BEGA 85 100 Pole Top Luminaire

DIMENSION

Pole top luminaire

BEGA-85-100-Pole-Top-Luminaire-fig-1

Instructions for use

Application
Pole-top luminaire with symmetrical light distribution. With an upward-facing interface for the installation of light management components in accordance with Zhaga Book 18 Ed. 3.0 (Z-LEX-R), suitable for components Zhaga Book 18 Ed. 3.0 (Z-LEX-M), e.g. Zhaga Air Connector 71 210) For mounting heights 3500 – 6000 mm.

Product Description

  • Luminaire made of cast aluminium, aluminum and stainless steel
  • BEGA Unidure® coating technology
  • Color graphite or silver
  • Clear, impact-resistant synthetic sphere
  • For pole, top ø 76 mm
  • Slip fitter insert depth 65 mm
  • 1 built-in interface according to
  • Zhaga Book 18 Ed. 3.0 (Z-LEX-R) with closing cap in the luminaire head
  • Connecting cable H05RN-F 2 × 1@
  • Cable length 6 m
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-280 V
  • During DC operation the LED power is reduced to 15 %
  • Safety class II
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • Conformity mark
  • Horizontal wind-catching area: 0.16 m² Weight: 4.9 kg
  • This product contains light sources of energy efficiency class(es) C

Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. Less than 1 % of the luminaire luminous flux is emitted into the upper half-space of the luminaire.

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 24 W
  • Luminaire connected wattage 27.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

85 100 K3

  • Module designation LED-1281/830
  • Color temperature 3000 K
  • Color rendering index CRI > 80
  • Module luminous flux 3970 lm
  • Luminaire luminous flux 2592 lm
  • Luminaire luminous efficiency 94,3 lm / W

85 100 K4

  • Module designation LED-1281/840
  • Color temperature 4000 K
  • Color rendering index CRI > 80
  • Module luminous flux 4170 lm
  • Luminaire luminous flux 2722 lm
  • Luminaire luminous efficiency 99 lm / W

Installation

When selecting a light management component, ensure that it is suitable for use in the upward-facing Zhaga fitting. For the installation of light management components according to Zhaga Book 18, remove the factor-installed closing cap from the luminaire housing by twisting it anti-clockwise. Insert the light management components into the socket and turn them clockwise until they stop. Please observe the manufacturer’s operating instructions and data sheets. The luminaire may only be operated with inserted Zhaga components or closing caps. Lead luminaire connecting cable into the pole and put on luminaire. Align the luminaire and fix it. Fix lateral hexagon socket head screws M8 firmly. The electrical connection of the luminaire must be made with the appropriate protection class and safety class using suitable connection terminals (not included in the scope of delivery) on the luminaire power supply cable. We recommend you use BEGA connection boxes for this purpose. Note the correct configuration of the main supply cable. The phase is connected to the brown wire (L) and the neutral conductor to the blue wire (N). In case these interfaces are not used the luminaire will be operated at full light output.

Please note:
Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by a qualified person using commercially available tools. Disconnect the system from the power supply. Loosen the hexagon socket screws (wrench size 4) in the cover of the synthetic sphere and lift off the cover.
  • Undo the three mounting screws (Torx drive T20) on the LED carrier and remove the LED carrier.
  • Disconnect the plug connector of the LED connecting cable.
  • Unclip the grey synthetic cover on the LED carrier.
  • Replace the LED module. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. A defective synthetic sphere must be replaced.
  • Install the luminaire in reverse order.

Accessories

For this luminaire, we recommend the following luminaire poles: Tapered aluminium poles · lacquered with access door and C-clamp

  • 70 913 Pole with anch.section H 3500 mm
  • 70 914 Pole with anch.section H 4000 mm
  • 70 725 Pole with anch.section H 4500 mm
  • 70 915 Pole with anch.section H 5000 mm
  • 70 916 Pole with anch.section H 6000 mm
  • 70 789 Pole with baseplate H 3500 mm
  • 70 791 Pole with baseplate H 4000 mm
  • 70 792 Pole with baseplate H 4500 mm
  • 70 794 Pole with baseplate H 5000 mm

Cylindrically stepped aluminum poles lacquered · with door und C rail

  • 70 901 Pole with anch.section H 4000 mm
  • 70 903 Pole with anch.section H 5000 mm
  • 70 905 Pole with anch.section H 6000 mm

Please see the instructions for use of the luminaire poles for suitable connection boxes.

Spares

  • Clear synthetic sphere 15 000 798
  • LED power supply unit DEV-0395/700i
  • Zhaga Lampholder 63 000 577
  • LED module 3000 K LED-1281/830
  • LED module 4000 K LED-1281/840
  • Reflector 76 002 088
  • Gasket bottom interior 83 001 990
  • Gasket bottom exterior 83 002 047
  • Gasket globe top 83 002 274

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com