Doorking RS-232 Converter Kit User Manual
- June 1, 2024
- DOORKING
Table of Contents
Doorking RS-232 Converter Kit
WIRING FOR 1830-186 TCP/IP Server Mode to RS-232 CONVERTER KIT
Connection via Internet
General Information
Use these instructions when using the TCP/IP adapter, part number 1830-186. This is a Plug and Play device (no manual setup required) and uses the DKS Data subscription service. For manual setup (no subscription required), use TCP/IP adapter part number 1830-185.
NOTE: THIS DEVICE IS NOT COMPATIBLE WITH CELLULAR NETWORKS.
You can use the 1830-186 Converter Kit with the following DKS Systems: 1833, 1834, 1835, 1837, 1838 with REV Z board (or higher). 16.5 VAC power is required at the Aux Terminal pins 1 and 2 in the 1830 Series controller: Refer to these manuals for detailed 1830 Series wiring information: P/N 1834-065 or P/N 1835-065 Telephone Entry Systems Installation Manual
Connect Converter to 1830 Series Circuit Board RS-232 Terminals
Connection via LAN
Programming Instructions when using the 1830-186 Plug & Play TCP/IP
Converter Kit
At the Programming Computer (PC Only)
- Install the Remote Account Manager software version 6.3.i on the programming PC and register the software by following the on screen instructions.
- Choose IM / DKS VoIP to register for a Data over IP or VoIP Voice + Data subscription.
- Complete the required contact information and then click Register.
- Select the first choice.
Setup the 1830 Series Entry System for Data over IP
- In Service Type, choose Data over IP.
- A 10 digit ID number will be generated for you. Enter the system Master Code.
- The Master Code can only be programmed at the entry
system. Enter that Master Code here).
Setup an Account in the Remote Account Manager Software 6.3.
- Connection Option, choose Data over IP.
- Enter the 10 digit ID number that was generated for you.
- Enter the system Master Code that was set at the entry system.
Program the 10-Digit Telephone Number / System ID at the Entry System
Program the 10 Digit ID Number at the entry system keypad:
- 59_-__ (Master Code) (beep).
- Enter the 10 Digit ID Number _ – then press * (beep).
- Press 0 # together to exit the programming sequence (beeeeeep).
To test the connection at the entry system:
- *29 – - (Master Code). The system will respond with:
- 1 beep – display reads “System is Registered” You’re Done!
- 2 beeps – display reads “Check Registration” Communication to the server