Doorking RS-232 Converter Kit User Manual

June 1, 2024
DOORKING

Doorking RS-232 Converter Kit

WIRING FOR 1830-186 TCP/IP Server Mode to RS-232 CONVERTER KIT

Connection via Internet

Doorking-RS-232-Converter-Kit-fig-1

General Information

Use these instructions when using the TCP/IP adapter, part number 1830-186. This is a Plug and Play device (no manual setup required) and uses the DKS Data subscription service. For manual setup (no subscription required), use TCP/IP adapter part number 1830-185.

NOTE: THIS DEVICE IS NOT COMPATIBLE WITH CELLULAR NETWORKS.

You can use the 1830-186 Converter Kit with the following DKS Systems: 1833, 1834, 1835, 1837, 1838 with REV Z board (or higher). 16.5 VAC power is required at the Aux Terminal pins 1 and 2 in the 1830 Series controller: Refer to these manuals for detailed 1830 Series wiring information: P/N 1834-065 or P/N 1835-065 Telephone Entry Systems Installation Manual

Connect Converter to 1830 Series Circuit Board RS-232 Terminals

Doorking-RS-232-Converter-Kit-fig-2

Connection via LAN

Doorking-RS-232-Converter-Kit-fig-3

Programming Instructions when using the 1830-186 Plug & Play TCP/IP

Converter Kit

At the Programming Computer (PC Only)

  1. Install the Remote Account Manager software version 6.3.i on the programming PC and register the software by following the on screen instructions.Doorking-RS-232-Converter-Kit-fig-4
  2. Choose IM / DKS VoIP to register for a Data over IP or VoIP Voice + Data subscription.
  3. Complete the required contact information and then click Register.Doorking-RS-232-Converter-Kit-fig-5
  4. Select the first choice.

Setup the 1830 Series Entry System for Data over IP

  1. In Service Type, choose Data over IP.
  2. A 10 digit ID number will be generated for you. Enter the system Master Code.
  3. The Master Code can only be programmed at the entry
    system. Enter that Master Code here).

Doorking-RS-232-Converter-Kit-fig-6

Setup an Account in the Remote Account Manager Software 6.3.

  1. Connection Option, choose Data over IP.
  2. Enter the 10 digit ID number that was generated for you.
  3. Enter the system Master Code that was set at the entry system.

Doorking-RS-232-Converter-Kit-fig-7

Program the 10-Digit Telephone Number / System ID at the Entry System

Program the 10 Digit ID Number at the entry system keypad:

  1. 59_-__ (Master Code) (beep).
  2. Enter the 10 Digit ID Number _ – then press * (beep).
  3. Press 0 # together to exit the programming sequence (beeeeeep).

To test the connection at the entry system:

  1. *29 – - (Master Code). The system will respond with:
    • 1 beep – display reads “System is Registered” You’re Done!
    • 2 beeps – display reads “Check Registration” Communication to the server

Summary

Doorking-RS-232-Converter-Kit-fig-8

Documents / Resources

| Doorking RS-232 Converter Kit [pdf] User Manual
RS-232 Converter Kit, RS-232, Converter Kit, Kit
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DOORKING User Manuals

Related Manuals