VEVOR BT-WL10A Shutter Exhaust Fan User Manual

October 30, 2023
VEVOR

VEVOR BT-WL10A Shutter Exhaust Fan

We continue to be committed to providing you tools with at a competitive prices. “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean covering all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.

NEED HELP? CONTACT US!

Have product questions? Need technical support? Please feel free to contact us:

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USING THE EQUIPMENT

SAFETY PRECAUTIONS

WARNING Read all safety warnings, instructions, illustrations and specifications provided with this electrical appliances. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.VEVOR-BT-
WL10A-Shutter-Exhaust-Fan-FIG-1 VEVOR-
BT-WL10A-Shutter-Exhaust-Fan-FIG-2 VEVOR-
BT-WL10A-Shutter-Exhaust-Fan-FIG-3

PRODUCT DESCRIPTION

TECHNICAL PARAMETER

Brand ****
Model BT-WL10A
Voltage 120 V
Frequency 60 Hz
Power 25 W
Pack Size(CM) 34.534.522

50.523.850.5
N. W| 2.7 KG| 4.1 KG| 4.6 KG| 6.0 KG
G. W| 3.45 KG| 4.5 KG| 5.5KG| 6.7 KG

PRODUCT STRUCTURE DIAGRAM

VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-4

INSTALLATION

TIPS!Prepare tools in advance: Small wrench,Hammer

VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-5VEVOR-
BT-WL10A-Shutter-Exhaust-Fan-FIG-6

Before commencing assembly familiarize your self with all the assembly components and dimensions (See chart and diagram in Fig.1.)

Installation method

  1. The product shall be installed at least 3-5 meters above the ground for ventilation
  2. Make a hole on the wall with the size of A2xB2. (Refer to Fig.1. )
  3. Punch four holes in the wall,You can choose four holes with the size of Chart A3 or four holes with the size of B3; (Refer to Fig.1.)
  4. Then install the four expansion bolt,You can choose to install indoors or outdoors (Refer to Fig.2.)
  5. Put the product on and lock it with nuts.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-7
  6. Finally connect the lines correctly, (Refer to WIRING DIAGRAM)
    Note: Make sure the product is firm and the wiring is right before power on

POWERING AND SETUP

Step 1:
Plug the fan’s 3-pin connector into the universal controller’s out 1 or out 2 port signified by the fan/power symbol.Plug the sensor’s 4-pin connector into the controller’s sensor signified by the controller symbol.See the(Fig.3 .)VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-9

Step 2:
Lastly, to power both the fan and controller, plug the fans power cord into an AC power outlet.See the(Fig.4.)

Tips:
Smart controllers with EC motors can support two fans of any size. The two EC- motor fans must be plugged in to an outlet to power the fans and the controller. See the images below.

VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-11

CLEANING

  1. Be sure to unplug from the electrical supply source before cleaning.
  2. Plastic parts should be cleaned with mild soap and damp cloth or sponge. Thoroughly remove the soap film with clean water.
  3. Be sure not to get water or other liquid into the motor.

PROGRAMMING

BUTTON DESCRIPTION

VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-12

MODE BUTTON
Cycles through the controller’s temperature/humidity programming: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings).

UP / DOWN BUTTON
Adjusts the settings of the mode that you are in. Up button raises and down button lowers. Hold both to turn off triggers.

LEAF BUTTON
Turns the screen off while programs run in the background. Hold for two seconds to lock or unlock the LCD display.

PROBE TEMP
Displays the current temperature that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in.

CONTROLLER MODE
Displays the mode that the controller is currently in.Pressing the mode button cycles through the modes.

ALERT ICONS
Displays the alerts and statuses from the controller, including the alarm and the screen lock.

PROBE HUMIDITY
Displays the current humidity that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in.

FAN SPEED
Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in.

SETTING
Displays the value you set for the current mode. Pressing the up or down button changes the value.

OPERATION DESCRIPTION

MODE SETTING
Pressing the Mode button will cycle through the controller’s available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings).

