BRIZO T75P606-PCLHP Balance Valve Trim with Integrated Six Function Diverter Instruction Manual

June 1, 2024
BRIZO

BRIZO-LOGO

BRIZO T75P606-PCLHP Balance Valve Trim with Integrated Six Function

Diverter

BRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-Integrated-Six-Function-
Diverter-PRODUCT

Product Information

Specifications

Product Usage Instructions

Installation

  1. Read all instructions before installation.
  2. Ensure the temperature adjustment knob is set by the installer to a safe maximum temperature.
  3. Affix your name, company name, and the date of adjustment on the provided caution label.
  4. Apply the caution label to the back side of the closest cabinet door and the warning label to the water heater.
  5. Leave the Instruction Sheet for the owner’s/user’s reference.

Cartridge Installation

  1. Turn off water supplies.
  2. Remove the cover and rotate the valve cartridge as instructed.

Frequently Asked Questions

Q: What should I do if I need replacement parts?

A: To reference replacement parts and access additional technical documents and product info, visit www.brizo.com.

Q: Can I install a shut-off device on the valve outlet?

A: No, do not install a shut-off device on either outlet of this valve as it may disrupt the valve’s ability to balance hot and cold water pressures.

IMPORTANT DOCUMENTS ENCLOSED

  • CAUTION: To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label.
  • NOTICE TO INSTALLER: Place this label on the water heater next to the temperature adjustment knob.

WARNING:

  • This series of tub/shower valves does not adjust automatically for changes in temperature at the water heater or inlet.
  • If the temperature setting of the water heater or inlet is changed, the setting on these valves must be adjusted manually! Failure to re-adjust the valve may result in hot water burns or extreme cold resulting from variations in line pressure (such as when a dishwasher or washing machine is in use while you are taking a shower). After installation, verify that the temperature knob on the valve is set so that changes in line pressure or temperature do not result in uncomfortable water temperature changes.
  • If the temperature setting of the water heater or inlet is changed after installation of the valve, the setting of the temperature knob also must be changed!
  • Consult the installation instruction sheet for instructions on how to make this setting, or call us at 1-877-345-BRIZO.
  • NOTICE TO INSTALLER: Place this label close to the valve where the owner will see it, such as inside the door of a cabinet or vanity.

WARNING:

  • Water temperature changes due to seasonal or other inlet variations, such as changing the setting on the water heater may require adjustment of the temperature knob on your tub/shower valve to ensure a safe maximum temperature.
  • This valve series does not automatically adjust for inlet temperature changes.
  • If changes occur and you are not sure how to make the necessary temperature knob adjustments, please consult the installation instruction sheet provided with this valve or call 1-877-345-BRIZO.
  • This valve is designed to reduce the risk of injury due to inlet pressure or temperature changes, commonly caused by dishwashers, washing machines, toilets and the like.
  • It may not protect from hot water burns when there is a failure of other temperature-controlling devices elsewhere in the plumbing system.
  • After making the necessary adjustments please fill in the information below. This valve/system has been set by the person listed below to help ensure a safe maximum temperature.
  • Any change in the setting may raise the temperature of the water coming out of the shower or bath above the limit considered safe and could lead to hot water burns.
  • If this label has not been completed, you should verify that the temperature knob has been properly adjusted to suit your installation.
  • The installation instruction sheet supplied with the valve provides information on how to make this setting.

MODELS

TO BE FILLED OUT BY THE INSTALLER

  • BY/POR ___
  • COMPANY ____
  • DATE ___
  • PHONE ___
  • To reference replacement parts and access additional technical documents and product info, visit www.brizo.com
  • 1-877-345-BRIZO (2749) www.brizo.com/customer-support
  • Read all instructions before installation.

CAUTION

  • Failure to read these instructions before installation may result in personal injury, property damage, or product failure.
  • The manufacturer assumes no responsibility for product failure due to improper installation.

