BEGA 24 791 Recessed Ceiling Spotlight Instruction Manual

June 1, 2024
BEGA

BEGA 24 791 Recessed Ceiling Spotlight

BEGA-24-791-Recessed-Ceiling-Spotlight-PRODUCT

Product Information

Specifications

  • Material: Cast aluminum, aluminum, stainless steel
  • Required installation depth: 105 mm
  • External power supply: 220-240 V x 0/50-60 Hz
  • Protection class: IP 65
  • Impact strength: IK07
  • Safety class: II 2
  • Energy efficiency class: D

Product Usage Instructions

Installation

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage due to improper use or installation.

Components

The luminaire is made of cast aluminum, aluminum, and stainless steel. Fixing is achieved with 2 fastening springs. It includes an external power supply unit housing with an electrical connection compartment made of glass fiber- reinforced synthetic material.

Safety Information

Ensure the protection of electronic components by using bounce-free switching contacts like an electronic relay.
Overvoltage protection is essential, and additional protection against transients is recommended.

LED Handling

LEDs are high-quality electronic components. Avoid direct contact with the light output opening during installation or relamping. Cover the recessed opening with the stop.

FAQ

Q: What should I do if modifications are needed on the luminaire?

A: Any modifications should be done by a qualified person. The responsible individual for modifications will be considered the manufacturer for liability purposes.

Q: How can I achieve optimal protection for electronic components?

A: Use bounce-free switching contacts like an electronic relay for ideal protection. Additional overvoltage protection components can be found on the manufacturer’s website.

Dimension

BEGA-24-791-Recessed-Ceiling-Spotlight-FIG-1

Instructions for use

Application

  • Recessed ceiling spotlight with small dimensions and high light output.
  • With an external power supply unit for installation into concrete ceilings or suspended ceilings both indoors and out.

Product Description

  • Luminaire made of cast aluminum, aluminum, and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or white
  • Polymer lens
  • Recessed opening ø 68 mm
  • Required installation depth 105 mm
  • Fixing is achieved by using 2 fastening springs
  • External power supply unit housing with electrical connection compartment made of glass fiber-reinforced synthetic material  (polyamide)
  • Complies with flicker requirements by IEEE 1789,  DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz 2 screw cable glands with strain relief for through-wiring of the mains supply cable from ø 4–10 mm, max. 3 × 1.5@ 1 screw cable gland closed at the factory with a dummy plug 0,25 m connection cable between the luminaire and the power supply unit
  • Safety class II
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • Conformity mark
  • Weight: 0.4 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

  • LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Cover the recessed opening with the stop ring of the luminaire housing.
  • The luminaire housing is then fixed in the recessed opening via two springs.

Installation in concrete ceilings:

  • To accommodate the luminaire and the external power supply unit we recommend using the installation housing 13 618.

Installation in suspended ceilings:

  • A recessed opening of ø 68 mm with a minimum depth of 105 mm is required.
  • The external power supply unit requires a minimum of 105 mm clearance above the ceiling.
  • Undo the screw and lift the cover off the connection housing.
  • Pass the power connecting cable through the screw cable gland and make the electrical connection. If a protective earth conductor is included in the connecting cable, it must be connected to the terminal marked “E”.
  • The factory-installed dummy plug must be replaced with the enclosed sealing ring for through-wiring. Tighten the screw cable glands securely. Fit the cover on the connection housing.
  • Slide the external power supply unit into the ceiling opening.
  • Press the luminaire housing against the spring pressure into the installation opening.

Lamp

  • Module connected wattage 5 W
  • Luminaire connected wattage 6.3 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C
  • When installed in heat-insulating material ta max = 35 °C

24 791 K3

  • Module designation LED -1389/830
  • Color temperature 3000 K
  • Color rendering index CRI > 80
  • Module luminous flux 860 lm
  • Luminaire luminous flux 640 lm
  • Luminaire luminous efficiency 101,6 lm / W

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 60°

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Close the luminaire.

Cleaning · Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Accessories

  • 13 618 Installation housing
  • Separate instructions for use can be provided upon request.

Spares

  • LED power supply unit DEV-0216/140
  • LED module 3000 K LED-1389/830
  • Gasket 83 002 220
  • BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · [email protected] · www.bega.com

Documents / Resources

| BEGA 24 791 Recessed Ceiling Spotlight [pdf] Instruction Manual
24 791 Recessed Ceiling Spotlight, 24 791, Recessed Ceiling Spotlight, Ceiling Spotlight
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals