BEGA 85243K3 Performance Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
50.23 • Technical amendments reserved
85 243
Performance floodlight with minimal diffuse light percentage
IP 65
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories. For a variety of interior
and exterior lighting applications.
BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to a minimised diffuse light percentage and highly efficient glare suppression.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology Colour graphite or silver
Matt safety glass
Internal louvres and polymer lens
BEGA Ultradark Optics®
Louvres and interior surface of anti-glare ring with maximum light-absorbing
ultra-black nano-coating
Rotation range of floodlight 350°
Swivel range -30°/+95°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
- Conformity mark
Wind catching area: 0.053 m²
This product contains light sources of energy efficiency class(es) F
Lighting technology
Symmetrically focused broad spread light distribution with minimal diffuse
light percentage.
Half beam angle 56°
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Please note:
Contact with the inner surface of the luminaire reflector should be avoided in
order to permanently protect the special stray light-minimising properties of
the nano-coating.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm. Secure the screw connection from
loosening on site (if provided with locking screw S , see fig. A ).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B , C ).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection G½ against loosening by tightening the hexagon socket
screws (wrench size 2 mm).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable. Note
correct configuration of the mains supply cable.
The earth conductor is connected at the green-yellow ( ), the phase to the
brown (L), and the neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp
Module connected wattage 55.5 W
Luminaire connected wattage 60 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C
85 243 K3
Module designation LED-1263/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 5985 lm
Luminaire luminous flux 2971 lm
Luminaire luminous efficiency 49,5 lm/W
85 243 K4
Module designation LED-1263/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 6490 lm
Luminaire luminous flux 3222 lm
Luminaire luminous efficiency 53,7 lm/W
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified person using commercially available tools.
Disconnect the system from the power supply. Open the floodlight:
Loosen the locking pin (hexagon socket wrench SW 2.5) on the back of the
floodlight housing. Remove the trim ring along with the safety glass and
reflector by twisting it anti-clockwise.
Please note:
Contact with the inner surfaces of the louvres and luminaire reflector should
be avoided in order to permanently protect the special stray light-minimising
properties of the nano-coating. Grasp the louvres from the outside and lift
them out. Loosen the three mounting screws (Torx drive T20) and lift the lens
holder (with the loosely inserted lenses) upward horizontally out of the
housing.
Replace LED module.
Please follow the installation instructions for the LED module.
Install in reverse order.
When installing the lens holder, make sure that the LED connecting cable is
not pinched. Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71 334 Shield
71 339 Cylindrical shield
70 214 Pole cap for pole top ø48mm
70 248 Pole cap for pole top ø60mm
70 249 Pole cap for pole top ø76mm
70 229 Pole cap for pole top ø82mm
70 245 Mounting box · rectangular
70 280 Tube clamp
70 379 Cross beam
70 889 Lashing strap
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass inside 14 001 666
Trim ring graphite with glass 25 000 285
Trim ring silver with glass 25 000 286
LED power supply unit DEV-0356/1400i
LED module 3000 K LED-1263/930
LED module 4000 K LED-1263/940
Gasket housing 83 001 780
Gasket trim ring 83 002 225
BEGA Gantenbrink-Leuchten KG • Postfach 31 60 • 58689 Menden · info@bega.com • www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>