Lumens HDL410 CamConnect Pro Setting User Guide
- June 1, 2024
- Lumens
Table of Contents
Lumens HDL410 CamConnect Pro Setting
Product Specifications
- Product Name: Nureva HDL410 & CamConnect Pro
- Supported Room Types: Meeting room, classroom, open space, and others
- Ports: HDL410 – Port 1 and Port 2, CamConnect Pro – Port 8931
- Default IP Address: Nureva HDL410 – Example: 192.168.11.27,CamConnect Pro – Example: 192.168.11.11
- Audio Trigger Level: CamConnect Pro – 65 (adjustable)
- Room Coverage: HDL410 optimized performance for reduced reverberations, echoes, and background noise
Product Usage Instructions
Nureva HDL410 Setup
Enrolling HDL410
To enroll HDL410, follow these steps:
- Access the Nureva console at https://www.nureva.com/software-and-services/console
- Enter the enrollment code located at the bottom of the console hardware
- Follow the prompts to enter room level details
HDL410 Room Level Settings
To set up HDL410 in a room:
- Define the room type (e.g., Meeting room, classroom)
- Access room level settings by clicking on the room name in the rooms section
- Edit and define room dimensions for optimum performance
- Fine-tune room in relation to seating arrangements and HDL410 ports
- Recalibrate HDL410 in the defined room after making any room-level changes
CamConnect Pro Settings
Connecting CamConnect with HDL410
To connect CamConnect with HDL410:
- Allow HDL410 to send data to CamConnect using port 8931 and CamConnect’s IP address
- Select HDL410 from the device dropdown list
- Enter HDL410’s IP address and set the connect toggle bar to the right
- Fine-tune and map seating positions with azimuth angles in CamConnect
Frequently Asked Questions (FAQ)
Q: How can I optimize the performance of HDL410 in different room types?
A: You can optimize HDL410 performance by defining room dimensions
accurately, fine-tuning port positioning based on the environment, and
recalibrating after any room level changes.
Q: What is the default port for connecting CamConnect Pro with HDL410?
A: The default port for connecting CamConnect Pro with HDL410 is port
8931.
Discovering/ Enrolling HDL410
Preface:
- Accessing Nureva Console
- Enrolling HDL410 (console method)
- Editing/defining room dimensions
Access and enroll HDL410
Access Nureva console: https://www.nureva.com/software-and- services/console
Note: There are 2 methods to enroll; 1. USB method and 2. Nureva console. (Nureva console is shown here)
- For USB method see here (console client) : https://support.nureva.com/faqs-nureva-console/generate-enrollment-code-with-nurevaconsole-client
Enrolling HDL410 (console):
- enter your enrollment code (located at the bottom of console- hardware).
- You will be prompted to enter room level details- see next section
HDL410 Room Level Settings
Preface:
- Defining room type
- Accessing room level settings
- Editing/defining room dimensions
- Defining Room Dimensions for optimum performance
- Fine tuning room in relation to seating arrangements and HDL410 ports
- Recalibrating HDL410 in defined room
Setting up HDL410 in room (room level settings)
Defining room type:
- Shown below is [type =Meeting room]. HDL410 supports up to 8 types (classroom, open space and others).
Accessing room level settings;
- Your newly created room will appear in rooms section, click on [room name] to access.
Editing/defining room dimensions: (HDL40 works as if were a single unit.)
Defining Room Dimensions for optimum performance: (this will take you to room coverage map)
Important:
- Measure your room space and place HDL410 port 1 and 2 as precise as possible.
- In my demo, the actual room size is bigger than the defined dimensions. For optimized performance ( to reduce reverberations, echos and background noise).
Fine tuning room in relation to seating arrangements and HDL410 ports:
- An example for depiction purposes only is shown here, adjust your HDL410 port positioning as needed based on environment and usage scenario.
- The blue spots shows noise or voice source detection.
Recalibrating HDL410 in defined room:
Note: After enrolling and defining room level settings, recalibrate HDL410 in finished room. This ensures all settings are kept and HDL410 “is aware” of environmental/room level changes.
General rule = If there are room level changes, recalibrate your HDL410.
CamConnect Pro (AI-BOX1) Settings
Connected State_AiBox and HDL410
Preface:
- Allow HDL410 to send data to CamConnect
- Three Basic connection Steps
- Fine tuning and mapping of seating positions (Azimuth angles in CamConnect) with HDL410
Connecting CamConnect with HDL410
Allow HDL410 to send data to CamConnect.
- Use port [8931] & enter Camconnect`s IP address [Ex. 192.168.11.11].
Nureva default port is 8931. Please confirm the port is allowed to connect with your PC.
Three Basic connection Steps:
Below items are found under [Supported Device & Settings] HDMI/Web interface.
- From Device drop down list select = HDL410.
- Enter HDL410`s IP address = [example : Device IP = 192.168.11.27]. IP of HDL410 can be found as shown in 3.1.
- Connect toggle bar set to connect = [Connect = move toggle to right].
Fine tuning and mapping of seating positions (Azimuth angles in Camconnect) with HDL410.
- In Advanced setting of CamConnect; set the [Audio Trigger level = 65] or stay close to 60 depending on environment.
- Camconnect automatically provides 8 Azimuth Angles (these angles are adjustable for fine tuning per environment).
- In my example; I show only 4 azimuth Angles in operation; voice source is detected at [-35 ~ -18 ] then VC-TR40N preset 1 is used to capture talker/voice source.
- Map and Adjust your azimuth angle and seating arrangements per environment, use “heat map” in Coverage map.
Thank You!