With CG17 you can install a simple intruder alarm system. You can remotely control gates, heating or ventilation systems and other equipment, and control the temperature.

You can monitor and control the system with Protegus2 application, phone call or SMS.

CG17 can call and inform about events by SMS messages and notifications in the Protegus2 app.

This manual describes how to install CG17 without configuring it via USB. If needed, using Trikdis Config program or SMS commands you can:
– Add and delete users (8 users);
– Set dual purpose contacts to operate in input or output mode;
– Set the input type (NC, NO, EOL) and output type (pulse, level);
– Set automatic output control algorithm, so that if the temperature rises to a certain level, the relay status is changed;
– Connect iO expanders, iButton electronic key reader TM17;
– Turn on event reporting to security company receiver;
– Customize what SMS text will be sent after an input or output is activated or restored;
– Etc.

The list of SMS commands is at the end of this manual. Find TrikdisConfig configuration program, product specifications and instruction at www.trikdis.com.

I. Installation and wiring

  1. Remove the upper cover, pull out the terminal block connectors.

  2. Take out the PCB board from the casing. Fix the casing to desired place with self-tapping screws.

  3. Place the PCB board back into the casing. Insert the terminal blocks.

  4. Screw the GSM antenna to the antenna connector.

  5. Place a Nano size SIM card to the SIM card slot.
    !! It is necessary to disable the SIM card PIN code request before inserting the SIM to CG17!
    You can do this using a mobile phone. Alternatively, you can enter the SIM card PIN via TrikdisConfig program using a USB.

  6. Following the connection scheme, connect the wires. Then connect the power supply:TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction Manual - Following the connection scheme
    6.1. Connect the sensors (motion, fire, magnetic contact or other) to inputs following these schemes:TRIKDIS CG17 3G Multifunctional Security Control
Panel Instruction Manual - Connect the sensors
    6.2. You can connect 1-Wire® (DS18S20, DS18B20) temperature sensor:
    6.3. You can connect a siren:
    Nominal current for 5 OUT and 6 OUT outputs is up to 1A; nominal current for 2 I/O, 3 I/O, 4 I/O outputs ­ up to 0,1A. If you want to connect the siren to other output than 6 OUT, go to TrikdisConfig , assign function Siren to that output and specify the alarm area.
    6.4. Connect iButton electronic key reader TM17. In order to enable the key reader, you have to add it in TrikdisConfig window Modules, in card RS485 modules. You have to assign an alarm area to TM17 and enter TM17 serial number. Add iButton keys in window Users and Notifications, in card iButton keys.TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction
Manual - Connect iButton electronic key
    6.5. You can also connect electronic key reader from other manufacturer:TRIKDIS CG17 3G Multifunctional Security Control Panel
Instruction Manual - You can also connect electronic key
    6.6. You can connect the fire detector following one of these schemes:TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction
Manual - You can connect the fire detector
    6.7. You can connect devices to outputs OUT or I/O, so that they could be controlled remotely. Assign function “Remote control” to the output in TrikdisConfig. You can see some examples below:TRIKDIS CG17 3G
Multifunctional Security Control Panel Instruction Manual - You can connect
devices
    Automatic output control algorithm is described in the full CG17 installation manual.

  7. Turn on the power supply. This LED indication must show:
    – “POWER” – LED is blinking green;
    – “NETWORK” – LED is solid green for 3-4 seconds and blinks yellow 1 to 5 times depending on GSM signal strength.

  8. You successfully connected CG17 and it is ready for operation.

Purpose of terminals

TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction Manual -
Purpose of terminals

LED indication

TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction Manual -
LED indication

II. Remote control with Protegus2 app

You can remotely control CG17 using Protegus2 application, see system status and receive notifications about system events.
Also connect to Protegus2 if you want to remotely configure CG17 via TrikdisConfig.

Internet connection is necessary for communication with Protegus2. Make sure that internet access is enabled for the SIM inserted into CG17.

1. Turn on the internet access for CG17

To enable connection with Protegus2, send an SMS in such format to the telephone number of SIM card inserted in the CG17:

CONNECT xxxxxx PROTEGUS=ON,APN=INTERNET

xxxxxx 6-digit administrator password (default password – 123456)
PROTEGUS=ON Command to start communication with Protegus
INTERNET SIM card provider‘s wireless internet APN value (often “internet” is suitable)

Connecting CG17 to internet and Protegus2 takes around one minute.
You can also turn on Protegus via TrikdisConfig: in window “IP reporting” tick the checkbox “Protegus Cloud”.

