BEGA 24907K3 Recessed Ceiling Luminaire
Specifications:
- Product Name: Recessed Ceiling Luminaire
- Model Number: 24 907
- Application: Indoor and outdoor installation into concrete ceilings or suspended ceilings
- Light Distribution: Symmetrical wide beam
- Lamp Module Connected Wattage: 13.7 W
- Luminaire Connected Wattage: 15.5 W
- Colour Temperature: 3000 K (LED-1628/830) and 4000 K (LED-1628/840)
- Colour Rendering Index (CRI): > 80
- Module Luminous Flux: 2820 lm – 2890 lm
- Luminaire Luminous Flux: 1980 lm – 2030 lm
- Luminaire Luminous Efficiency: 127.7 lm/W – 131 lm/W
Product Usage Instructions
Installation:
- Insert the luminaire housing into the recessed opening.
- Tighten screws of the claw fastener (torx drive T15) evenly by hand. Do not use an electric screwdriver.
- Ensure the fixing claws swivel onto the inside of the suspended ceiling when tightening the screws to secure the luminaire in place.
- To remove the luminaire, undo the guide screws to allow the fixing claws to swivel back.
Note: Do not remove the desiccant bag from the luminaire housing as it is essential for removing residual moisture.
Recessed ceiling luminaire
Instructions for use
Application
Recessed ceiling luminaire with attached connecting cable for installation
into concrete ceilings or suspended ceilings both indoors and out.
With symmetrical wide beam light distribution.
Product description
-
Luminaire made of aluminium alloy,aluminium and stainless steel
-
BEGA Unidure® coating technology
-
Colour graphite or white Clear safety glass
-
Reflector surface made of pure aluminium
-
Luminaire housing with 2 fixing claws and guide screws
-
Recessed opening ø 160 mm
-
Required installation depth 120 mm
-
Connecting cable X05BQ-F 5 G 1 mm² with free line ends
-
Cable length 0,5 m
-
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1 -
LED power supply unit
220-240 V x 0/50-60 Hz DC 176-275 V -
During DC operation the LED power is reduced to 15 %
-
DALI-controllable
-
Number of DALI addresses: 1
-
Basic insulation is provided between the mains and control cables
-
Safety class I
-
Protection class IP 65
-
Dust-tight and protection against water jets
-
– Conformity mark
-
This product contains light sources of energy
-
efficiency class(es) B
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Lamp
- Module connected wattage 13.7 W
- Luminaire connected wattage 15.5 W
- Rated temperature ta = 25 °C
- Service life criteria 50 000 h / L70
24 907 K3
- Module designation LED-1628/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 2820 lm
- Luminaire luminous flux * 1980 lm
- Luminaire luminous efficiency * 127,7 lm / W
24 907 K4
- Module designation LED-1628/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 2890 lm
- Luminaire luminous flux * 2030 lm
- Luminaire luminous efficiency * 131 lm / W
preliminary data
Lighting technology
Half beam angle 80°
Installation
Luminaire housing must not be installed in heat-insulating material.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
wedge-shaped claws.
A recessed opening of ø 160 mm with a minimum depth of 120 mm is required.
The lateral distance between the luminaire housing and parts of the building
must be at least 50 mm.
The claws grip behind the ceiling cladding. The minimum thickness of the
ceiling cladding is 1 mm.
Ensure that the suspended ceiling and wall surfaces have sufficient load-
bearing capability.
If the thickness is less, and if installation is to be carried out in
plasterboard ceilings, the back of the ceiling cladding must be reinforced in
the region of the claws.
The electrical connection of the free cable end must be carried out with
matching protection class and safety class, relieved of strain, with suitable
connection terminals in a suitable connection box (not included in the scope
of delivery).
Observe the correct configuration of the connecting cable. Make the mains
connection to the brown (L), blue (N) and green-yellow wires ( ).
The control cables are connected via the two DALI-labelled wires white-red (wh-rd) and white-black (wh-bl). If these wires are not assigned, the luminaire will work with full light output.
Insert luminaire housing into the recessed opening. Hand-tighten screws of the
claw fastener (torx drive T15) evenly. Do not use an electric screwdriver!
When tightening the screws, the fixing claws must swivel onto the inside of
the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire
can be removed.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Spares
- Spare glass 14 000 383
- LED power supply unit DEV-0494/350i
- LED module 3000 K LED-1628/830
- LED module 4000 K LED-1628/840
- Reflector with diffuser disk 76 002 150
- Reflector 76 002 154
- Gasket 83 002 316
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
FAQ
Can this luminaire be installed outdoors?
Yes, this luminaire is suitable for installation both indoors and outdoors.
What is the recommended method for fixing the luminaire in a suspended ceiling?
Hand-tighten the screws of the claw fastener evenly using a torx drive T15. Ensure the fixing claws swivel onto the inside of the suspended ceiling during installation.
What is the purpose of the desiccant bag in the luminaire housing?
The desiccant bag is needed to remove residual moisture and should not be removed from the luminaire housing.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>