Product Information
Specifications
- Module connected wattage: 10.8 W
- Luminaire connected wattage: 12.5 W
- Rated temperature: 25°C to 50°C
- Ambient temperature: 25°C to 50°C
- Color temperature: 3000 K or 4000 K
- Colour rendering index (CRI): >90
- Module luminous flux: 1270 lm to 1345 lm
- Luminaire luminous flux: 601 lm to 636 lm
- Luminaire luminous efficiency: 48.1 lm/W to 50.9 lm/W
Product Usage Instructions
Safety
- The installation and operation of this luminaire should only be carried out by a qualified electrician in compliance with national safety regulations. The manufacturer is not liable for damages due to improper use or installation.
Overvoltage Protection
- The electronic components have built-in protection against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
Maintenance
- Regularly inspect the connecting cable for damages and replace it if necessary by a qualified electrician. Do not remove the desiccant bag from the luminaire housing as it helps remove residual moisture.
Accessories
Optional accessories like optical filters and shields are available for this product. Separate instructions for using these accessories can be provided upon request.
Spares
- Available spare parts include trim rings, LED power supply units, LED modules in different color temperatures, reflectors, gaskets for housing, and trim rings.
FAQ
Q: Can I install the luminaire myself?
A: No, installation should only be done by a qualified electrician.
Q: What should I do if I notice visible damage to the connecting cable?
A: Contact a qualified electrician for inspection and replacement if needed.
Q: Can I use the luminaire without the desiccant bag?
A: No, the desiccant bag should not be removed as it helps remove moisture.
Dimension
Instructions for use
Application
- Performance floodlight with G½ mounting bush.
- The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories. For a variety of interior and exterior lighting applications.
Product Description
- Luminaire made of aluminum alloy, aluminum, and stainless steel
- BEGA Unidure® coating technology
- Color graphite or silver
- Matt safety glass
- Silicone gasket
- Reflector surface made of pure aluminum BEGA Hybrid Optics®
- The rotation range of floodlight is 350°
- Swivel range -30°/+100°
- Mounting bracket with G½ threaded connection
- Thread length: 14 mm
- Connecting cable X05BQ-F 5 G 1 mm²
- Cable length 1 m
- Complies with flicker requirements by IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK07
- Protection against mechanical impacts < 2 joule
- Conformity mark
- Wind catching area: 0.017 m²
- Weight: 1.3 kg
- This product contains light sources of energy efficiency class(es) E, F
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Installation
- Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
- G½ threaded connection torque = 40 Nm. Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
- Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.
Adjust floodlight:
- Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C).
Torque:
- Hexagon socket screw = 7 Nm
- Hexagon nut = 35 Nm
- Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).
- The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
- Note the correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow (1), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
- The connection of the control cables is achieved through both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.
Lamp
- Module connected wattage 10.8 W
- Luminaire connected wattage 12.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
85 149 K3
- Module designation LED -1147/930
- Color temperature 3000 K
- Color rendering index CRI > 90
- Module luminous flux 1270 lm
- Luminaire luminous flux 601 lm
- Luminaire luminous efficiency 48,1 lm / W
85 149 K4
- Module designation LED -1147/940
- Color temperature 4 000 K
- Color rendering index CRI > 90
- Module luminous flux 1345 lm
- Luminaire luminous flux 636 lm
- Luminaire luminous efficiency 50,9 lm / W
Lighting technology
- Focused light distribution with minimal diffuse light percentage.
- Half beam angle 8°
- For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Maintenance
- The connecting cable between the mounting box and the floodlight has to be inspected for obvious damages and has to be replaced by a qualified electrician only.
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
- Disconnect the system from the power supply.
Open the floodlight:
- Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
- Replace the LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
- Twist on the trim ring clockwise as far as the stop.
Accessories
- 71 289 Optical filter flat beam
- 71 331 Shield
- 71 336 Cylindrical shield
- 70 214 Pole cap for pole ø 48 mm
- 70 248 Pole cap for pole ø 60 mm
- 70 245 Mounting box
- 70 252 General fastener
- 70 280 Tube clamp G½
- 70 283 Screw clamp
- 70 379 Crossbeam G½
- 70 889 Tension belt
- For the accessories, separate instructions for use can be provided upon request.
Spares
- Trim ring graphite with glass 25 000 250
- Trim ring silver with glass 25 000 251
- LED power supply unit DEV-0348/300
- LED module 3000 K LED-1147/930
- LED module 4000 K LED-1147/940
- Reflector 75 005 107
- Gasket housing 83 000 486
- Gasket trim ring 83 002 169
- BEGA Gantenbrink-Leuchten KG
- Postfach 31 60
- 58689 Menden
- info@bega.com
- www.bega.com
Documents / Resources
| BEGA
85149 Performance
Floodlight
[pdf] Instruction Manual
85149, 85149 Performance Floodlight, Performance Floodlight, Floodlight
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>