BEGA 50 039 P Ceiling and Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 50 039 P Ceiling and Wall Luminaire

Specifications:

  • Lamp Module connected wattage: 8.2 W
  • Luminaire connected wattage: 10.5 W
  • Rated temperature: 25-40°C
  • Ambient temperature: max. 25°C

Product Usage Instructions

  • Luminaire Installation:
    Before installing the luminaire onto the mounting surface, the luminaire housing must be inserted into the trim ring (accessory).

  • Synthetic Diffuser Removal:
    To release the synthetic diffuser from the luminaire housing, turn it counter- clockwise.

  • Mounting Heights:
    The maximum wall mounting height is 4.0 m and the maximum ceiling mounting height is 6.0 m, with reduced range at these heights.

  • Motion Sensor Installation:

    • For luminaires with HF motion sensors, ensure that the installation distance between two luminaires is more than 2 meters to prevent incorrect triggering of the sensors.
    • Local conditions can impact both the range and detection area of the motion sensors.

FAQ:

  • Q: Can I install the luminaire without a qualified electrician?
    A: No, installation and commissioning must be carried out by a qualified electrician to ensure safety and compliance with regulations.

  • Q: Where can I find additional overvoltage protection components?
    A: Additional overvoltage protection components can be found on our website at www.bega.com.

  • Q: What are the maximum mounting heights for the luminaire?
    A: The maximum wall mounting height is 4.0 m and the maximum ceiling mounting height is 6.0 m, with a reduced range at these heights.

Ceiling and wall luminaire for indoor use

BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig- \(1\)

Instructions for use

Application

  • Ceiling and wall luminaire · indoor luminaire made of impact resistant synthetic diffuser and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
  • Luminaire with motion sensor.

Product description

  • Metal housing, finish colour white
  • Impact resistant synthetic diffuser, white, with bayonet closure
  • Integrated HF-motion sensor,
  • maximum range 10 m
  • 2 mounting holes ø 5.5 mm
  • Distance apart 180 mm
  • 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connection terminal 2.5@
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V ~ 50/60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  •  – Conformity mark
  • This product contains light sources of energy efficiency class(es) D, E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to
    the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lighting technology

Luminaire data for the DIALux lighting design program for outdoor lighting, street lighting and indoor lighting, as well as luminaire data in EULUMDAT and IES format are available on the BEGA website at www.bega.com.

  • Lamp
    • Module connected wattage 8.2 W
    • Luminaire connected wattage 10.5 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 40 °C
  • 50 039 P K27
    • Colour temperature 2700 K
    • Colour rendering index CRI > 90
    • Module luminous flux 1165 lm
    • Luminaire luminous flux 951 lm
    • Luminaire luminous efficiency 90,6 lm / W
  • 50 039 P K3
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 1205 lm
    • Luminaire luminous flux 985 lm
    • Luminaire luminous efficiency 93,8 lm / W
  • 50 039 P K4
    • Colour temperature 4000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 1255 lm
    • Luminaire luminous flux 1026 lm
    • Luminaire luminous efficiency 97,7 lm / W

Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Pass the mains supply cable through the grommet into luminaire housing.
  • Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
  • It is imperative to use the enclosed gaskets. Dismantle the mains supply cable approx. 60 mm.
  • Make earth and electrical connection to the terminals.
  • Place the synthetic diffuser to the luminaire housing and observe that the cam pins fit into the notches of the synthetic diffuser.
  • Screw in synthetic diffuser by turning it clockwise.
  • Thus, you reach a safe and vibration- resistant holding of the synthetic diffuser.
  • To release the synthetic diffuser from the luminaire housing, turn it counter-clockwise.BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig- \(3\)
  • The built-in motion sensor operates at a frequency of 5.8 GHz.
  • Detection range: 30° to 150°.
  • Operating temperature: -35° C to +70° C. With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the maximum range is 9 / 10 meters (see sketch).BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig- \(4\)
  • The max. wall mounting height is 4.0 m and the max. ceiling mounting height is 6.0 m, in which the range reduces significantly.
  • Note: The installation distance between 2 luminaires with HF motion sensors should be more than 2 metres to prevent the sensors from being triggered incorrectly.
  • Local conditions can affect both the range and the detection area.BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig- \(5\)

Detection Range

  • The sensor sensitivity (10% to 100%) can be precisely set for each specific application by selecting the combination on DIP switches 1-3.
  • Please note that a reduction in sensitivity also leads to a reduction in the range.BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig- \(6\)

Dwell time
By moving within the detection range the motion sensor switches on the LED module inside the luminaire with a defined dwell time. Select the DIP switch position 1-4 for the light switch-on time (5 s to 30 min.) after presence detection.
This function is deactivated if natural daylight is sufficient (exception: the threshold is deactivated).BEGA-50-039-P-Ceiling-and-Wall-Luminaire-fig-
\(7\)

Daylight threshold

  • Use DIP switches 1-4 to set the sensor level according to the lighting and the surroundings. The light does not switch on if the ambient brightness exceeds the set daylight threshold.

  • Please note that the ambient brightness refers to the internal light that reaches the sensor.

  • If you deactivate the daylight sensor, the sensor switches to “Presence detection only” mode.

  • To set the luminaire to switch on and off automatically when it is dark or light outside, follow these steps:

    • Quick switch on and off:
      You can switch the luminaire on and off quickly by simply pressing the switch (light switch) twice. The green LED indicator on the HF sensor flashes slowly for 5 seconds and the luminaire flashes twice.

    • Measurement of daylight:
      The sensor measures the brightness of the surroundings for 1 second and stores this information.

    • Confirmation :
      The luminaire is then in operation and the green LED indicator lights up for 10 seconds to indicate that the setting was successful. Thanks to this function, the luminaire can work well even if the daylight outside varies greatly. It is important to note that the last measured ambient light value always replaces the previous value. In addition, both the setting on the switch and the measured brightness value can replace each other.
      The last action that was carried out remains valid.

Note: You can display the DIP switch settings via smartphone or tablet by scanning the QR code on the housing of the HF sensor.

Replacement of the LED unit

  • The designation of the LED unit is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Unscrew synthetic diffuser from luminaire housing by turning it counter-clockwise. Disassemble LED unit.
  • Assemble LED replacement unit.
  • Note installation instructions of the LED unit. Screw in synthetic diffuser by turning it clockwise.
  • A damaged synthetic diffuser must be replaced.

Accessory · Trim rings

  • For this luminaire metal trim rings in 3 enamel surfaces are optional available.
  • Trim rings are accessories and must be ordered separately.
  • Item Part. No
  • Colour white 13 001
  • Colour palladium 13 002
  • Colour glossy silver 13 003

Spares

  • Synthetic cover 15 000 455
  • HF-motion sensor 61 002 191
  • LED unit 2700 K 75 003 045 K27
  • LED unit 3000 K 75 003 045 K3
  • LED unit 4000 K 75 003 045 K4

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>