TRIKDIS FLEXi SP3 Smart Security Panel Installation Guide

October 31, 2023
TRIKDIS

TRIKDIS FLEXi SP3 Smart Security Panel

Full installation instructions are available at: www.trikdis.com

Safety precautions
Power supply must be unplugged during installation!
The panel is not resistant to vibrations, other mechanical effects, humidity and aggressive chemical environments. The control panel complies with the demands applicable to Class II environmental specification of the EN 50131 standard.
The casings, transformers, batteries and programming equipment used must meet the safety requirements of the EN 60950 standard. The device is powered from a 110-230 V voltage
50-60 Hz frequency power grid through a Class II step-down 40VA transformer that reduces the voltage to 16 – 18 V or from a 16 – 24 V DC power supply unit. A 12 V battery with at least 7 Ah capacity is used as a backup power supply. The current consumption depends on the power of the connected external devices.
Technical Support and help

TRIKDIS-FLEXi-SP3-Smart-Security-Panel- \(1\)

trikdis.com/help/

How to start FLEXi SP3 with Protegus 2 app for programming

TRIKDIS-FLEXi-SP3-Smart-Security-Panel- \(2\)

See how to connect a system with default settings on the other side. (No programming required.)
Power supply must be unplugged during installation!

For programming:

  • Create user
  • Press Add System, and follow further instructions.

For FLEXi SP3 programming go to:
= ► Settings ► Advanced settings

  • Make sure the SIM card is inserted correctly
  • Make sure the SIM card mobile data is activated
  • SIM card is locked. Unlock the SIM card and disable PIN code with your mobile device.

Make sure your APN settings are correct To change APN, send the SMS:
connect 123456 apn=apnname
e.g. connect 123456 apn=internet

LED indication

You can also configure with Trikdisconflg software:

  • with USB cable
  • remotely*

(FLEXi SP3 must be connected to the Protegus cloud service)

Default Setting

TRIKDIS-FLEXi-SP3-Smart-Security-Panel- \(19\)

Wiring Instruction

The FLEXI SP3 must be Installed and serviced only by qualified personnel.
Full installation instructions are available at: www.trikdis.com

If you do not use some of 101-109 terminals, terminate with 2.2 kn resistors as shown. You can also disable unused zones in Zone settings.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>