WyreStorm IDB-400-NA In Desk Connectivity with Power Instruction Manual

June 1, 2024
WyreStorm

WyreStorm-logo

WyreStorm IDB-400-NA In Desk Connectivity with Power

WyreStorm-IDB-400-NA-In-Desk-Connectivity-with-Power-
product

Product Information

Specifications

  • Audio and Video Inputs: 1 x Mains outlet (North American Type B), 1 x USB-C, 2 x HDMI, 1 x RJ-45, 2 x USB Type A Charging Ports
  • Video Passthrough (Max): Power
  • Mains Connection:
  • USB Charging:
  • Environmental: Operating Temperature
  • Dimensions and Weight:
    • Length x Width x Height
    • Weight
  • Regulatory: Safety and Emission

Product Usage Instructions

Mounting Instructions
Read through the mounting instructions before installing to ensure proper operation and avoid damaging the equipment. Table depth must be between 12-60mm for installation.

Opening Instructions
To open the product, press the button on the top of the flap or lift up the flap. To close, gently push the flap downwards until it clicks.

Mains Wiring
The MS models use a Wieland EPN 1114 mains connector. Ensure you have the compatible power supply cable with an EPN 1115 connector and the proper plug type based on the country of installation.

Wiring and Connections
All wiring should be run and terminated before making connections to the desk plate. Use pre-terminated cables to ensure accurate connections without interfering with performance.

FAQ

  • Q: What depth should the table be for installation?
    A: The table depth must be between 12-60mm for installation.

  • Q: How do I open and close the product?
    A: To open, press the button on the top of the flap or lift up the flap. To close, gently push the flap downwards until it clicks.

  • Q: What type of mains connector is used in the MS models?
    A: The MS models use a Wieland EPN 1114 mains connector. Ensure you have the compatible power supply cable with an EPN 1115  connector and the proper plug type based on the country of installation.

Flip Up In-Desk Connectivity with 1x Mains (North America/Multi-Standard), USB Charging, 2x HDMI, USB-C & RJ-45 Passthrough
IDB-400-NA | IDB-400-MS

Quickstart Guide
WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features before beginning the installation process.

IMPORTANT! Installation Requirements

  • Read through the Wiring and Connections section for important wiring guidelines before creating or choosing premade cables.
  • Visit the product page to download the latest firmware, document version, additional documentation, and configuration tools.

In the Box
1x IDB-400-NA or IDB-400-MS

Mounting Instructions

WyreStorm recommends that you read through this section in its entirety before installing to ensure proper operation and to avoid damaging the equipment. We have provided you with a cutting template on the last page of this document to make it easier for you to ensure proper installation.
Please Note: There needs to be two holes made for installation to account for cabling and are both marked on the template provided.

  • Once the hole has been cut to size, the product should simply slot into place. Make sure all cables are passed throught the hole first.
  • When the In-desk plate is situated in the hole, you can tighten the product in place by screwing the two Philips head screws at the bottom of the product.

Opening Instructions

Open the product by simply pressing the button on the top of the flap. You can also open by just lifting up the flap. To close the unit, gently push the flap downwards until it clicks.

WyreStorm-IDB-400-NA-In-Desk-Connectivity-with-Power-
\(4\)

Mains Wiring
The MS models of the IDB products use a Wieland EPN 1114 mains connector. This connector requires a compatible power supply cable with an EPN 1115 connector and the proper plug type based on country of installation. The WyreStorm IDB- PWR-UK or IDB-PWR-SCH can be purchased separately and used with the IDB-MS products which are compatible with most European countries.

WyreStorm Connector   3rd Party Device
Pin 1 L (Live) —> To —>
Pin 2 G (Ground) —> To —>
Pin 3 N (Neutral) —> To —>

WyreStorm-IDB-400-NA-In-Desk-Connectivity-with-Power-
\(6\)

Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the deskplate. Read through this section in its entirety before running or terminating any wires to ensure proper operation and to avoid damaging the equipment.

IMPORTANT! Wiring Guidelines

  • WyreStorm recommends using pre-terminated cables due to the complexity of these connector types. Using pre-terminated cables will ensure that these connections are accurate and will not interfere with the performance of the product.
  • This product contains a USB-C connection that can be used as an audio/video input. When using this connection verify that the USB-C cable used supports audio/video functionality as not all USB-C cables support this requirement.

Troubleshooting

No or Poor Quality Picture (snow or noisy image)

  • Verify that all HDMI connections are not loose and are functioning properly.
  • Verify that USB-C connections are not loose and are functioning properly.
  • If transmitting 4K, verify that the HDMI cables used are 4K rated.

Troubleshooting Tips
WyreStorm recommends using a cable tester or connecting the cable to other devices to verify functionality.

Specification

WyreStorm-IDB-400-NA-In-Desk-Connectivity-with-
Power-01

Note: WyreStorm reserves the right to change product specification, appearance or dimensions of this product at any time without prior notice.

Warranty Information

WyreStorm Technologies LLC warrants that its products to be free from defects in material and workmanship under normal use for a period of five (5) years from the date of purchase. Refer to the Product Warranty page on wyrestorm.com for more details on our limited product warranty.WyreStorm-IDB-400-NA-In-Desk-Connectivity-with-Power-
\(7\)

Copyright © 2021 WyreStorm Technologies | wyrestorm.com IDB-400-xx Quickstart Guide | 210901
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973) support@wyrestorm.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WyreStorm User Manuals

Related Manuals