BEGA 24 909 Recessed Ceiling Luminaire Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 24 909 Recessed Ceiling Luminaire
Specifications
- Product Name: Recessed Ceiling Luminaire
- Model Number: 24 909
- Application: Suitable for installation in concrete ceilings or suspended ceilings indoors and outdoors
- Light Distribution: Symmetrical wide beam
- Lamp Module Connected Wattage : 21.5 W
- Luminaire Connected Wattage: 25 W
- Colour Temperature: 3000 K (LED-1630/830) and 4000 K (LED-1630/840)
- Colour Rendering Index (CRI) : > 80
- Luminous Flux: 4430 lm to 4545 lm
- Luminaire Luminous Efficiency: 130 lm/W to 133.4 lm/W
Product Usage Instructions
- Insert the luminaire housing into the recessed opening carefully.
- Hand-tighten the screws of the claw fastener using a Torx drive T15 evenly. Do not use an electric screwdriver for this step.
- Ensure that when tightening the screws, the fixing claws swivel onto the inside of the suspended ceiling to securely fix the luminaire in place.
- When undoing the guide screws, the fixing claws swivel back, allowing you to remove the luminaire if needed.
- Important: Do not remove the desiccant bag from the luminaire housing as it is necessary to remove residual moisture.
Dimension
Instructions for use
Application
Recessed ceiling luminaire with attached connecting cable for installation
into concrete ceilings or suspended ceilings both indoors and out.
With symmetrical wide beam light distribution.
Product Description
- Luminaire made of aluminum alloy, aluminum, and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or white
- Clear safety glass
- The reflector surface is made of pure aluminum Luminaire housing with 2 fixing claws and guide screws
- Recessed opening ø 202 mm
- Required installation depth 145 mm Connecting cable X05BQ-F 5 G 1 mm² with free line ends
- Cable length 0,5 m
- Complies with flicker requirements by IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit
- 220-240 V 0/50-60 Hz
- DC 176-280 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets c – Conformity mark
- This product contains light sources of energy efficiency class(es) B
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at: www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Specification
Lamp
- Module connected wattage 21.5 W
- Luminaire connected wattage 25 W
- Rated temperature ta = 25 °C
- Service life criteria 50 000 h / L70
24 909 K3
- Module designation LED-1630/830
- Color temperature 3000 K
- Color rendering index CRI > 80
- Module luminous flux 4430 lm
- Luminaire luminous flux * 3250 lm
- Luminaire luminous efficiency * 130 lm / W
24 909 K4
- Module designation LED-1630/840
- Color temperature 4000 K
- Color rendering index CRI > 80
- Module luminous flux 4545 lm
- Luminaire luminous flux * 3334 lm
- Luminaire luminous efficiency * 133,4 lm / W
preliminary data
Lighting technology
Half beam angle 80°
Installation
- Luminaire housing must not be installed in heat-insulating material.
- The recessed opening is covered by the frame of the luminaire housing.
- Fixing of the luminaire in the structure is achieved by using two adjustable wedge-shaped claws.
- A recessed opening of ø 202 mm with a minimum depth of 145 mm is required.
- The lateral distance between the luminaire housing and parts of the building must be at least 50 mm.
- The claws grip behind the ceiling cladding. The minimum thickness of the ceiling cladding is 1 mm.
- Ensure that the suspended ceiling and wall surfaces have sufficient load-bearing capability. If the thickness is less, and if installation is to be carried out in plasterboard ceilings, the back of the ceiling cladding must be reinforced in the region of the claws.
The electrical connection of the free cable end must be carried out with
matching protection class and safety class, relieved of strain, with suitable
connection terminals in a suitable connection box (not included in the scope
of delivery).
Observe the correct configuration of the connecting cable. Make the mains
connection to the brown (L), blue (N) and green-yellow wires ( ).
The control cables are connected via the two DALI-labelled wires white-red
(wh-rd) and white-black (wh-bl). If these wires are not assigned, the
luminaire will work with full light output.
Insert luminaire housing into the recessed opening. Hand-tighten the screws of
the claw fastener (torx drive T15) evenly. Do not use an electric screwdriver!
When tightening the screws, the fixing claws must swivel onto the inside of
the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire
can be removed.
Cleaning Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Close the luminaire.
Spares
- Spare glass 14 000 289
- LED power supply unit DEV-0338/700i
- LED module 3000 K LED-1630/830
- LED module 4000 K LED-1630/840
- Reflector with diffuser disk 76 002 152
- Reflector 76 002 155
- Gasket 83 002 317
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
FAQ
- Q: Can this luminaire be installed in both concrete and suspended ceilings?
- A: Yes, this luminaire is suitable for installation in both concrete ceilings and suspended ceilings, both indoors and outdoors.
- Q: What is the recommended wattage for the lamp module and luminaire?
- A: The recommended lamp module connected wattage is 21.5 W and the luminaire connected wattage is 25 W.
- Q: How do I achieve additional protection against overvoltage?
- A: To achieve additional protection against overvoltage, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
References