BEGA 84855 Powerful Projector Instruction Manual

June 1, 2024
BEGA

BEGA 84855 Powerful Projector

Specifications:

  • Power Consumption: 38.4 W
  • Lamp Module Connected Wattage: 38.4 W
  • Luminaire Connected Wattage: 42.5 W
  • Rated Temperature: 25-35°C
  • Ambient Temperature: 25-35°C
  • Colour Temperature: LED-1020/830 (3000 K) / LED-1020/840 (4000 K)
  • Colour Rendering Index (CRI): > 80
  • Luminous Flux: 6635 lm – 7005 lm
  • Luminous Efficiency: 102.6 lm/W – 108.3 lm/W

Product Usage Instructions

Safety:

The installation and operation of this luminaire must comply with national safety regulations. The manufacturer is not liable for damage due to improper use or installation. Any modifications should be performed by qualified individuals.

Overvoltage Protection:

The luminaire’s electronic components are protected against overvoltage as per DIN EN 61547. For additional protection against transients, etc., consider separate overvoltage protection components available on the manufacturer’s website.

Adjustment of Beam Direction:

To adjust the beam direction, undo the joint screw using a hexagon socket head wrench size 5 mm. Set the desired beam direction and then tighten the joint screw with a torque of 7 Nm.

Maintenance:

Do not remove the desiccant bag from the luminaire housing as it helps remove residual moisture. The connecting cable should be regularly checked for external damage and only replaced by a qualified electrician.

Accessories:

Various plug types are available for connecting cables, including Plug type F/E (Germany/Europe), Plug type G (Great Britain), Plug type J (Switzerland/Liechtenstein), Plug type L (Italy/Greece), and Plug type K (Denmark/Greenland).

Note:

For detailed instructions on using the accessories, request a separate instructions manual.

Frequently Asked Questions

  • Q: Can I use this luminaire outdoors?
    • A: This luminaire is suitable for indoor use only.
  • Q: How do I clean the luminaire?
    • A: Use a soft, dry cloth to gently wipe the luminaire. Avoid using harsh chemicals or abrasive materials.\

Dimension

BEGA-84855-Powerful-Projector-fig-1

Instructions for use

Application

Performance floodlight BEGA UniLink® with earth spike and 5 m connecting cable with plug connector. A separate mains plug must be ordered in order to connect the floodlight to the mains. The various country-specific mains plugs with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product description

  • Luminaire made of aluminium alloy,
  • aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite
  • Earth spikes made of glass fibre reinforced synthetic material
  • Safety glass with optical structure
  • Reflector surface made of pure aluminium
  • Swivel range -90°/+90°, 5 m mains supply cable
  • X05RN-F FEP 2 × 1@ + 1G2,5@ with plug-in connector
  • BEGA Ultimate Driver®
  • Complies with flicker requirements in
  • accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V∼ 50-60 Hz
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect
  • temperature-sensitive components without
  • switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength: IK07
  • Protection against mechanical
  • impacts < 2 joule
  • Conformity mark
  • Weight: 3.3 kg
  • This product contains light sources of energy efficiency class C

Safety

The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Total load

When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires. Power consumption of 84 855: 0,2 A

Lamp

  • Module connected wattage 38.4 W
  • Luminaire connected wattage 42.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

84 855 K3

  • Module designation LED-1020/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6635 lm
  • Luminaire luminous flux 4361 lm
  • Luminaire luminous efficiency 102,6 lm / W

84 855 K4

  • Module designation LED-1020/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 7005 lm
  • Luminaire luminous flux 4604 lm
  • Luminaire luminous efficiency 108,3 lm / W

Lighting technology

Wide beam light distribution Half beam angle 44°

Caution:

The BEGA UniLink® plug connectors may only be connected and disconnected in a voltagefree state.

Installation

Press the luminaire with earth spike vertically into the soil until stability is achieved. If necessary, compact soil around the earth spike. Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable. To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.

  • Adjustment of beam direction: Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction. Tighten the joint screw.
    • Torque = 7 Nm.

Please note:

Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners

Maintenance

The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced. Close the luminaire.
  • Tighten grub screws (wrench size 3 mm) evenly.
  • Torque = 2.5 Nm.

Accessories

0.5 m connecting cable with country-specific mains plugs

  • 71 180 Plug type F / E: system common in Germany and Europe
  • 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
  • 71 182 Plug type J: system common in Switzerland and Liechtenstein
  • 71 183 Plug type L: system common in Italy and Greece
  • 71 184 Plug type K: system common in

Denmark and Greenland

  • 71 186 BEGA UniLink® Extension cable 5 m
  • 71 187 BEGA UniLink® Extension cable 10 m
  • 71 188 BEGA UniLink® Extension cable 20 m
  • 71 247 Connecting cable 5 m with free line ends
  • 71 256 Connecting cable 0.5 m with free line ends
  • 71 189 BEGA UniLink® Five-way distribution box

For the accessories a separate instructions for use can be provided upon request.

Spares

  • Spare glass with frame 25 000 145
  • LED power supply unit DEV-0131/850
  • LED module 3000 K LED-1020/830
  • LED module 4000 K LED-1020/840
  • Reflector 76 001 459 .A
  • Gasket 83 001 981

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals