Current Element L2000 Horticulture LED Lighting System Installation Guide

June 10, 2024
current

Current Element L2000 Horticulture LED Lighting System

Current-Element-L2000-Horticulture-LED-Lighting-System-
product

The Horticulture LED Lighting System is a state-of-the-art grow light system designed for indoor horticulture. It provides the ideal spectrum of light for plants to thrive and grow. The system is easy to install and comes with all the necessary components.

Components

  • Light Fixture
  • AC Leader Cable (4ft)
  • AC Field Installable Connector (UL and CE certified)
  • Dimming Cable (3ft)
  • Suspension Cables (optional)
  • Mounting Kit (18″ or 60″)

Luminaire Specifications

Order Code Weight System Input Current [A] @ 277/347/480VAC
GEHE-M3PKT-5WN2-xx 14.5 kg (32 lbs) 3.6/2.9/2.2
GEHE-M3PKR-5WN2-xx 14.5 kg (32 lbs) 3.8/3.0/2.2
GEHE-T3PKF-5WN2-xx 14.5 kg (32 lbs) 3.4/2.7/2.0
GEHE-M3BRI-5WN2-xx 14.5 kg (32 lbs) 3.5/2.8/2.1

Interconnection Cable Specifications

Description Detailed Description
AC Leader Cable (4ft) UL certified
AC Field Installable Connector UL and CE certified (Wieland P.N.

96.031.4155.7)
Dimming Cable (3ft)| UL and CE certified

Mounting Accessories Specifications

Description Detailed Description Weight
18″ Cable Universal Mounting Kit 0.1 kg (0.2 lbs)
60″ Cable Universal Mounting Kit 0.1 kg (0.2 lbs)

Product Usage Instructions

  1. Before installation, verify that all DC connectors are installed and fully engaged.
  2. Do not make any connections while the luminaire is energized.
  3. Do not make or break electrical connections while power is applied.
  4. Refer to the latest European install guides and safety information for proper installation and usage instructions.

For the latest European install guides and safety information: https://www.gecurrent.com/eu-en/indoor-lighting/horticulture-led-grow- lights

For the UL installation guide and safety information

BEFORE YOU BEGIN

  • Read these instructions completely and carefully.
  • For Commercial or Industrial use only
  • DO NOT MAKE OR BREAK ELECTRICAL CONNECTIONS WHILE POWER IS APPLIED.

WARNING: RISK OF ELECTRIC SHOCK

  • Turn power off before installation, inspection, cleaning or removal. And follow appropriate lock out/tag out safety procedure.
  • Properly ground electrical enclosure.
  • Follow all National Electric Codes (NEC) and local codes.
  • This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • The installation and associated structures are subject to approval by the authority having jurisdiction.
  • Use only with components identified in this document.
  • Suitable for dry, damp, and wet locations; Do not immerse any component.
  • Wear suitable Personal Protective Equipment (PPE) during installation/maintenance. Highly recommend safety glasses, helmet and leather glove for luminaire mounting.
  • Luminaire design for Greenhouse only.

RISK OF FIRE

  • Minimum 24 inch distance from light module & driver to any combustible material.
  • The light module shall be installed lens down with a minimum 60 inch distance to the floor.
  • All cables including connectors shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure; located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure.
  • Cables shall be routed so that they are not subject to strain and are protected from physical damage; visible over their entire length; and used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
  • For safe operation, and to maximize the longevity of the luminaire; ensure that the light module and driver are clean and free of dirt, dust, oil, or any other debris. Do not apply any kind of film on the lens or otherwise cover the driver or light engine in any way.

Suitable for operation in an ambient temperature between 14°F (-10°C) and 95°F (35°C).

  • A mechanical ventilation or cooling system is required to maintain the temperature within the growing space below 95°F (35°C) when the light module is in operation.

Components

Current-Element-L2000-Horticulture-LED-Lighting-System-
FIG-3

  1. Arize Element® L2000
  2. AC input leader cable
  3. Light module brackets
  4. 1-5/8″ (41mm) Wire Hangers (included); or
  5. Suspension cables (optional)

Luminaire Specifications

**Order Code| ****Weight| System Input Current [A] @ 277/347/480VAC**
---|---|---
GEHE-M3PKT-5WN2-xx| 14.5 kg (32 lbs)| 3.6/2.9/2.2
GEHE-M3PKR-5WN2-xx| 14.5 kg (32 lbs)| 3.8/3.0/2.2
GEHE-T3PKF-5WN2-xx| 14.5 kg (32 lbs)| 3.4/2.7/2.0
GEHE-M3BRI-5WN2-xx| 14.5 kg (32 lbs)| 3.5/2.8/2.1

Interconnection Cable Specifications

Description Detailed Description
GECA60C16-OL04B AC Leader Cable, 4ft, UL
GECA60FNA-NL00B AC Field Installable Connector, UL and CE (Wieland P.N.

