  • Q: Can the fixture be installed with the socket facing downwards?
    • A: No, the fixture should be installed with the socket facing UP as shown in the diagram.
  • Q: What type of drill bit should be used for wall anchors?
    • A: For studs, use a 3/32 drill bit. For non-stud locations, use a 3/16 drill bit for wall anchors.
  • Q: How should wire connections be made?
    • A: Refer to the provided chart for correct wire connections based on the wire type and color.

FIXTURE DIAGRAM

KICHLER-52694CPZ-Alvaro-12-Tall-Bathroom-Sconce-fig-1

PARTS LIST

  • [A] Mounting Screw (2)
  • [B] Canopy
  • [C] Wall Anchor Screw (2)
  • [D] Wall Anchor (2)
  • [E] Strap Mounting Screw (2)
  • [F] Mounting Strap
  • [G] Outlet Box (not supplied)

PRECAUTIONS

CAUTIONS

CAUTION:  RISK OF SHOCK:

Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

WARNING:

  1. This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

CLEANING:

  • Always be certain that electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

INSTALLATION INSTRUCTIONS

  1. NOTE: Fixture should be installed with socket facing UP as shown.

    • Using the strap mounting screws[E], attach mounting strap[F] to outlet box[G].
    • NOTE: Mounting strap should be installed with the flat side of the mounting strap against the wall, and with the holes for the mounting screws[A] at the 12 and 6 o’clock position as shown.
  2. Using the mounting strap as a template, mark the positions for the additional wall mounting locations through the holes near the top and the bottom of the mounting strap.

  3. Carefully remove strap mounting screws and mounting strap from outlet box.

  4. If additional wall mounting location is on a stud, use a 3/32” drill bit (not included) to drill a pilot hole into wall. If additional wall mounting location is not on a stud, use a 3/16” drill bit (not included) to drill a hole for a wall anchor[D] into wall. Insert a wall anchor into hole, and lightly tap wall anchor into mounting surface until flush.

  5. Using the strap mounting screws[E], reattach mounting strap[F] to outlet box[G]. Tighten to secure.

  6. Secure mounting strap to wall by screwing the two (2) wall anchor screws[C] into the additional wall mounting locations. Tighten to secure.

  7. Grounding instructions: (See Illus. a or b).KICHLER-52694CPZ-Alvaro-12-Tall-Bathroom-Sconce-fig-2

  8. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.

  9. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
    If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.

  10. Make wire connections. Reference chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    *Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

  11. Push canopy[B] to wall, carefully aligning the mounting screw holes in the top and bottom of the mounting strap with the mounting screw holes in the top and bottom of the canopy.

    • NOTE: Make sure all wires are inside canopy and do not get pinched between mounting strap and canopy or wall and canopy of fixture.
  12. Screw two (2) mounting screws[A] into holes in canopy and mounting strap to attach fixture to wall. One at the top and one at the bottom of the canopy. Tighten to secure.

  13. Insert recommended bulb(s) (not included).