AMERICAN LIGHTING NFPROL-RE-98 Linear 98 Long Strip Light Instruction Manual

June 1, 2024
American Lighting

AMERICAN-LIGHTING-logo

AMERICAN LIGHTING NFPROL-RE-98 Linear 98 Long Strip Light

Specifications

  • Electrical Rating: 120V AC (NV5 & NV7) and 120-277V AC (NV5-0/10V & NV70/10V), 60Hz
  • Input Voltage for Battery Back-Up : 100-277V AC, 50-60Hz
  • Output Power of Battery Back-Up : Up to 20W

Product Usage Instructions

Installation:

  1. Ensure power is disconnected at the source and wall switches are off.
  2. Affix the mounting plate to the junction box using provided screws.
  3. Connect supply wires to fixture wires, ensuring polarity match.

Battery Back-Up Installation:

  1. Disconnect power and wall switches.
  2. Connect supply wires to battery back-up, matching polarity.
  3. Affix the battery back-up to the junction box using screws.
  4. Connect supply wires from battery back-up to fixture wires, ensuring polarity match.
  5. Complete setup by pushing the fixture into the center and securing clips.
  6. For wet locations, seal edges with waterproof silicone.

Photometric Distribution:
Show intensity in candelas for NV5 and NV7 series.

FAQ

  • What is the electrical rating of the product?
    The product has an electrical rating of 120V AC (NV5 & NV7) and 120-277V AC (NV5-0/10V & NV70/10V), 60Hz.

  • How should I install the product for wet locations?
    To install in wet locations, seal the edges of the fixture and battery back-up with waterproof silicone.

WARNING
These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).

WARNING
The electrical rating of this product is 120V AC (NV5 & NV7) and 120-277V AC (NV5-0/10V & NV7-0/10V), 60Hz. The installer must determine whether the power supply is appropriate at the luminaire prior to installation. To avoid possible electric shock, be sure that power source is turned off at fuse box and/or circuit breaker prior to attempting installation or servicing of the fixture.

WARNING
Use with a 4” octagonal or round junction box with a minimum depth of 1-1/4” . Required distance between mounting holes: 3-1/2”.
Do not attempt to alter for other sizes or purposes.

SAFETY INFORMATION

  • Read all instructions before beginning; Save these instructions for future use.
  • To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product.
  • LED Disc light installation requires knowledge of recessed lighting luminaires and their electrical systems. If not qualified or uncertain, do not attempt installation: contact a qualified electrician.
  • Supply conductors (power wiring) connecting the fixture must be rated for a minimum of 90°C.
  • Do not make or alter any open holes in wiring enclosures, nor in any electrical components during kit installation.
  • Do not alter, relocate, or remove wiring, lamp holders, power supply, or any other electrical component.
  • This fixture is suitable for use in dry, damp, or wet locations.
  • Do not use these products in luminaires located where elevated ambient temperatures exist.
  • To avoid electrical shock, do not turn on fixture with missing or damaged lens.
  • There are no serviceable parts inside the fixture or LED module.
  • Use only a mild soap and water with soft cloth to clean the fixture. Harsh chemicals will damage the finish. Do not wipe the fixture with a rough cloth that may scratch the finish or lens.
  • This fixture is suitable for use in dimming circuits: NV5-30-WH & NV7-30-WH: TRIAC/CL/ELV (FOR 120V ONLY) NV5-0/10V-30-WH & NV7-0/10V-30-WH: 0-10V
  • When using a battery backup accessory, the fixture is not rated for dimming circuits without UL924 shunt relay and the dimming wires should be capped and not used.

INSTALLATION

  1. Ensure power is disconnected at the source and any wall switches are in the “off” position.
  2. Affix the mounting plate directly to junction box using the mounting screws provided. See Figure 1.
  3. Connect supply wires to fixture wires, ensuring to match polarity. For NV5-30-WH & NV7-30-WH (FOR 120V ONLY): Ground/Green toGround, Common/White to White, Hot/Black to Black, and insulateconnections with included wire nuts. For NV5-0/10V-30-WH & NV7-0/10V-30-WH: Ground/Green to Ground, Neutral/White to White, Hot/Black to Black, then 0-10V wires Purple/+ to + and Grey/- to -, and insulate connections with included wire nuts. See Figure 2.
  4. Complete the installation by pushing the fixture into the mounting plate so the clips fully seat into the center of the plate. See Figure 2.
  5. For wet location applications, seal the edge of the fixture where it meets the ceiling surface with waterproof silicone (Not provided).
  6. For use with battery back-up (NV7-BB-WH sold separately),

