Instructions for use

Application

Free radiating wall luminaire · indoor luminaire with hand-blown three-ply opal glass for a soft and uniform light distribution.
The elongated design of this wall luminaire particulary provides suitability for installation on pillars, columns and for the front surface of walls, as well as for recesses or profiles.
The luminaire may be installed horizontally or vertically.

Product description

Metal luminaire housing,
finish Colour velvet copper
Hand-blown opal glass
The electrical equipment can be hinged
2 mounting holes ø 6 mm
Distance apart 300 mm
Jointing sleeve with
cable entry for mains supply cable up to
ø 14 mm, max. 5 x 1.5@
Connecting terminals 2.5@
Earth conductor terminal
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-276 V
During DC operation the LED power
is reduced to 15 %
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK03
Protection against mechanical
impacts < 0.35 joule

FIG 3.JPG

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.

If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

FIG 4 Overvoltage protection.JPG

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

Undo hexagon socket (wrench size 5) in the locking cap and remove it.

The opal glass can now be hinged together with the electrical equipment to the front.

Remove opal glass.
Note position of application of the luminaire »arrow down«.

Drill mounting holes into the mounting surface
– spacing 300 mm and turn in enclosed or suitable fixing screws.

For the electrical connection undo the screw connection at the line connector and remove terminal block.

Make earth conductor connection and electrical connection.

Make connection of the phase with the L marked, the neutral wire at the N marked and earth conductor at the PE marked connecting terminal.

For digital actuation please use the two connecting terminals DA. If these terminals are not assigned, the luminaire will work with full light output.

Bolt together both screw cable glands firmly.
Hook luminaire into the fixing screws and tighten.

Slide opal glass over the lamp and fasten with the locking cap.
Make sure that the gaskets are positioned correctly.

FIG 5.JPG

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.

Spares

FIG 6 Spares.JPG

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com