BRIZO T75680-BL Siderna TempAssure Thermostatic Valve Trim Instruction Manual

June 1, 2024
BRIZO

BRIZO T75680-BL Siderna TempAssure Thermostatic Valve Trim

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-
product

Product Information

Specifications:

  • Series: T60 / T75 Series, T60P/T75P Series, T66T Series
  • Model Numbers : T75580p, T75680p
  • Finish : Specify Finish

Product Usage Instructions

Important Safety Instructions:

  1. To reduce the risk of injury due to hot water burns, ensure that the enclosed labels are applied as specified on the label.
  2. Follow all instructions prior to installation to avoid personal injury, property damage, or product failure.
  3. Do not install a shut-off device on either outlet of the valve to maintain proper water pressure balance.

Installation:

  1. Turn off water supplies.
  2. Remove cover (1), bonnet nuts (2), and test caps (3) from the rough-in body (4) R75000.
  3. Flush any debris from the supply lines by slowly opening the water supplies with a bucket placed over the valve body.
  4. After installation and adjustment, affix your name, company name, and date on the provided caution label and attach it to the cabinet door. Apply the warning label to the water heater.
  5. Leave the Instruction Sheet for the owner’s reference.

Temperature Adjustment:

  1. This system/device must be set by the installer to ensure a safe maximum temperature.
  2. Any change in the setting may lead to hot water burns. Contact customer support at 1-877-345-BRIZO (2749) for assistance.

FAQ

  • Q: What should I do if I need assistance with temperature settings?
    • A : Contact customer support at 1-877-345-BRIZO (2749) for guidance on adjusting the temperature settings safely.
  • Q: Can a shut-off device be installed on either outlet of the valve?
    • A : No, do not install a shut-off device on either outlet as it can disrupt the balance of hot and cold water pressures.

IMPORTANT DOCUMENTS ENCLOSED

CAUTION:
To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label.

NOTICE TO INSTALLER : Place this label close to the valve where the owner will see it, such as inside the door of a cabinet or vanity.

WARNING:

Water temperature changes due to seasonal or other inlet variations, such as changing the setting on the hot water heater may require adjustment of the temperature knob on your tub/shower valve to ensure a safe maximum temperature. This valve series does not automatically adjust for inlet temperature changes. If changes occur and you are not sure how to make the necessary temperature knob adjustments, please consult the installation instruction sheet provided with this valve or call 1-877-345-BRIZO. This valve is designed to reduce the risk of injury due to inlet pressure or temperature changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature-controlling devices elsewhere in the plumbing system.
After making the necessary adjustments please fill in the information below. This valve/system has been set by the person listed below to help ensure a safe maximum temperature. Any change in the setting may raise the temperature of the water coming out of the shower or bath above the limit considered safe and could lead to hot water burns. If this label has not been completed, you should verify that the temperature knob has been properly adjusted to suit your individual installation. The installation instruction sheet supplied with the valve provides information on how to make this setting.

TO BE FILLED OUT BY THE INSTALLER / PARA SER LLENADO POR EL INSTALADOR /
A REMPLIR PAR L’INSTALLATEUR:

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-
fig1,..,.,.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(1\)

Thermostatic

MultiChoice® Valve with Integrated 3 or 6-Function Diverter Trim

T75580p

T75680p

Specify Finish

Register Online
www.brizo.com/customer-support/product-registration

To reference replacement parts and access additional technical documents and product info, visit www.brizo.com

Read all instructions prior to installation.

CAUTION

Failure to read these instructions prior to installation may result in personal injury, property damage, or product failure. The manufacturer assumes no responsibility for product failure due to improper installation.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(3\)

CAUTION: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe and may lead to hot water burns.

NOTICE TO INSTALLER:

CAUTION!– As the installer of this valve, it is your responsibility to properly INSTALL and ADJUST this valve per the instructions given. This valve does not automatically adjust for inlet temperature changes, therefore, someone must make the necessary temperature knob adjustments at the time of installation and further adjustments may be necessary due to seasonal water temperature changes. YOU MUST inform the owner/user of this requirement by following the instructions. If you or the owner/user are unsure how to properly make these adjustments, pleaserefer to page 5 and if still uncertain, call us at 1-877-345-BRIZO (2749).