AMERICAN-LIGHTING-NFPROL-RE-98-Linear-98-Long-Strip-Light-
fig-2

BATTERY BACK-UP INSTALLATION (Figures 3-5)

This battery back-up (NV7-BB-WH) is rated for an input voltage of 100-277V AC, 50-60Hz and produces an output power of up to 20W. It is intended for use with NV7-30-WH or NV7-0/10V-30-WH only.

  1. Ensure power is disconnected at the source and any wall switches are in the “off” position.
  2. Connect supply wires to battery back-up, ensuring to match polarity (Ground/Green to Ground, Common/White to White, Hot/Black to Black) and insulate connections with included wire nuts.
  3. Affix the battery back-up directly to the junction box via two screw holes on the back of the battery back-up. Connect supply wires from battery back-up to fixture wires, ensuring to match polarity
    • Un-switched Load: (Ground/Green to Ground, Neutral/White to White, Hot/Black to Black and Brown) and insulate connections with included wire nuts.
    • Switched Load: (Ground/Green to Ground, Neutral/White to White, Unswitched Hot/Black to Black and Switched Hot/Black to Brown) and insulate connections with included wire nuts.
  4. Complete the installation by pushing the fixture into the battery backup so the clips fully seat into the center. Ensure all 4 clips are oriented so they grip onto the edge of the battery back-up.
  5. For wet location applications, seal the edge of the fixture where it meets the ceiling and where the battery back-up meets the fixture with surface with waterproof silicone (Not provided).
  6. See Figure 5 for battery back-up operation.

AMERICAN-LIGHTING-NFPROL-RE-98-Linear-98-Long-Strip-Light-
fig-3

PHOTOMETRIC DISTRIBUTION SHOWING INTENSITY (Candelas)

AMERICAN-LIGHTING-NFPROL-RE-98-Linear-98-Long-Strip-Light-
fig-4

FCC Compliance Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC WARNING
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

5-YEAR LIMITED PRODUCT WARRANTY

This product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronics, defective parts of the fixture housing, lens, wiring, switching or lamp sockets; excluding the lamp) or replaced, at the discretion of American Lighting, Inc claims for defective products must be submitted to the retail location from which the product was purchased withing the warranty period. Upon submission of proper return claim documentation and product to American Lighting, Inc by the retailer, American Lighting, Inc reserves the right to inspect the product for misuse or abuse. Claims for indirect or consequential damages or for product that, in American Lighting, Inc’s opinion has bee misused, will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc shall have no liability whatsoever in any event for payment of incidental or consequential damages, including, without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or altered in any way. This warranty applied only to product that has been properly installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situation where components have been altered in any way. This warranty: (1) excludes expendable parts including but not limited to light bulbs, batteries; (2) carries a 2-year finish warranty protecting finish against tarnishing, flaking, and discolorations; (3) shall be void if this lighting fixture is not installed in the U.S.A.; and (4) does not cover any losses, labor, injuries to persons/property or costs. This warranty does give you specific legal rights and you may have other rights, which vary from state to state, Be careful, it is recommended that installation be done by a qualified professional; the purchaser has sole responsibility for proper installation in compliance with all state and local code requirements. Seller’s employees are not qualified to advise you on the use of this Merchandise. Any oral representation(s) made will not be binding on seller or its employees. The rights under this limited warranty are to the original purchaser of the Merchandise and may not be transferred to any subsequent owner. This limited warranty is in lieu of all warranties, expressed or implied including warranties or merchantability and fitness for a particular purpose. Seller shall not be liable for any special, incidental, or consequential damages. The sold exclusive remedy against the seller will be for the replacement of any defects as provided herein, as long as the seller is willing or able to replace this product or is willing to refund the purchase price as provided above.
For questions/comments, technical assistance, or repair parts – Please call toll free at 1-800-285-8051 (M-F 8am- 5pm), CST)

ABOUT COMPANY

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

American Lighting User Manuals