BEGA 85108 Compact Downlight Instruction Manual

June 1, 2024
BEGA

BEGA 85108 Compact Downlight

Dimension

Compact downlight with minimal diffuse light percentage

Dimension

Instructions for use

Application

Compact floodlight with mounting box for permanent installations on a wall, under a ceiling or on a pillar.

BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to a minimised diffuse light percentage and highly efficient glare suppression.

Product description

Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Matt safety glass
Internal louvres and polymer lens
BEGA Ultradark Optics®
Louvres and interior surface of anti-glare ring
with maximum light-absorbing ultra-black nano-coating
Rotation range of floodlight 350°
Swivel range -15°/+90°
Mounting box with 2 fixing holes
ø 4.8mm · 67mm spacing
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm, max. 5G1.5@
Connecting terminal 2.5@ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK08
Protection against mechanical impacts < 5 joule
– Conformity mark
Wind catching area: 0.024 m² Weight: 2.0 kg
This product contains light sources of energy efficiency class(es) E, F

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Please note:
Contact with the inner surface of the luminaire reflector should be avoided in order to permanently protect the special stray lightminimising properties of the nano-coating.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and remove mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).
For digital control please use the 2-pole plug connector DA, DA.
In case this connector is not used the luminaire will be operated at full light output.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.

Installation

Place floodlight unit onto the mounting plate as displayed in the sketch, align and screw together firmly.

Adjustment of beam direction:
Undo joint screw (hexagon socket head
wrench size 5 mm) and set the desired beam
direction.
Tighten the joint screw.
Torque = 7Nm.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Lamp
Module connected wattage 18.3 W
Luminaire connected wattage 20.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C

85 108K3
Module designation LED-1254/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 2190 lm
Luminaire luminous flux 1098 lm
Luminaire luminous efficiency 53,6 lm/W

85 108K4
Module designation LED- 1254/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 2375 lm
Luminaire luminous flux 1190 lm
Luminaire luminous efficiency 58 lm/W

Lighting technology
Symmetrically focused broad spread light distribution with minimal diffuse light percentage.
Half beam angle 56°

Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified person using commercially available tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2) in the trim ring.
Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
Please note:
Contact with the inner surfaces of the louvres and luminaire reflector should be avoided in order to permanently protect the special stray light-minimising properties of the nano-coating.
Grasp the louvres from the outside and lift them out. Loosen the three mounting screws (Torx drive T20) and lift the lens holder (with the loosely inserted lenses) upward horizontally out of the housing.
Replace LED module.
Please follow the installation instructions for the LED module.
Install in reverse order.
When installing the lens holder, make sure that the LED connecting cable is not pinched.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

71280 Shield
71 285 Cylindrical shield

For the accessories a separate instructions for use can be provided upon request.

Spares
Trim ring graphite with glass 25 000 234
Trim ring silver with glass 25 000 235
LED power supply unit DEV-0485/900i
LED module 3000 K LED-1254/930
LED module 4000 K LED-1254/940
Gasket mounting box 83 001 839
Gasket housing 83 002 022
Gasket Abschlussring 83 002 222

Customer Support

4/4 BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals