Lumens VC-TA50 Auto Tracking PTZ Camera Datasheet

June 4, 2024
Lumens

VC-TA50 Auto Tracking PTZ Camera
Datasheet

Connections

Lumens VC-TA50 Auto Tracking PTZ Camera - Figure 1

SWITCH Settings

2.1 OUTPUT SWITCHLumens VC-TA50 Auto Tracking PTZ Camera - Figure
2

2.2 IR SELECT
Configure IR SELECT to control 3 cameras using the remote controllerLumens
VC-TA50 Auto Tracking PTZ Camera - Figure 3

2.3 Camera Address Selector

Setting Function Descriptions
0~7 ID 0~7
8~9 Reserved

2.4 System Switch

Setting Function Descriptions
DIP 1 RS-232C/RS-422 selector

OFF: RS-232C/ON: RS-422
DIP 2| Infrared signal output switch
OFF: Off /ON: On
DIP 3| Communication baud rate selector
OFF: 9600 / ON: 38400
DIP 4| Reserved

Precautions for Installation

  1. Use the provided DC 12V power cord or a PoE router or hub to supply power via a network cable.
  • VC-TA50 supports PoE+ (IEEE802.3at) 2. Tracking distance range: 4m-15m. The optimal tracking distance is 8m. 3. Vertical mounting height: 2m-3m, Optimal installation height: 2.4m.
    Lumens VC-TA50 Auto Tracking PTZ Camera - Figure 6* For best tracking results, avoid placing images of people on posters or screens behind the subject.

Ceiling Installation

  1. Please adjust the resolution on SWITCH prior to installation.
    (Please refer to) SWITCH Settings

  2. Fix base plate A to the camera with 4x silver-colored M3 screws.
    Lumens VC-TA50 Auto Tracking PTZ Camera - Figure 7

  3. Screw ceiling plate B to the ceiling
    *Caution:
    (1) This should be undertaken in accordance with guidelines.
    (2) Do not obstruct the cable passing thru the hole

  4. Attach base plate A to the camera base plate B
    ▼Push base plate A up to the ceiling and slide to the right to latch on to plate B.
    ▼Secure with 2x M3 silver screws and 1x M3 black screws.

  • After the camera is inverted, press the [Mirror] button on the remote control to flip the screen [Flip] Lumens VC-TA50 Auto Tracking PTZ Camera - Figure 8

Start Tracking

  1. Press the remote control to start the auto-tracking function
    *Power LED flashes green when the tracking function of the camera is activated
Items Button Name Function
1 Auto Tracking Enable/Disable Auto Tracking
2 Full When the presenter’s full body is framed by the camera
3 Upper When the speaker’s torso is framed by the camera
4 Switch Force switch to a different presenter
  • For advanced tracking, please download the VC-TA50 User Manual from the Lumens website

Webpage Settings

  1. Open your web browser and enter the IP address in the address bar.
  • The IP address can be verified on a connected monitor by clicking [MENU] =>[Ethernet] => [IP Address] on the remote control

  • If the camera is not connected to a DHCP router, the default IP address is 192.168.100.150

    1. Enter the user name and password to view the camera images, control the camera and manage advanced settings.
      User Name: admin
      Password: 9999
  • Please visit YouTube [My Lumens] channel to watch the related videos for instructions

https://www.youtube.com/c/MyLumens

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lumens User Manuals

Related Manuals