneath the skin, causing them to break down. They are
then absorbed by the lymphatic system and naturally disposed of.
By providing heat energy up to 7mm below the skin’s surface, this frequency
helps the body to eliminate fat cells all together thus reducing cellulite
levels.
EMS (GENTLE MICRO-CURRENT TREATMENT)
The micro-current therapy works by mimicking and gently accelerating the
normal cell activity of skin which can slow down with age. Oxygen is more
easily absorbed, damaged tissue is repaired, and collagen production is
increased.
RED LIGHT (620-730nm Wavelength)
The red light penetrating 8-l0nun is suitable for any type of skin; it can
reach denna to stimulate fiber cells. Heating can improve blood circulation
and collagen albumen hyperplasia to reduce wrinkles and make skin more elastic
and smooth. The mild wave length is suitable for surrounding eyes and
forehead.
Safety Precautions
- Do not use body device on the head, face (including directly on the eyes and covering the mouth), neck (especially the carotid sinus), groin, upper back, chest area or crossing over the heart.
- You should stop using the device and should consult with your physician if you experience adverse reactions from the device.
- If you are under the care of physician, consult your physician before using this device.
- Do not use the device if you have a body-worn medical device such as an insulin pump or pace maker.
- Stimulation should not be applied over your neck as this could cause severe muscle spasms resulting in closure of your airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure.
- Application of the body device spherical electrodes across your chest(thorax area) may increase the risk of cardiac fibrillation or other rhythmic disturbances, which could be lethal.
- Do not use this device when there is a tendency to bleed following acute injury or breaks in bones.
- Do not apply stimulation over areas of skin that lack normal sensation.
- Apply stimulation only to clean and healthy skin.
- Stimulation should not be applied over or near cancerous wounds or open wounds such as rashes, swollen, infected, or inflamed areas or skin eruption, e.g. phlebitis, thromboplebitis, broken capillaries, varicose veins, etc.
- Do not apply stimulation while sleeping, bathing or showering.
- Do not apply stimulation while driving, operating machinery, or during any activity in which uncontrollable muscle twitching may put the user or the public at unnecessary risk of injury.
- If the device begins to overheat, turn the device off immediately.
- Keep this device out of the reach of children.
- Keep all electrical appliances (including the body device) away from water (including baths, showers and sinks).
- Never operate the device if it is not functioning properly, or not operating properly due to damage caused by dropping or accidental submersion in water.
General View of the Device
- Big key: to turn on/off and change modes
- Small key: to adjust intensity
- LED indicator
- RF indicator
- EMS indicator
- Intensity level indicator
- Metal massage probe
- Charging base
- DC connector
- Charging indicator
Operating Procedures
Getting Started!
-
Remove the Fat Iron device and other components from box.
-
Fully recharge the device with the AC/DC adaptor and cord.
-
Once charged, the device is now in standby mode and is ready to start.
-
Spread a thin layer of Primer Gel on the designated treatment area. Alternatively, spread a moderate amount of Primer Gel on the device’s TREATMENT SURFACE. The Primer Gel is designed to better conduct the energy into your skin, for optimal results.
-
Hold the Power & Mode button for 2-5 seconds to turn on the device. This will turn mode 1 on: RF and RED LED lights mode is working.
-
Repeat and press the Power & Mode button to select different modes:
Mode 1: RF & Red lights- Reduce the appearance of cellulite while treating the skin to reduce appearance of fine lines & wrinkles
Mode 2: EMS & Red light- Tone & Finn muscles while treating the skin to reduce appearance of fine lines & wrinkles
Mode 3: RF, EMS, & Red light- Combine all 3 options for maximum results. -
Press the Level button to adjust the intensity of RF and EMS. Total 5 levels.
-
Attach the TREATMENT SURFACE to the skin. Please note that the skin must be clean and dry before applying Primer Gel. Skin should be free of other moisturizers and lotions that can harm the device.
-
Atach the device to the designated skin area. You will feel a mild sensation of warmth. Move the device in gentle massage- like linear motions on the designated area (HIPS, BUTTOCKS, THIGHS, CALĘ, BACK, THORAX,
BELLY AND ARMS). Proceed slowly and carefully.
Note: -
The lights will only work when the device comes in contact with the skin. Device will automatically turn off if no contact is received for over 2 minutes.
-
The battery indicator light will turn red when battery is low. It turns back to white color when full char
-
The TREATMENT SURFACE cannot be in contact with the skin when in changing mode.
-
A “Beeping” sound will occur when the device switches to different modes.
-
The default intensity is set at the minimum level.
-
Press and hold the Power/Mode button for 2 seconds to turn off the body device after treatment.
Note:
For best result, you may choose to focus on a specific area of concern within the treatment area for the full 5 minute treatment cycle and then repeat over other areas as necessary. -
Select a preferred treatment area on either side of your body.
-
Cleanse the selected treatment area with an oil free cleanser. Any oil-based products on the skin can block the microcurrent.
-
Shave any excessive hair in the treatment area as it can create a tingling sensation.
-
Apply a mask like layer of Primer Gel. in within the selected treatment area.
* If skin become dry during the treatment apply more gel.
TREATMENT AREAS
There are seven (7) recommended treatment areas (see image below):
TREATMENT AREAS | SPECIFIC AREAS OF CONCERN |
---|---|
I | Right Upper Ann |
2 | Left Upper Ann |
3 | Abdomen/waist |
4 | lugbtTbigb |
5 | LeftThigh |
6 | Left Buttock |
7 | Right Buttock |
TREATMENT TECHNIQUES
GLIDES:
To glide, place the Fat Iron at the starting point of a treatment area, When
it beeps,slowly glide the device in an upward motion using medium pressure to
the endpoint until the beep sounds(5 seconds). See the illustration shown for
starting and ending points for each treatment area.
HOLDS
(Recommended for stubborn areas):
To hold, place -on the targeted area and hold in place for at least 2-3
beeps(l0-15 seconds). Do not glide. You may treat multiple stubborn areas
within the treatment area for up to 5 minutes.
Troubleshooting
Device does not start:
Make sure the device is charged, the indicator
will be flashing with a red light when the battery is low.
Heat energy is not emitted or felt:
Heat will not be emitted if the TREATMENT SURFACE is not touching to your
skin. This is a safety feature.
Do not attempt to open or repair your body device, only authorized personal
are permitted to perform repairs.
Maintenance
After each treatment session, it is necessary to clean your body device, and
specifically concentrating on the TREATMENT SURFACE.
Turn off the body device before cleaning, Use absorbent paper ( such as toilet
paper or hand drying napkins) to gently wipe the gel residue off the TREATMENT
SURFACE. After cleaning, it is recommended to store your •••device in its
original box, and keep it away from water! Never immerse the device into
water.
Specification
Product model
Dimensions| Device size:223155.559MM Base size:160.652.327.lMM
Material| ABS+Metal
Power supply| AC220V /50Hz
Outpnt Voltage/Current| 5V /IA
Battery capacity| 3.7V/2200mAh
Accessories| I Adptor, I USB cable,
1 Clean cloth, 1 manual, 1 bottle of GEL
Certificate of Quality Warranty Card
Product Model| Product Name
Date of Purchase| Purchase Location
Retailer’s Name| Retailer Telephone Nwnber
Retailer’s Address
Problems of the Product
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>