BEGA 85 175 Performance Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 85 175 Performance Floodlight Instruction Manual
Instructions for use
Application
Performance floodlight BEGA UniLink® with earth spike and 5m connecting cable
with plug connector.
A separate mains plug must be ordered in order to connect the floodlight to
the mains.
The various country-specific mains plugs with 0.5m connecting cable, as well
as extension cables and five-way distribution boxes are available as
accessories.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite
Earth spike made of glass fibre reinforced synthetic material
Clear safety glass
Silicone gasket
Reflector surface made of pure aluminium
Optical silicone lens · BEGA Hybrid Optics®
Swivel range -80°/+90°
5m mains supply cable
X05RN-F FEP 2×1@ + 1G2,5@ with plug-in connector
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V ⁓ 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Conformity mark
Weight: 2.4 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71320.
Total load
When configuring your lighting system, please ensure that the maximum power
consumption of 6A is not exceeded. Information on power consumption can be
found in the instructions for use and data sheets for all BEGA UniLink®
luminaires.
Power consumption of 85 175: 0,12 A
Caution:
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage free state.
Lamp
Module connected wattage 24.1 W
Luminaire connected wattage 27 W
Rated temperature ta=25 °C
Ambient temperature ta max=30 °C
85 175K3
Module designation LED-0800/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3350 lm
Luminaire luminous flux 2472 lm
Luminaire luminous efficiency 91,6 lm/W
85 175K4
Module designation LED-0800/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 3400 lm
Luminaire luminous flux 2509 lm
Luminaire luminous efficiency 92,9 lm/W
Lighting technology
Symmetrical wide beam light distribution Half beam angle 45°
For special lighting applications, the symmetrical light cone can be changed
to a flat beam using an additional diffuser lens.
Installation
Press the luminaire with earth spike vertically into the soil until stability
is achieved. If necessary, compact soil around the earth spike.
Plug the floodlight’s connecting cable into the plug contact of the connecting
cable with the country-specific mains plug, or into the distribution box or
extension cable.
To ensure a sufficiently low protective conductor resistance (loop
resistance), the connecting cable of each luminaire in the system must not
exceed a length of 50m from the entry point.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 7Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise.
Replace LED module.
Please follow the installation instructions for the
LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
The following combination options are available for fitting to floodlights
with connection adapter
71 223 Screw clamp with connection adapter
71 224 Tube clamp with connection adapter
71 225 Lashing strap with connection adapter
71 226 General fastener with connection adapter
71 227 G½ mount with connection adapter
Shields and diffuser lenses that alter the light distribution are available as
accessories for these floodlights.
71 290 Exchangeable lens flat beam
71332 Shield
71 335 Cylindrical shield
Country-specific mains plugs with 0.5m connecting cable
71180 Plug type F / E: system common in
Germany and Europe
71181 Plug type G: system used in Great
Britain (“Commonwealth plug”)
71182 Plug type J: system common in
Switzerland and Liechtenstein
71183 Plug type L: system common in Italy and Greece
71184 Plug type K: system common in
Denmark and Greenland
BEGA UniLink® extension cables with socket and plug
71 186 BEGA UniLink® Extension cable 5m
71 187 BEGA UniLink® Extension cable 10m
71 188 BEGA UniLink® Extension cable 20m
BEGA UniLink® connecting cables with a plug connector and one free cable end
to connect to e.g. a conventional connection box
71 247 Connecting cable 5m with free line ends
71 256 Connecting cable 0.5m with free line ends
BEGA UniLink® distribution box with five connection sockets for the connection
of BEGA UniLink® luminaires, extension cables or additional five-way
distribution boxes
71 189 BEGA UniLink® Five-way distribution box
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass 25 000 277
LED power supply unit DEV-0352/700
LED module 3000 K LED-0800/930
LED module 4000 K LED-0800/940
Reflector 75 005 075
Gasket housing 83 000 521
Gasket Abschlussring 83 002 222
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>