BEGA 85 152 Performance Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
Technical amendments reserved
Performance floodlight
85 152
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver Matt safety glass Silicone gasket
Reflector surface made of pure aluminium BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+95°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical
impacts < 5 joule
– Conformity mark
Wind catching area: 0.053 m²
Weight: 6.8 kg
This product contains light sources of energy efficiency class(es) F
Lighting technology
Focused light distribution with minimal diffuse light percentage.
Half beam angle 10°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 6 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 12 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screw (wrench size 2 mm, see sketch B).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow ( ****), the phase to the brown (L), and the
neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp|
---|---
Module connected wattage| 102.8 W
Luminaire connected wattage| 114 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 30 °C
85 152 K3|
Module designation| 4x LED-1145/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 12560 lm
Luminaire luminous flux| 6158 lm
Luminaire luminous efficiency| 54 lm / W
85 152 K4|
Module designation| 4x ED-1145/940
Colour temperature| 4000 K
Colour rendering index| CRI > 90
Module luminous flux| 13200 lm
Luminaire luminous flux| 6472 lm
Luminaire luminous efficiency| 56,8 lm / W
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected
regarding obvious damages and has to be replaced by a qualified electrician
only.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted
on a separate label in the luminaire or on the
underside of the specific LED module.
The light colour and light output of BEGA
replacement modules correspond to those
of the modules originally fitted. The module
can be replaced by qualified persons using
standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench
size 2.5 mm) on the back side of the floodlight
housing.
Remove the trim ring along with the safety
glass and reflector by twisting it counterclockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 292 | Optical filter flat beam |
---|---|
71 334 | Shield |
71 339 | Cylindrical shield |
70 214 | Pole cap for pole top ø 48 mm |
70 248 | Pole cap for pole top ø 60 mm |
70 249 | Pole cap for pole top ø 76 mm |
70 229 | Pole cap for pole top ø 82 mm |
70 245 | Mounting box · rectangular |
70 280 | Tube clamp |
70 379 | Cross beam |
70 889 | Lashing strap |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass
Trim ring silver with glass
LED power supply unit
LED module 3000 K
LED module 4000 K
Gasket housing
Gasket trim ring| 25 000 305
25 000 306
DEV-0363/700
LED-1145/930
LED-1145/940
83 001 780
83 002 225
---|---
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>