Warning and safety instructions

  • The battery in this product complies with the relevant IEC safety standards for batteries.
  • Please read the safety instructions on the power supply before use.
  • The power supply unit must meet the relevant IEC safety standards.
  • The battery must not be replaced, and the product must be sent for repair.
  • The product must not be disassembled. Risk of electric shock!
  • Read the intended use before putting it into service.

Intended use

RP902 is a repeater unit for our Mater Repeater system.

RP902 unit will be able to extend the range of the system. Up to 14 repeaters can be added to a system.

RP902 has no independent functions, it only works if there is a master unit.

Commissioning

RP902 only needs to be connected to a 230V socket. No wiring is needed between the units.

The unit switches on automatically when it is connected to the electricity supply network.

The LED

The LED is either green or red when lit.

RED: Error, no connection
RED flashing: Battery status.
GREEN: Connection and OK.
GREEN flashing: Confirmation of the answer.
No light: The device is switched off.

Backup

The RP902 has an internal backup battery that keeps the system running in case of power failure.

The battery lasts for a few hours. If necessary, the battery can be recharged (a full charge takes about 24 hours).

If the battery cannot be replaced, contact your retailer for battery service.

Configure

Before use, the RP902 must be connected to the system. This must be done in the MR902 unit.
See the MR902 user manual on how to do this.

Service

RP902 has four primary buttons, these are for future use.

F4, on the other hand, is for shutting down the unit, usually before transport or long-term storage.

Shutdown: disconnect RP902 from the electric power supply by pressing and holding F4 for about 5 seconds until it flashes RED.

Maintenance

Software update:
It is possible to update the RP902 software. For a more detailed description, please check the KNOPtool.

Cleaning

The product can be cleaned with a moist cloth or a wet wipe.

Technical data

Frequency HF: 869.2125 MHz
Range: Up to 1500 metres between MR902/RP902 and RP in free view. (1)
Range in a building: Recommended distance between repeater units <25m

Power supply: 230VAC
Connection plug: 2-pole EURO

Battery: Lithium battery, LP853048 3.7V 1200mA
Battery time: Approximately 4 hours
Charge: Approximately 1 day

Surrounding environment: Indoor use. ≤ 90% non-condensing
Ambient temperature: 0°C to +40°C

Cabinet type: Color RAL9001 ABS
Cabinet dimensions: Ø110mmx52mm

Desnity: IP40
Weight: 135g

The right to make changes is reserved.

All rights reserved.
© KNOP Elektronik A/S

Measured outdoors with an unobstructed view between transmitter and receiver. In buildings the range is reduced.

Explanation of symbols and approvals

| This product complies with MDR 2017/745/EU on medical devices.
---|---
| This product complies with directives REACH 1907/2006/EU & RoHS 2011/65/EU.

__

__

| This product complies with these electrical safety and EMC directives: EN 301 498-1 V2.2.3 Electro Magnetic Compatibility
EN 301 489-3 V3.1.1  Electro Magnetic Compatibility EN 50130-4:2011 + 2014 Immunity alarm systems
EN 300 220-1 V3.1.1  Short Range Devices EN 300 220-2 V3.1.1  Short Range Devices EN 300 220-3 V2.1.1    Short Range Devices
EN 60601-1-2:2014 + 2015 Electromagnetic compatibility (Medical) EN 62368-1:2020 Electrical safety
EN 50581:2012  Hazardous substances
| The product must not be used if the packaging is damaged.
| Medical Device

Class 1

| Manufacturer

Knop Elektronik A/S, Fabriksvej 20, DK-7600 Struer

| Read the manual(s) before installation and commissioning.
| Interference may occur in an environment with equipment marked with this symbol.
| Can be protected against liquids before installation.
| 0 °C to +40 °C, temperature limit for transport/storage and use.
| The product must not be disposed of with normal household waste.
| Single Registration Number

DK-MF-000025631

| Unique Device Identifier

05744002850342

| Products reference

RP902, Repeater

| Serial Number

Placed on the product

| Ingress Protection kode

IP40