TRIKDIS FLEXi SP3 Smart Security Panel Installation Guide
- June 13, 2024
- TRIKDIS
Table of Contents
TRIKDIS FLEXi SP3 Smart Security Panel
Full installation instructions are available at: www.trikdis.com
Safety precautions
Power supply must be unplugged during installation!
The panel is not resistant to vibrations, other mechanical effects, humidity
and aggressive chemical environments. The control panel complies with the
demands applicable to Class II environmental specification of the EN 50131
standard.
The casings, transformers, batteries and programming equipment used must meet
the safety requirements of the EN 60950 standard. The device is powered from a
110-230 V voltage
50-60 Hz frequency power grid through a Class II step-down 40VA transformer
that reduces the voltage to 16 – 18 V or from a 16 – 24 V DC power supply
unit. A 12 V battery with at least 7 Ah capacity is used as a backup power
supply. The current consumption depends on the power of the connected external
devices.
Technical Support and help
How to start FLEXi SP3 with Protegus 2 app for programming
See how to connect a system with default settings on the other side. (No
programming required.)
Power supply must be unplugged during installation!
For programming:
- Create user
- Press Add System, and follow further instructions.
For FLEXi SP3 programming go to:
= ► Settings ► Advanced settings
- Make sure the SIM card is inserted correctly
- Make sure the SIM card mobile data is activated
- SIM card is locked. Unlock the SIM card and disable PIN code with your mobile device.
Make sure your APN settings are correct To change APN, send the SMS:
connect 123456 apn=apnname
e.g. connect 123456 apn=internet
LED indication
You can also configure with Trikdisconflg software:
- with USB cable
- remotely*
(FLEXi SP3 must be connected to the Protegus cloud service)
Default Setting
Wiring Instruction
The FLEXI SP3 must be Installed and serviced only by qualified personnel.
Full installation instructions are available at:
www.trikdis.com
If you do not use some of 101-109 terminals, terminate with 2.2 kn resistors as shown. You can also disable unused zones in Zone settings.