2. Connect and add CG17 to Protegus2

  1. Download and run the Protegus2 application or use the version online www.protegus.app:https://apps.apple.com/jp/app/protegus-2/id1555450252?l=en-UShttps://play.google.com/store/apps/details?id=lt.apps.protegus2&hl=en&gl=US
  2. Log in with your user name. If you haven`t used the app before, register as a new user.
  3. Click on Add new system and type in CG17 “Unique ID” number. “IMEI/Unique ID” is on the device and the packaging sticker.

If CG17 is not connected to the internet when you add a new system, the system will be added with limited functionality. When you connect CG17 to the internet, go to system settings and in window “System information” click “Re- read system config”.

3. Control the system via Protegus2 application

  1. Go to Protegus2 application and in system window press the “ARM” button.
  2. Enter the user code (default ­ 1234).
  3. The system will be armed.

4. Add other users

  1. In the Protegus2 application, in the system window, go to menu “System configuration” and then go to “Users”.

  2. Select user.

  3. In the window that opens enter the user information:
    · After entering the users email address, the user will get access to Protegus2; · After entering phone number, the user will be able to control the system via phone calls or SMS; · After entering user code, the user will get a separate password to control the system. Without this code, the user will be able to control the system with Master or other users password.

  4. When you enter all users, press button to “Save” the changes.

III. Remote control via phone call

  1. Make a call to the number of the inserted SIM card.
  2. CG17 will answer and you can enter control commands using the phone keypad .

If there are no added users, the first one to call to CG17 will become the system administrator and will be the only one able to control CG17 via phone calls and SMS commands.
If you want other users to control the system via phone call, add them via TrikdisConfig or SMS commands.
You can find the detailed command list in the full CG17 instruction.

IV. Remote control and configuration via SMS

  1. Turn on and off the security system via SMS
    ARM xxxxxx SYS:x DISARM xxxxxx SYS:x
    xxxxxx x 6-digit administrator password (default password ­ 123456) Alarm area number (1-8)

  2. Change the administrator password
    To ensure safety, change the default administrator password. Send an SMS in this format:
    123456 xxxxxx PSW 123456 xxxxxx
    Default administrator password The new 6-digit administrator password

  3. Give control rights to other users
    Only phone numbers added to the user list can control the system via SMS or phone call. Send an SMS from the administrators phone with new users phone numbers and names so that they could control the system:
    SETN xxxxxx PHONEx=+PHONENR#NAME
    xxxxxx 6-digit administrator password
    x User‘s number on the list
    PHONENR User‘s phone number
    NAME User‘s name
    If you enter “1” in the SMS, you will transfer the administrator`s rights to another user.

  4. Reset the smoke detectors Reset the smoke detectors remotely via SMS:
    FRS xxxxxx
    xxxxxx 6-digit administrator password

The output, that the smoke sensors are connected to, has to have an assigned type “Restore fire sensors”. By default settings it is 5OUT output.

Full SMS command list

TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction Manual -
Full SMS command list TRIKDIS CG17 3G Multifunctional Security
Control Panel Instruction Manual - Full SMS command list TRIKDIS CG17 3G
Multifunctional Security Control Panel Instruction Manual - Full SMS command
list TRIKDIS CG17 3G Multifunctional Security Control Panel
Instruction Manual - Full SMS command list TRIKDIS CG17 3G
Multifunctional Security Control Panel Instruction Manual - Full SMS command
list

V. Remote configuration via TrikdisConfig

If needed, you can configure CG17 with program TrikdisConfig via USB or remotely.

  1. Download TrikdisConfig from www.trikdis.com.

  2. Make sure that CG17 is connected to the internet and communication with Protegus2 is enabled (see part II. Remote control via Protegus2 application).

  3. After opening the program, enter “IMEI/Unique ID” number to “Unique ID” field and click ,,Configure”:TRIKDIS CG17 3G Multifunctional Security Control Panel Instruction Manual - After opening the program
    In the program, every field is explained with hints that appear after holding the mouse pointer on the required field.

  4. Click Read [F4] to read the parameters already set in CG17.

  5. Set the needed settings and after the job is finished click Save [F5].