MEAN WELL RSP-750 Series 750W Power Supply Owner’s Manual
- June 3, 2024
- MEAN WELL
Table of Contents
MEAN WELL RSP-750 Series 750W Power Supply
DIMENSION
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 92%
- Forced air cooling by built-in DC fan
- Output voltage and constant current level programmable
- Built-in remote ON-OFF control/ remote sense auxiliary power/ DC OK signal
- Protections: Short circuit/Overload/Over voltage/Over temperature
- Optional conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
RSP-750 is a 750W single-output enclosed type AC/DC power supply. This series operates for 90-264VAC input voltage and offers the models with the DC output mostly demanded by the industry. Each model is cooled by the built-in fan with fan speed control, working for a temperature up to 70C. Moreover, RSP-750 provides vast design flexibility by equipping various built-in functions such as output programming, remote ON-OFF control, auxiliary power, etc.
Model Encoding/ Order Information
SPECIFICATION
MODEL| RSP-750-5| RSP-750-12| RSP-750-15| RSP-750-24|
RSP-750-27| RSP-750-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 48V
RATED CURRENT| 100A| 62.5A| 50A| 31.3A| 27.8A| 15.7A
CURRENT RANGE| 0 ~ 100A| 0 ~ 62.5A| 0 ~ 50A| 0 ~ 31.3A| 0 ~ 27.8A| 0 ~
15.7A
RATED POWER| 500W| 750W| 750W| 751.2W| 750.6W| 753.6W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 4.75 ~ 5.5V| 10 ~ 13.5V| 13.5 ~ 16.5V| 20 ~ 26.4V|
24 ~ 30V| 43 ~ 55V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms at full load
HOLD UP TIME (Typ.)**| 16ms/230VAC 16ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 0.97/230VAC 0.98/115VAC at full load
EFFICIENCY (Typ.)| 82%| 87%| 89%| 90.5%| 90.5%| 92%
AC CURRENT (Typ.)| 5V : 5.6A/115VAC 2.8A/230VAC
12V~48V : 8.2A/115VAC 3.9A/230VAC
INRUSH CURRENT (Typ.)| 25A/115VAC 40A/230VAC
LEAKAGE CURRENT| <2.0mA / 240VAC
PROTECTION
| OVERLOAD| 105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE (OVP)| 5.75 ~ 6.75V| 13.8 ~ 16.8V| 17 ~ 20.5V| 27.6 ~
32.4V| 31 ~ 36.5V| 56.6 ~ 66.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION
| OUTPUT VOLTAGE PROGRAMMABLE(PV)| Adjustment of output voltage
is allowable to 40 ~ 110% of nominal output voltage. Please refer to the
Function Manual.
CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)| Adjustment of
constant current level is allowable to 40 ~ 110% of rated current. Please
refer to the Function Manual.
AUXILIARY POWER| 12V @ 0.1A ; tolerance : ±10%
REMOTE ON-OFF CONTROL| Power on : short between Remote ON-OFF(pin13)
& 12V-AUX(pin14) on CN50 Power off : open between Remote ON-OFF(pin13)
& 12-AUX(pin14) on CN50
DC OK SIGNAL| The TTL signal out, power supply turn on = 0 ~ 1V ; power
supply turn off = 3.3 ~ 5.6V
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 7)
| SAFETY STANDARDS| UL62368-1, CSA C22.2 No. 62368-1, TUV BS
EN/EN62368-1, CCC GB4943.1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004
approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class B
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN61000-6-2, CCC GB17625.1,GB/T9254, BSMI CNS13438
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 1036.8K hrs min. Telcordia SR-332 (Bellcore) ; 109.2K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 25012741mm (LWH)
PACKING| 1.64Kg; 6pcs/10.8Kg/1.1CUFT
Block Diagram
Static Characteristics
Derating Curve
Efficiency vs Load (48V Model)
- The curve above is measured at 230VAC.
Function Manual
Remote Sense
- The remote sensing compensates voltage drop on the load wiring up to 0.5V.
- The +S signal should be connected to the positive terminal of the load whereas-S signal to the negative terminal.
