RAB HIDFA 115S-V-EX39-8CCT-BYP-3SP-INST Series High Bay Instructions

June 12, 2024
RAB

RAB HIDFA 115S-V-EX39-8CCT-BYP-3SP-INST Series High Bay

RAB Lighting 1s committed to creating high quality, affordable well designed and energy efficient LED l1ght1ng and controls that make 1t easy for electnc1ans to install and end users to save energy We’d love to hear your comments Please call the Marketing Department at 888 RAB 1000 or email market1ng@rablighting com

HIDFA-115S-V-EX39-8CCT-BYP/3SP

Our sensor product numbers include MW-5/SMW-5, PIR-5/SPIR-5 and DAYLIGHT-5 are optional accessories for select High Bay lamps. The lamps will perform as normal if no sensor is inserted. Please note that RAB lamps can’t operate with other brand sensors.RAB-HIDFA-115S-V-EX39-8CCT-BYP-3SP-INST-Series-High-Bay
\(2\)

IMPORTANT

READ CAREFULLY BEFORE INSTALLING LED HID BULBS. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB LED HID Bulbs must be wired in accordance with the National Electrical Code and all applicable codes.Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS:

  • Main applications include for use in high bay and other suitable light fixtures.
  • Operating temperature:-30°Cto 60°C (-22°F to 140°F).
  • These LED Lamps require all ballasts, capacitors, and ignitors to be bypassed or removed. Do not operate lamps on existing ballasts.
  • Dimmable with optional control modules.
  • Do not use with standard dimmers. Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard( incandescent) dimmer or dimming control.
  • This device is not intended for use with emergency exits.
  • For use in enclosed fixtures.
  • Before installation make certain the AC power to the fixture is off.
  • Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.
  • Risk of fire or electric shock. LED Retrofit lamp installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • Use only with a portable luminaire that is provided with a shade.
  • Added weight of the device may cause instability of a free-standing portable luminaire.
  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERETHE SUITABILITY OF THE
    COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Burning positions

base up

You must use the safety cable to tight the lamps in case of falling down due to old socket

SELE (TAB IL ITY Power and CCT Selectable

RAB-HIDFA-115S-V-EX39-8CCT-BYP-3SP-INST-Series-High-Bay
\(4\)

Model Number Power Selectable CCT Selectable

HIDFA-11 SS-V-EX39-8CCT-8YP/3SP

| 60W| 3000K
BOW| 4000K
115W| SOOOK

LAMP INSTALLATION

  • Step:1
    Turn off the power before installation. As shown in Figure 1 Remove the old Ballast, Capacitor and lgnitor (if existing) .

  • Step:2
    As shown in Figure 2 Make sure the Alternating Current Wires connect to the socket directly. (Reattach or replace ground lead if one is needed).

  • Step:3
    Select power and CCT of new LED replacement lamp before installation.

  • Step:4
    As shown in Figure 3 Screw the LED lamp into the corresponding socket. Attach retrofit label to luminaire. RAB-HIDFA-115S-V-EX39-8CCT-BYP-3SP-INST-Series-
High-Bay \(5\)

Securely fasten the earth fiy lead cable to the main body structure. If the cable are damaged in anyway please replace. (Do not use existing burnt out cables)The cable if need replacement must be 1.0mm in size and insulated from heat.

Cl 2022 RAB LIGHTIN G Inc.

  • Cra nbury, Ne w Jerse y 08512 USA
  • rablighting.com
  • Visit ou r website for product info

Tech Help line e-mail

  • Call o ur expert s: 888 722-1000        An sw ered promp tly- sales@rablighting.com
  • Free lighting Layouts
  • Answ ered onli ne or by request
  • HIOFAHB-IN-0122

RAB WARRANTY

RAB’s warranty is subject to off terms and conditions found at rablighting.com/warranty.

Documents / Resources

| RAB HIDFA 115S-V-EX39-8CCT-BYP-3SP-INST Series High Bay [pdf] Instructions
HIDFA 115S-V-EX39-8CCT-BYP-3SP-INST Series High Bay, HIDFA, 115S-V-EX39-8CCT- BYP-3SP-INST Series High Bay, Series High Bay, High Bay, Bay
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>