96.031.4155.7)
GECA30H20-OO03B| Dimming cable, 3ft (914mm), UL and CE

Mounting Accessories Specifications

Description Detailed Description Weight
GEMB-CBH1 18″ (457mm) cable universal mounting kit 0.1 kg (0.2 lbs)
GEMB-CBH2 60″ (1524mm) cable universal mounting kit 0.1 kg (0.2 lbs)

CAUTION

  • Installation instructions and specifications for accessories can be found in the accessory package.

Sample Installation Diagram

Current-Element-L2000-Horticulture-LED-
Lighting-System-FIG-4

BEFORE INSTALLATION

  • Verify that all DC connectors are installed and fully engaged. (Arrow on the connector locking ring should be facing up.)
  • DO NOT MAKE ANY CONNECTIONS WHILE THE LUMINAIRE IS ENERGIZED.
Installation of Luminaire

Wire Hangers

Unistrut 1-5/8″ (41mm)
Use standard hanger 1-5/8″ (41mm)

  1. Place wire hangers over Unistrut.
  2. Attach light module brackets to the luminaire.
  3. Hang luminaire.Current-Element-L2000-Horticulture-LED-Lighting-System-FIG-9
Universal Cables

Other Structural Members

  • Use 18″ (0.5m) or 60″ (1.5m) universal cable
  1. Wrap the loop end of the cable over the structural member. Insert hook through the loop end.
  2. Attach hooks to light module brackets. Ensure the hook gate is closed.Current-Element-L2000-Horticulture-LED-Lighting-System-FIG-11

Electrical Connections

WARNING: RISK OF ELECTRIC SHOCK
Turn the power OFF before inspection, installation, or removal.

Driver Connections

Connect the AC Input

Connect the Driver InputCurrent-Element-L2000-Horticulture-LED-Lighting-
System-FIG-16

  1. Align keying features on driver with connector on the selected leader cable.
  2. Push connectors together until a click is heard.
  3. Recommended: secure AC input leader cable.Current-Element-L2000-Horticulture-LED-Lighting-System-FIG-17

Using Custom AC Inputs

If you choose to use your own custom AC input connection, use a Wieland RST20i3 green connector (96.031.4055.7 OR 96.031.4155.7 OR 96.031.0055.7 OR 96.031.1055.7) and plug into the male AC connector of the driver.

Connecting Driver to AC Line

Connect the black wire to Line 1 and white wires to Neutral or Line 2 of the incoming AC line. Care should be taken to properly balance 3 phase loads. Connect the green wire to the incoming ground conductor.

Connecting Wired Dimming (Optional)

WARNING: RISK OF ELECTRIC SHOCK

  • Turn power off before installation, inspection, cleaning or removal. And follow appropriate lock out/tag out safety procedure.
  • This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • NOTE: Arize L1000 dimming allows user to adjust the light output from 0%/10-100%. When set to 0%, the system will enter standby mode, consuming 0.5-1.5W and LEDs may remain very faintly lit. If 0 light is preferred, switch off the unit via the mains (AC line).Current-Element-L2000-Horticulture-LED-Lighting-System-FIG-20
  1. Remove cap from dimming connector
  2. Plug dimming cable: align keying features and push connectors together until lock ring has snapped into place and a click is heard. To remove dimming cable, turn locking ring 1/8 of a turn counter-clockwise and separate connectors.
  3. Connect the appropriate wiring to Dim + (0-10V) and Dim – (0-10V) from driver. Insulate the black wire. Follow dimming switch instructions for rest of connection.
    The black/white wire is a 12V auxiliary output that can support up to 250mA of current.

RISK GROUP 1 – NOTICE

  • UV emitted from this product. Minimize exposure to eyes or skin. Use appropriate shielding.
  • These photobiological safety markings are based on testing of the light output characteristic of a single horticultural luminaire.
  • Increased exposure risk to facility personnel may be present depending upon the number of horticultural luminaires and their placement and/or positioning within the plant growth facility.
  • It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on, are aware of these risks and that appropriate safeguards are in place.

Save These Instructions

FCC

  • Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
  • This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.
  • NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  • This Class [A] RFLD complies with the Canadian standard ICES-005.
  • Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.
  • For the latest install guides for your product go to: https://www.gecurrent.com/horticulture
  • Visitwww.LED.com
  • Call us today! 1-888-694-3533 Email us:[email protected]
  • orgecurrent.com/arize
  • © 2022 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

current User Manuals

Related Manuals