GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter Instruction Manual

June 12, 2024
GOSSEN METRAWATT

Short-form Operating Instructions

METRA HIT 27M/I, H+E CAR

3-349-208-02
5/1.22


Safety Instructions

See Standard Operating Instructions 3-349-207-02 !

Switching on/off

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - a1

Battery Test

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - b1 Change batteries / charge accumulators

Select Measuring Function
Measuring Range Selection

automatic → manual
! MAN ! = fast measurement

V           3 V → 30 VGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d5
30 V → 300 VGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d6
300 V → 600 V GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d6

short

Hz      300 Hz → 3 kHz GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d4

Ω         300 Ω → 3 kΩ GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d4
3 kΩ → 30 kΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d5
30 kΩ → 300 kΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d6
300 kΩ → 3 MΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d4
3 MΩ → 30 MΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d5

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - d3

mΩ        30 mΩ → 300 mΩ
300 mΩ → 3 Ω
3 Ω → 30 Ω

mΩ@1A        3 mΩ → 30 mΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d5
30 mΩ → 300 mΩGOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
d6

manual → automatic

        long (1 s)    or

Measuring Inputs

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - e1

  1. Mass Input (Common Terminal)
  2. Sense for 4-wire connection only with mΩ/Ω@1A
  3. V; Ω; °C, MΩ,
    Measuring Input
Storage of Measured Values (DATA-Hold/-Compare)

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - f2

  1. current value
  2. stored value

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - f3

  1. store
  2. activated
  3. reactivated
Zero balancing

V=                                       3 V DC

            short        300 Ω
Ω(2L)                                             3 kΩ

Close Probe Tips

4L:         automatic

mΩ@1A

Voltage Measurement
Frequency Measurement

V=GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter -
h1        GOSSEN METRAWATT 27M-I METRAHIT
Milliohmmeter - h2

Measuring Ranges:

V=: 0,1 mV … 600 V

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - h3

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - h4

Measuring Ranges:

V~: 0,1 mV … 600 V
Hz:
 1 Hz … 3 kHz

max. 600 V (3 kHz) > 1000 V:

Resistance Measurement
Diode Testing
Continuity Testing

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - i1

Measuring Range: 10 mΩ … 30 MΩ

Conducting Direction

Reverse Direction

  Continuity  R < 10 Ω

Milliohm Measurement

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - j1

Measuring Ranges:

30 mΩ/300 mΩ @ 200 mA
3 Ω / 30 Ω @ 20 mA

  1. Measure Thermo voltage
  2. Offset TC
  3. long

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - j3

  1. Measuring Cables: KC27 / KC4
  2. Measuring Current
  3. Voltage Drop

Temperature Measurement

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - k1

  1. Pt100
    Pt1000 (TF220)
    Ni100
    Ni1000

  2. Cable Resistance

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - k2

RTD|

Measuring Range

---|---
Pt 100|

–200,0 … +100,0 °C

+100,0 … +600,0 °C

Pt 1000|

–200,0 … +100,0 °C

+100,0 … +600,0 °C

Ni 100|

–60,0 … +180,0 °C

Ni 1000|

–60,0 … +180,0 °C

Insulation Resistance Measurement [MΩ] (METRA HIT 27I/H+E CAR only)

GOSSEN METRAWATT 27M-I METRAHIT Milliohmmeter - l1

  1. Continuous Meas.
  2. selected Test Voltage
  3. Test voltage applied as long as key is depressed
  4. Measuring Voltage /Residual Voltage

Measuring Range:

Ω: 10 kΩ … 3 GΩ


© Gossen Metrawatt GmbH
Prepared in Germany • Subject to change, errors excepted • PDF version available on the Internet

All trademarks, registered trademarks, logos, product names, and company names are the property of their respective owners.

Gossen Metrawatt GmbH
Südwestpark 15
90449 Nürnberg • Germany
Telefon+49 911 8602-0
Telefax +49 911 8602-669
E-Mail   info@gossenmetrawatt.com
www.gossenmetrawatt.com

References