ON MODE
In this mode, the fan will heat continuously regardless of temperature or humidity. Use this mode to set the fan’s maximum blowing strength, ranging from 0-10, when triggers are activated.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-13

OFF MODE
In this mode, the fan will not run regardless of temperature or humidity. Pushing the up or down button will change the display’s brightness, ranging in 1/2/3/A3. On setting A3, the display will dim its brightness down to 1 if the device is left unattended for 30 seconds. Holding the up or down button will change the display’s units to F or C, respectively.VEVOR-BT-WL10A-Shutter-
Exhaust-Fan-FIG-14

TIMER MODE
In this mode, pressing the up or down button will set the timer. The fan will ramp up to ON Mode’s setting until the timer’s clock runs out. It will begin spinning 5 seconds after the timer is set. Leaving the timer mode while it’s running will pause it until you return to this mode.VEVOR-BT-WL10A-Shutter-
Exhaust-Fan-FIG-15

TRIGGER MODE: HIGH TEMPERATURE
In this mode, pressing the up or down button sets the high temperature trigger. The fan will activate if the probe’s reading meets or exceeds this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading falls below your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together. You may set this trigger below the low- temperature trigger to create a range where the fan is active.VEVOR-BT-
WL10A-Shutter-Exhaust-Fan-FIG-16

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

TRIGGER MODE: LOW TEMPERATURE
In this mode, pressing the up or down button sets the low temperature trigger. The fan will activate if the probe’s reading meets or falls below this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading rises above your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together. You may set this trigger above the high temperature trigger to create a range where the fan is active.VEVOR-BT-
WL10A-Shutter-Exhaust-Fan-FIG-17

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

TRIGGER MODE: HIGH HUMIDITY
In this mode, pressing the up or down button sets a high humidity trigger. The fan will activate if the probe’s reading meets or exceeds this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading falls below your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together. You may set this trigger below the low humidity trigger to create a range where the fan is active.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-18

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

TRIGGER MODE: LOW HUMIDITY
In this mode, pressing the up or down button sets the low humidity trigger. The fan will activate if the probe’s reading meets or falls below the trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading rises above your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together. You may set this trigger above the high humidity trigger to create a range where the fan is active.VEVOR-BT-WL10A-Shutter-
Exhaust-Fan-FIG-19

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

ALARM SETTING: HIGH TEMPERATURE
In this mode, pressing the up and down button sets a high-temperature alarm. The alarm will sound and its icon will flash if the probe’s reading exceeds the set temperature. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading falls below the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. You may set this alarm below the low-temperature trigger to create an operating range.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-20

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: LOW TEMPERATURE
In this mode, pressing the up and down button sets a low-temperature alarm. The alarm will sound and its icon will flash if the probe’s reading falls below the set temperature. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading rises above the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. You may set this alarm above the high-temperature trigger to create an operating range.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-21

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: HIGH HUMIDITY
In this mode, pressing the up and down button sets a high humidity alarm. The alarm will sound and its icon will flash if the probe’s reading exceeds the set humidity. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading falls below the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. You may set this alarm below the low humidity trigger to create an operating range.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-22

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: LOW HUMIDITY
In this mode, pressing the up and down button sets a low humidity alarm. The alarm will sound and its icon will flash if the probe’s reading falls below the set humidity. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading rises above the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. You may set this alarm above the high humidity trigger to create an operating range.VEVOR-BT-WL10A-Shutter-Exhaust-Fan-
FIG-23

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

FAHRENHEIT OR CELSIUS
To switch between Fahrenheit and Celsius readings, set the controller to OFF Mode. Hold the up button to switch to Fahrenheit (°F) and the down button to switch to Celsius (°C).

DISPLAY BRIGHTNESS
To adjust the brightness of the display, set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. The brightness range is 1/2/3/A3.

TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, press the MODE and UP button simultaneously. This can be done while the controller is any mode. The calibration cycle ranges from -8°F to 8°F (or -4°C to 4°C). You may use this setting to match the controller’s temperature reading with your thermostat’s reading.

HUMIDITY CALIBRATION
To adjust the probe sensor’s humidity reading, press the MODE and DOWN button simultaneously. This can be done in any mode. The calibration cycle ranges from -8% to 8%.

CONTROLLER LOCK
To lock the controller and prevent accidental setting changes, hold the LEAF button for three or more seconds. While the display is locked, you will not be able to switch modes or adjust settings. You will only be able to put the controller in ECO display. Holding the LEAF button for three or more seconds will unlock the controller.

ECO-MODE
To turn off the LCD display, press the LEAF button. While the screen is off, all programs, settings, and alarms will run in the background. You can activate ECO Mode while the controller is locked. To exit ECO mode, press any button.

ALERT ICONS
The top left of the display shows the alert icons. Icons may flash when the controller signals an alert to tell you a particular function or alarm is being triggered.

VEVOR-BT-WL10A-Shutter-Exhaust-Fan-FIG-24VEVOR-
BT-WL10A-Shutter-Exhaust-Fan-FIG-25

  • Manufacturer: Bote electric appliance(Guangdong)Co., Ltd Address: 5TH floor, No.28, area 1, Sanlian Industrial Zone, Gulao Town, Heshan City, Jiangmen,Guangdong Made In China