- By factory default, on CN50, Remote ON-OFF (pin13) and 12V-AUX (pin14), PV(pin5) and PS (pin6), and PC (pin7) and PO (pin8, respectively, are shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functions needs to be activated.
Remote ON-OFF
- The power supply can be turned ON/OFF by using the “Remote ON-OFF” function.
Between Remote ON-OFF(pin13) and 12V-AUX(pin14) | Power Supply Status |
---|---|
SW close (Short) | ON |
SW open (Open) | OFF |
When multiple power supplies need to turn ON/OFF simultaneously by Remote ON- OFF control, -S & -V on CN50, as well as +S & +V, on each power supply should be connected.
Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying EXTERNAL VOLTAGE.
- If EXTERNAL VOLTAGE (VDC) <0.5V, the power supply may enter under voltage protection; it needs to be restarted to work.
Caution: By factory default, the Output Voltage Programming is not
activated, and PV (pin5) and PS(pin6) are shorted by a connector. Whenever
this
function is not needed to activate, as assumed in other sections’ diagrams,
please keep PV (pin5) and PS(pin6) shorted; otherwise, the power supply will
have no output.
Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)
- The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE.
Caution: By factory default, the Output Current Programming is not
activated, and PC(pin7) and PO(pin8) are shorted by connector. Whenever this
function is not needed to activate, as assumed in other sections’ diagrams,
please keep PC(pin7) and PO(pin8) shorted; otherwise, the power supply will
have no output.
DC_OK signal
- “DC_OK” is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external
- TTL signal ; the other is sending out a TTL voltage signal.
- Sinking current from external TTL signal: The maximum sink current is 10mA and the maximum external voltage is 5.6V.
- Sending out TTL voltage signal
Between DC- OK(pin9) and GND(pin10&11) | Output Status |
---|---|
0 ~ 1V | Power supply ON |
3.3 ~ 5.6V | Power supply OFF |
Mechanical Specification
Mounting Instruction
Hole No.| Recommended Screw Size| MAX. Penetration Depth L| Recommended
mounting torque
---|---|---|---
1| M4| 6mm| 7~11Kgf-cm
2| M4| 4mm| 7~11Kgf-cm
Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent
Mating Housing | HRS DF11-14DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function | Description |
---|---|---|
1 | +S | Positive sensing for remote sensing. |
2 | +VS | +V Signal. The +VS should be connected to the +S to reduce the noise |
when the “output voltage programming” function is in use.
3| -S| Negative sensing for remote sense.
4| -VS| -V Signal. The -VS should be connected to the -S to reduce the noise
when “output voltage programming” function is in use.
5| PV| Connect to external DC voltage source for output voltage programming,
referenced to pin 10,11 (GND).
6| PS| Reference pin regarding output voltage programming. Please refer to the
Function Manual.
7| PC| Connect to external DC voltage source for output current programming.
8| PO| Reference pin regarding output current programming. Please refer to the
Function Manual.
9| DC_OK| Open collector signal, referenced to pin10,11(GND). Low when PSU
turns on. The maximum sink current is 10mA and the maximum external voltage is
5.6V.
10,11| GND| These pins connect to the negative terminal (-V). Return for DC_OK
Signal output.
12| G-AUX| Auxiliary voltage output ground.
The signal return is isolated from the output terminals (+V & -V).
13| REMOTE ON-OFF| Turns the output on and off by electrical or dry contact
between pin 13 ( ON/OFF) and pin 14 (12V-AUX). Short: Power ON, Open: Power
OFF.
14| 12V-AUX| Auxiliary voltage output, 10.8~13.2V, referenced to pin
12(G-AUX).
The maximum load current is 0.1A. This output is not controlled by the “remote ON/OFF control”.
AC Input Terminal Pin No. Assignment
Pin No. | Assignment | Diagram | Maximum mounting torque |
---|---|---|---|
1 | AC/N |
18Kgf-cm
2| AC/L
3| FG| |
DC Output Terminal Pin No. Assignment
Assignment | Diagram | Maximum mounting torque |
---|
+V, -V
|
|
10Kgf-cm
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>