After installation and adjustment, you must affix your name, company name, and the date you adjusted the temperature knob to the caution label provided and apply or attach the label to the back side of the closest cabinet door and the warning label to the water heater. Leave this Instruction \ Sheet for the owner’s/user’s reference.

WARNING: This thermostatic bath valve is designed to minimize the effects of outlet water temperature changes due to inlet pressure and temperature changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature-controlling devices elsewhere in the plumbing system, if the temperature knob is not properly set or if the hot water temperature is changed after the settings are made or if the water inlet changes due to seasonal changes.

WARNING: Do not install a shut-off device on either outlet of this valve. When this type of device shuts off the water flow, it can defeat the ability of the valve to balance the hot and cold water pressures.

Cartridge Installation

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(4\) Turn off water supplies. Remove cover (1) , bonnet nuts (2) , and test caps (3) from the roughing body (4) R75000. Place a bucket or small container over the front of the valve body and slowly open the water supplies to flush any debris from the supply lines before installing the cartridge. Turn the water supplies back off.

Rotate the valve cartridge (1) so the word “UP” (2) appears on the top. The “H” is on the hot side and the “ C ” is on the cold side. Add silicone lube to the three o-rings (3) shown above to make the cartridge easier to install and remove from the valve body. Insert the cartridge into the valve body as shown. Ensure the keys on the body are fully engaged with the slots in the body (4). A light coating of plumber grease applied to o-rings may aid in assembly

Thread bonnet nut (2) onto the cartridge. Hand tighten securely. Slide o-ring (1) over the cartridge and bonnet.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(6\)

Back to back Installation

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(5\)

For the exceptions of back-to-back or reverse installations (hot on right and cold on left) only: Rotate valve cartridge ( 1 ) so “ H ” is on the hot side and “ C ” is on the cold side and the word “ UP ” ( 2 ) appears on the bottom. Apply silicone lube to the three o-rings shown above to make the cartridge easier to install and remove from the rough-in body. Install the cartridge making sure that the keys are fully engaged with the slot in the rough-in body (see step B). Slide o-ring ( 3 ) and bonnet nut ( 4) over the cartridge and thread onto the rough-in body. Hand tighten securely

Diverter Cartridge Installation

FOR DIVERTER CARTRIDGE INSTALLATION:

Apply silicone lube to the o-ring (2) to make the diverter sleeve (3) easier to install the diverter cartridge.
Rotate the diverter cartridge (1) so the pin is at the bottom for proper installation. Apply silicone lube to the o-rings (4) to make the diverter sleeve (3) easier to install the diverter cartridge. Align the diverter sleeve so that the notches are in the same position as the notches on the rough-in body (5).

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(7\)

Slip-On Installation

Slide bonnet nut (6) over diverter sleeve (3) and thread into rough-in body. Hand tighten securely.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(8\)

Trim Installation

Trim Sleeve Installation

Slide trim sleeve (1) over the cartridge, bonnet (2), and O-ring. Ensure the sleeve is properly positioned over the cartridge with a set screw access hole downward. The O-ring will help keep the trim sleeve securely in position.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(9\)

Escutcheon Installation

Secure backplate (3) to rough-in body (4) using 4 screws (5) provided. Note: Be sure the backplate is oriented front side forward and markings are visible. If mounting to an uneven surface, apply appropriate sealant around the backplate to supplement the rubber seal. Align holes in escutcheon (6) with cartridges and slide escutcheon (6) onto the backplate. Slide sleeve (7) onto escutcheon (6) and secure by threading trim nut (8) onto diverter sleeve. Do not over-tighten. Slide diverter base (9) over trim nut (8). For thick wall installation, an optional extension kit is available to accommodate up to 1″ of additional wall thickness. Order RP100669.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(10\)

