BEGA 84950 Compact Floodlight
Dimension
Instructions for use
Application
Compact floodlight with mounting box for permanent installations on a wall,
under a ceiling or on a pillar.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Clear safety glass
Reflector surface made of pure aluminium
BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -20°/+90°
Mounting box with 2 fixing holes
ø 6mm · 85mm spacing
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm, max. 5G1.5@
Connecting terminal 2.5@
with plug connection
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Wind catching area: 0.058 m²
Weight: 5.1 kg
This product contains light sources of energy
efficiency class(es) E
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and
remove mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to
terminal (plug connection).
For digital control please use the 2-pole plug connector DA, DA.
In case this connector is not used the luminaire will be operated at full
light output.
Push plug into coupler as far as it will go. Make sure that gasket is
positioned correctly
Place floodlight unit onto the mounting plate as displayed in the sketch, align and screw together firmly
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 7Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only
Lamp
Module connected wattage 72.9 W
Luminaire connected wattage 78 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
84 950K3
Module designation LED-0877/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 9830 lm
Luminaire luminous flux 4987 lm
Luminaire luminous efficiency 63,9 lm/W
84 950K4
Module designation LED-0877/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 9980 lm
Luminaire luminous flux 5063 lm
Luminaire luminous efficiency 64,9 lm/W
Lighting technology
Focused light distribution with minimal diffuse light percentage.
Half beam angle 11°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2mm) in the trim ring.
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71 292 Optical filter flat beam
71282 Shield
71 287 Cylindrical shield
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim frame graphite with glass 25 000 230
Trim frame silver with glass 25 000 231
LED power supply unit DEV-0356/1400i
LED module 3000 K LED-0877/930
LED module 4000 K LED-0877/940
Reflector 75 004 998
Gasket mounting box 83 001 838
Gasket housing 83 002 142
Gasket trim ring 83 002 225