TOOLS

You may needBRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-Integrated-Six-
Function-Diverter-FIG-3

  • CAUTION: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe and may lead to hot water burns.
  • NOTICE TO INSTALLER: CAUTION!–As the installer of this valve, it is your responsibility to properly INSTALL and ADJUST this valve per the instructions given.
  • This valve does not automatically adjust for inlet temperature changes, therefore, someone must make the necessary rotational limit stop adjustments at the time of installation and further adjustments may be necessary due to seasonal water temperature changes.
  • YOU MUST inform the owner/user of this requirement by following the instructions.
  • If you or the owner/user are unsure how to properly make these adjustments, please refer to and if still uncertain, call us at 1-877-345-BRIZO (2749).
  • After installation and adjustment, you must affix your name, company name, and the date you adjusted the temperature knob to the caution label provided and apply or attach the label to the back side of the closest cabinet door and the warning label to the water heater. Leave this Instruction Sheet for the owner’s/user’s reference.
  • WARNING: This pressure-balanced valve is designed to minimize the effects of outlet water temperature changes due to inlet pressure and temperature changes, commonly caused by dishwashers, washing machines, toilets and the like.
  • There is a risk of hot water burns and another personal injury when there is a failure of other temperature-controlling devices elsewhere in the plumbing system if the rotational limit stop is not properly set or if the hot water temperature is changed after the settings are made or if the water inlet changes due to seasonal changes.
  • To minimize this risk, caution should be used when using the hot water knob.
  • WARNING: Do not install a shut-off device on either outlet of this valve.
  • When this type of device shuts off the water flow, it can defeat the ability of the valve to balance the hot and cold water pressures.
  • CAUTION: Failure to read these instructions before installation may result in personal injury or property damage.
  • The manufacturer assumes no responsibility for product failure due to improper installation.

INSTALLATION INSTRUCTION

Cartridge InstallationBRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-
Integrated-Six-Function-Diverter-FIG-4

  • Turn off water supplies. Remove cover (1), bonnet nuts (2), and test caps (3) from the rough-in body (4).
  • Place a bucket or small container over the front of the valve body and slowly open the water supplies to flush any debris from the supply lines before installing the cartridge. Turn the water supplies back off.
  • Rotate valve cartridge (1) so the words “HOTTER COLDER” (2) appear on the top. Insert cartridge assembly into rough-in body. A light coating of plumbers grease applied to o-rings may aid in assembly.
  • Make sure the key (3) on the cartridge is fully engaged with the slot in the brass body (4). Insert bonnet nut (5) on the cartridge and thread it onto the body.
  • Hand tighten securely. Slide o-ring (6) over the cartridge and bonnet. A light coating of plumber grease applied to o-rings may aid in assembly.

Back-to-Back Installation

  • For the exceptions of back-to-back or reverse installations (hot on right and cold on left) only: Rotate valve cartridge (1) so “HOTTER COLDER” (2) appears on the bottom.
  • A light coating of plumbers grease applied to o-rings may aid in assembly.
  • Install the cartridge making sure that the keys are fully engaged with the slot in the rough-in body (see step B).
  • Slide o-ring (4) and bonnet nut (3) over the cartridge and thread onto the rough-in body.
  • NOTICE: Over-tightening may lead to property damage or product failure. Hand tighten securely.

Diverter Cartridge InstallationBRIZO-T75P606-PCLHP-Balance-Valve-Trim-
with-Integrated-Six-Function-Diverter-FIG-6

  • FOR DIVERTER CARTRIDGE INSTALLATION: Apply a light coating of plumber grease on the diverter cartridge and sleeve (4) and the o-ring (2) to make the diverter sleeve (3) easier to install on the diverter cartridge.
  • Install diverter cartridge (1) assuring that the locating pin on the bottom of the cartridge aligns with the mating hole in the rough-in body.
  • Slide the diverter sleeve (3) over the cartridge stem aligning tabs on the diverter sleeve with slots in the rough-in body (5).

For Bonnet Installation

  • Slide bonnet nut (1) over diverter sleeve (2) and thread into rough-in body.
  • NOTICE: Over-tightening may lead to property damage or product failure. Hand tighten securely.