Volume Handle Installation

Slide the volume control handle (10) over the cartridge, aligning flat surfaces inside the handle with flat surfaces on the sides of the cartridge. Handle levers should point downward (6 o’clock) in the off position. Secure handle with set screw (11). Note: Set screw should be started in the handle before installing onto the cartridge. Then tighten the set screw by placing an Allen wrench through the access hole in the trim sleeve.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(11\)

Installation and Adjustment of the Temperature Handle. Failure to do so may cause injury. Please complete the following steps carefully

Adjust temperature limit stop

Turn on water supplies; LET WATER RUN AT FULL HOT TO ENSURE WATER IS AS HOT AS POSSIBLE.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(12\)

Place a thermometer in a plastic tumbler and hold tumbler in the water stream. Aligning the splines, place the temperature handle (1) onto the end of the cartridge stem (2). Rotate the handle until the desired maximum temperature is achieved (not more than 120° or lower, as mandated by local plumbing code).
Remove the temperature handle (1). Replace the handle onto the cartridge stem with handle limit stop (4)  against volume handle limit stop (3) , as shown. Secure temperature handle (1) onto valve stem with screw (5). Ensure O-ring (6) is assembled on the handle cap (7). Install the handle cap by pressing it into place on top of the temperature handle (1). Secure cap by tightening screw (8) from the underside of the handle.

Valve Trim Installation

Diverter Handle Installation

Slide diverter handle (1) onto diverter sleeve (2). Using an allen wrench, insert set screw (3) into handle (1). Applying pressure, insert set screw cover (4) until properly seated.

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(13\)

Potential scald or thermal shock injury could result due to cross flow if the outlet at the shower is blocked or restricted (e.g., pause control on the showerhead). Be sure to point the showerhead away from you when re-starting flow or install inlet check valves on both supply lines to prevent possible injury.

Maintenance

Cannot receive more than a trickle of water :

Both hot and cold supply lines must be pressurized. If only one side is pressurized, the system will not allow adequate flow of water.
Faucet leaks from showerhead : Remove the showerhead then turn the water on and off to verify if the cartridge is leaking or the showerhead is draining slowly (the showerhead may need to be cleaned if water drains slowly).

If the leak persists -SHUT OFF WATER SUPPLIES Replace cartridge assembly – RP47201.

Unable to set or maintain mixed water temperature:

SHUT OFF WATER SUPPLIES. Remove handle assembly, trim sleeve, and bonnet nut. Check to make sure the “H” marking on the cartridge aligns with the hot inlet and the “C” marking on the cartridge aligns with the cold inlet to the valve body The thermostatic cartridge cannot function if hot and cold inlets are reversed.

Low flow:

Low flow may be caused by clogged screens within the thermostatic cartridge. To clean the hot and cold screens in the cartridge, follow the steps below:

  1. SHUT OFF WATER SUPPLIES.
  2. Remove the handle assembly.
  3. Unscrew the hex-shaped portion of the cartridge from the brass section of the cartridge. the brass section must be held securely by the flats while the hex is rotated counter-clockwise. Failure to secure the brass section while rotating the hex can result in damage to the cartridge.
  4. Carefully clean any debris from the screens under running water. If the debris is difficult to remove then soak the screens overnight in a 50% water and 50% vinegar solution.
  5. Reassemble the cartridge.
  6. Replace the handle.
  7. Turn the water back on.
  8. Reset the limit stop before using the valve.

Cleaning and Care

  • Care should be given to the cleaning of this product. Although its finish is extremely durable, it can be damaged by harsh abrasives or polish.
  • To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.

Diverter Handle Reference Sheet

Water Flow For 3-Function Diverter

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(14\)

  • Shared positions do not exist in non-shared cartridges.

Water Flow For 6 Function Diverter

BRIZO-T75680-BL-Siderna-TempAssure-Thermostatic-Valve-Trim-fig
\(15\)

  • Shared positions do not exist in non-shared cartridges.