KICHLER 52698CPZ Malene 14 Light Taper Candle Style Chandelier Instruction Manual
- June 1, 2024
- KICHLER
Table of Contents
KICHLER 52698CPZ Malene 14 Light Taper Candle Style Chandelier
Product Information
- Dimensions: Varies based on a specific model
- Material: Metal, Glass
- Power Source: Electric
- Colour: Varies based on a specific model
Product Usage Instructions
Installation Instructions
- Rotate fixture arms into position as shown in Fig. 1.
- Slip candle sleeves over sockets and push them down into the socket base. Ensure they are fully seated.
- Screw the decorative tube onto the top of the main body securely.
- Screw the threaded pipe into the screw collar loop and lock it in place with a hex nut.
- Attach the mounting strap to the outlet box using strap mounting screws.
- Adjust the position of the canopy and tighten the hex nuts against the mounting strap.
- Connect the chain to the fixture using open chain links.
- Weave fixture wires through chain links and pass through the various components into the outlet box.
Grounding Instructions
Follow the provided grounding instructions based on the type of mounting strap
provided with your fixture (Illustration a or b). Ensure proper grounding for
safety.
Frequently Asked Questions
Q: Can I use different combinations of candle sleeves on the fixture?
A: Yes, you can install a matching set of candle sleeves or mix and match them as desired. Retain any unused candle sleeves for future use.
Q: How do I secure the threaded pipe and mounting strap during installation?
A: Use hex nuts to secure the threaded pipe into the screw collar loop and mounting strap. Ensure they are tightened properly for stability.
Q: What should I do if my fixture is provided with a ground wire?
A: Connect the fixture ground wire to the outlet box ground wire following the provided grounding instructions. Never connect the ground wire to black or white power supply wires.
FIXTURE DIAGRAM
PARTS LIST
- [A] Outlet Box (Not Supplied)
- [B] Strap Mounting Screw (2)
- [C] Mounting Strap
- [D] Hex Nut (3)
- [E] Threaded Pipe
- [F] Canopy
- [G] Screw Collar Loop
- [H] Threaded Ring
- [I] Open Chain Link (2)
- [J] Chain
- [K] Decorative Loop (preinstalled to Decorative Tube)
- [L] Decorative Tube
- [M] Main Body
- [N] Socket
- [O] Candle Sleeve (2 colour sets)
CAUTIONS
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before
starting and during the installation.
WARNING:
This fixture is intended for installation under the National Electrical Code
(NEC) and all local code specifications. If you are not familiar with code
requirements, installation by a certified electrician is recommended. Failure
to adhere to these codes and instructions may result in serious injury and/or
property damage and will void the warranty.
CLEANING:
- Always be certain that the electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
-
Rotate fixture arms into position as shown (Fig. 1).
-
NOTE: This fixture includes two sets of candle sleeves (different colours). Fixture can be installed with a matching set of candle sleeves, or with any combination of the candle sleeves as desired. Retain the remaining candle sleeves for future use.
Carefully slip the candle sleeve[O] over the socket [N]. Carefully push the candle sleeve down into the socket base.
NOTE: Make sure that the bottom edge of the candle sleeve is fully seated against the bottom of the socket base cup.
Repeat for remaining candle sleeves. -
Screw decorative tube[L] onto the threads on top of the main body[M]. Tighten to secure.
-
Screw-threaded pipe[E] into screw collar loop[G] a minimum of 6 mm (1/4”).
-
Lock the screw collar loop into place with a hex nut[D].
-
Run a second hex nut down the threaded pipe almost touching the first hex nut.
-
Screw threaded pipe[E] into mounting strap[C].
NOTE: The mounting strap must be positioned with extruded thread facing into the outlet box[A]. The threaded pipe must protrude out the back of the mounting strap. -
Screw a third hex nut onto the end of the threaded pipe protruding from the back of the mounting strap.
-
Connect the mounting strap to the outlet box using strap mounting screws[B].
-
Unscrew the threaded ring[H] from the screw collar loop. Take canopy[F] and pass over the screw collar loop. Approximately one-half of the screw collar loop exterior threads should be exposed. Adjust the screw collar loop by turning the assembly up or down in the mounting strap. Remove canopy.
-
After the desired position is found, tighten both top and bottom hex nuts up against the bottom and top of the mounting strap.
-
Slip the canopy over the screw collar loop and screw on the threaded ring.
-
Attach one end of chain[J] to the bottom of the screw collar loop using an open chain link[I]. Attach the opposite end of the chain to the decorative loop using an open chain link.
NOTE: Once an open link is attached to a loop, close the open link by placing a piece of cloth over the open link and using a pair of pliers to gently squeeze the link closed. -
Unscrew the threaded ring, and let the canopy and threaded ring slip down.
-
Weave fixture wires through chain links (no more than 3 inches apart), and pass through a threaded ring, canopy, screw collar loop, threaded pipe and into the outlet box.
-
Grounding instructions: (See Illus. a or b).
- a. On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread it into the hole.
- b. On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and a green ground screw, and thread it into the mounting strap.
If the fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with the wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
-
Make wire connections. Reference the chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black
with Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other
than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) is used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|
18. Raise canopy to ceiling and secure canopy in place by tightening threaded ring [H] onto screw collar loop [G].
NOTE: Make sure wires do not get pinched between the mounting strap and
canopy or canopy and ceiling.
- Insert recommended bulbs (Not supplied).
Warranty
For warranty information please visit: kichler.com/warranty.
© 2024 Kichler Lighting LLC. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>