VEVOR LD-HS1 Human Body Teaching Models User Manual
MODEL:LD-HS1 LD-HS2 LD-HS3
NEED HELP? CONTACT US!
Have product questions? Need technical support? Pleasefeel freetocontact us:
Technical Support and E-Warranty Certificatewww.vevor.com/support
This is the original instruction, please read all manual instructionscarefully
before operating. VEVOR reserves a clear interpretationofouruser manual. The
appearance of the product shall be subject totheproduct you received. Please
forgive us that we won’t informyouagainifthere are any technology or software
updates on our product.
SAFETY INSTRUCTIONS
WARNING:
- Read this instructions before using this product. Failuretodosocanresult in serious injury.
- After use, please assemble all the parts and keep themvertically.
- Avoid high temperature and direct sunlight.
- Remove minor stains with neutral detergent. The use of alcohol, benzeneand other substances may damage the product
SAVE THESE INSTRUCTIONS
INSTRUCTIONS
Installation method:
Step 1: Take the arm model, infusion tube, bracket and other accessories out
of the box.
Step 2: Tighten the fixing nut to fix the bracket on the hole position of the
tray.
Step 3: Blood simulation: add red powder and water to prepare red ink, and
then pour it into the hanging bottle (or container)
Blood draw steps:
Step 1: Close one of the pipe clamps (A1) on the arm
Step 2: After the syringe draws the red ink, fill the other hose (A2) with red ink, and immediately close the pipe clamp(A2) .
Step 3: Hold an empty syringe and stab it into one of the veins on the arm. Draw blood, and you can see the red liquid entering the syringe.
Note:
If the red ink does not enter the syringe.
The reason as follow:
a. The vein was completely punctured:;
b. The injected red ink is insufficient;
Blood Transfusion:
Step 1: First, the infusion bottle is filled with red ink, hanging it on a stand then turn off the flow regulator.
Step 3: The butterfly needle is accurately inserted into the vein of the arm, turn on the flow regulator, the red fluid flows out of the venous tube A2 after circulating in the venous tube. (Use the appropriate container to liquid)
Note:
If the red ink does not outflow from the vein A2.
The reason is as follow:
a. The vein was completely punctured;
b. The injected red ink is insufficient;
c. The A1 pipe clamp isn’t hung
on the bracket (need hang it as picture show)
Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai
Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD NSW 2122 Australia
Imported to USA: Sanven Technology Ltd.Suite 250, 9166 Anaheim Place, Rancho
Cucamonga, CA 91730
Made In China
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>