Adjusting the Rotational Limit Stop

BRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-Integrated-Six-Function-
Diverter-FIG-7

WARNING:

  • The Rotational Limit Stop is used to limit the amount of hot water available such that, if set properly, a scald injury is less likely to occur if the handle accidentally is rotated to “hot” when a person is showering. The first position allows the LEAST amount of hot water to mix with the cold water in the system. In the first position, the water will be the coldest possible when the handle is turned to hot. As you move the Rotational Limit Stop counterclockwise, you progressively add more and more hot water to the mix. The last position to the left will result in the greatest amount of hot water to the mix, and the greatest risk of scald injury if someone accidentally turns the valve handle to the hot side while showering.
  • WARNING: In some instances, setting the Rotational Limit Stop in the hottest position (fully counterclockwise) could result in scald injury.
  • It is necessary to adjust the Rotational Limit Stop so that the water coming out of the valve will not scald the user when the handle of the valve is rotated to the hot side.
  • According to the majority of industry standards, the maximum allowable temperature of the water exiting the valve is 120°F (Your local plumbing codes may require a water temperature less than 120°F).
  • The Rotational Limit Stop may need to be re-adjusted seasonally if the inlet water temperature changes.
  • For example, during the winter, the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures. The water temperature for a comfortable bath or shower is typically between 90°F – 110°F.
  • Run the water so that the cold water is as cold as it will get and the hot water is as hot as it will get. Place the handle on the stem (see page 8, step 4C) and rotate the handle counterclockwise until the handle stops.
  • Place a thermometer in a plastic tumbler and hold it in the water stream. If the water temperature is above 120°F, the Rotational Limit Stop must be repositioned clockwise to decrease the valve outlet water temperature to be less than 120°F or to meet the requirements of your local plumbing codes.
  • To adjust the temperature of the water coming out of the valve, pull the white Rotational Limit Stop (1) outward and rotate. Clockwise rotation will decrease the outlet temperature, counterclockwise rotation will increase the outlet temperature. Temperature change per tooth (notch) could be 4° – 16°F based on inlet water conditions. Repeat as necessary. When finished, make sure that the Rotational Limit Stop is fully retracted into the seated position.
  • NOTICE: Do not take the Rotational Limit Stop apart.
  • WARNING: TO AVOID THE RISK OF PERSONAL INJURY, MAKE SURE COLD WATER FLOWS FROM THE VALVE FIRST. MAKE SURE WATER FLOWING FROM THE VALVE AT THE HOTTEST FLOW POSSIBLE DOES NOT EXCEED 120°F OR THE MAXIMUM ALLOWED BY YOUR LOCAL PLUMBING CODE.BRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-Integrated-Six-Function-Diverter-FIG-8

Trim Sleeve Installation

  • Insert Spacer (3) into the sleeve (1) and push it to the front. Slide trim sleeve (1) over the bonnet (2), valve cartridge, and rough-in body.
  • Ensure the sleeve is properly positioned over the front of the cartridge.
  • Cylinder trim sleeve (4) does not require a spacer. Ensure the word FRONT points out and slide the trim sleeve over the cartridge.

Escutcheon Installation

  • For finished wall thickness up to 1 1/8″. Secure the backplate (1) to the rough-in body (2) using 4 screws (3) provided.
  • Note: Be sure the backplate is oriented front side forward and markings are visible.
  • Push seal (6) onto the back of the escutcheon (4) valve hole. Slide escutcheon (4) over valve and diverter cartridges, thread trim nut (5) provided onto diverter sleeve.
  • Note: For thick wall installations, order installation kit RP100160 to support finished wall thickness up to 2 1/8″.
  • On rough or uneven surfaces it is necessary to apply caulk around the backplate (1) to supplement the seal. Do not caulk the drip notch in the bottom of the backplate (1). Do not caulk the escutcheon (4).

Handle InstallationBRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-
Integrated-Six-Function-Diverter-FIG-9

Valve Handle Installation

  • Using a hex wrench, install valve handle (1) with screw (2). Applying pressure, insert button if provided (3) until properly seated.

Models with axial screw in handle blade

  • Secure the handle onto the stem using screw and hex wrench or screwdriver as needed. Insert the button into the handle.

Models with sunken handle

  • Install stem extender (1) onto the valve stem and secure with screw (2). Slide the handle onto the stem extender and tighten the set screw (3). Insert button (4) until properly seated.

Diverter Handle Installation

  • Slide diverter handle (1) onto trim sleeve (2). Using a hex wrench, insert set screw (3) into the handle (1). Applying pressure, insert set screw cover if provided (4) until properly seated.
  • WARNING: To minimize the risk of potential scald or thermal shock injury due to cross flow, make sure the shower outlet is not blocked or restricted (e.g., pause control on the showerhead).
  • Also, point the showerhead away from you when re-starting flow or install inlet check valves on both supply lines.BRIZO-T75P606-PCLHP-Balance-Valve-Trim-with-Integrated-Six-Function-Diverter-FIG-10

Maintenance

  • Faucet leaks from tub spout/showerhead: SHUT OFF WATER SUPPLIES.

Replace seats and springs–Repair

  • Kit RP4993. Check the condition of lower O-rings and replace if necessary RP14414. See Helpful Hints 1, 2, & 3.

If the leak persists:

  • SHUT OFF WATER SUPPLIES.
  • Replace valve cartridge RP46074.
  • See Helpful Hints 1, 2, 3 & 5.

Unable to maintain constant water temperature:

  • Replace valve cartridge RP46074 or follow instructions in Helpful Hints 1, 2, 4 & 5.

If water does not flow:

  • Verify that both the hot and cold supplies are fully on and pressurized.

Helpful Hints:

  1. Before removing the valve cartridge assembly for any maintenance, be sure to note the position of the rotational limit stop on the cap. The valve cartridge assembly must always be put back in the same position. BE SAFE! After you have finished the installation, turn on the valve to make sure the COLD WATER FLOWS FIRST.
  2. To remove the valve cartridge from the body, shut off the water supplies and remove the handle and bonnet nut. Do not pry the valve cartridge out of the body with a screwdriver. Place the handle on the stem and rotate counterclockwise approximately 1/4 turn after the stop has been contacted. Lift valve cartridge out of body.
  3. To remove seats and springs, remove the valve cartridge. Separate the cap assembly from the housing assembly by rotating the cap assembly counterclockwise 90o (degrees). Separate cap and housing assemblies. Remove seats and springs and replace them. Place the largest diameter of the spring into the seat pocket first and then press the tapered end of the seal over the spring. Reassemble the valve cartridge and replace it in the body following the instructions given in 1 above.
  4. If the water in your area has lime, rust, sand, or other contaminants in it, your pressure balance valve will require periodic inspection. The frequency of the inspection will depend on the amount of contaminants in the water. To inspect the valve cartridge remove it and follow the steps in note 1 above. Turn the valve to the full mix position and shake the cartridge vigorously. If there is a rattling sound, the unit is functional and can be reinstalled following the instructions given in note 1 above. If there is no rattle, replace valve cartridge RP46074.
  5. Make sure the rotational limit stop is fully seated and retained. Use a disc, if included.

Diverter Handle Reference Sheet

Water Flow For 3-Function DiverterBRIZO-T75P606-PCLHP-Balance-Valve-Trim-
with-Integrated-Six-Function-Diverter-FIG-11

Shared positions do not exist in non-shared cartridges.

Water Flow For 6 Function DiverterBRIZO-T75P606-PCLHP-Balance-Valve-Trim-
with-Integrated-Six-Function-Diverter-FIG-12

Shared positions do not exist in non-shared cartridges.

Cleaning and Care

  • NOTICE: Care should be given to the cleaning of this product.
  • Although its finish is extremely durable, it can be damaged by harsh abrasives or polish.
  • To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
  • www.brizo.com

Documents / Resources

| BRIZO T75P606-PCLHP Balance Valve Trim with Integrated Six Function Diverter [pdf] Instruction Manual
T75P606-PCLHP, T75P606-BNXLHP, T75P606-PCLHP Balance Valve Trim with Integrated Six Function Diverter, T75P606-PCLHP, Balance Valve Trim with Integrated Six Function Diverter, Integrated Six Function Diverter, Six Function Diverter, Function Diverter, Diverter
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRIZO User Manuals

Related Manuals