BEGA 84943 Compact Floodlight RGBW Instruction Manual

June 1, 2024
BEGA

BEGA 84943 Compact Floodlight RGBW

 BEGA-84943-Compact-Floodlight-RGBW-product

Specifications:

  • Product Name: Kompaktscheinwerfer RGBW Compact floodlight RGBW Projecteur compact RGBW
  • Material: Aluminium alloy
  • Luminaire Thread Length: 11 mm
  • DALI-controllable: Yes, with 1 DALI address
  • Basic Insulation: Provided between mains and temperature-sensitive components
  • Safety Class: Class I
  • Protection Class: IP 65 (Dust-tight and protection against water jets)
  • Impact Strength: IK07

Product Usage Instructions

Safety Precautions:
Follow national safety regulations for installation and operation. Only qualified electricians should handle installation and commissioning. The manufacturer is not liable for damage due to improper use or installation.

Overvoltage Protection:
Electronic components have overvoltage protection according to DIN EN 61547. For additional protection against transients, consider separate overvoltage protection components.

Installation:
Secure screw connections to prevent loosening. Check the earth conductor connection. Follow the specified torque values for tightening screws and nuts.

Electrical Connection:
Connect matching protection class and safety class, strain-relieved, with suitable connection terminals at the luminaire power supply cable. Ensure correct configuration of mains supply cable and connection of control cables for DALI operation.

Adjustment:
To adjust the floodlight, undo the hexagon socket screw and hexagon nut. Make necessary adjustments and securely tighten them back in place.

Instructions for use

Application

  • Compact floodlights with G½ connecting thread.
  • The floodlight can be screwed on by the customer with any G½ female thread according to ISO 228 or with BEGA accessories.
  • The floodlight can be controlled by DALI colour light control.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Reflector surface made of pure aluminium Rotation range of floodlight 350°
  • Swivel range -20°/+90°
  • Mounting bracket with G½ threaded connection
  • Thread length: 11 mm
  • Connecting cable X05BQ-F 5 G 1 mm²
  • Cable length 1 m
  • BEGA Ultimate Driver Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • Safety mark
  • Conformity mark
  • Wind catching area:  0.027 m²
  • Weight: 2.6 kg

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation
  • Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
  • G½ threaded connection torque = 40 Nm. Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
  • Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

 BEGA-84943-Compact-Floodlight-RGBW-fig- \(2\)

Adjust floodlight:

Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30 mm) and set the desired beam direction.

Torque:

  • Hexagon socket screw = 7 Nm
  • Hexagon nut = 35 Nm
  • Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm) (see sketch B, C).
  • The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
  • Note correct configuration of the mains supply cable.
  • Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1).
  • The connection of the control cables is achieved by means of the both leads marked with DALI.
  • In case these leads are not used the luminaire will be operated at full light output.

Lamp

  • 34,8 W: Module connected wattage
  • 38,6 W: Luminaire connected wattage
  • ta = 25 °C: Rated temperature
  • ta max = 40 °C: Ambient temperature
  • LED-1160/RGBW: Module designation
  • 4000 K: Colour temperature of the white LED 4000 K
  • 2076 lm: Luminaire luminous flux
  • 53,8 lm / W: Luminaire luminous efficiency

Light technique

  • Broad-spread light distribution.
  • Half beam angle 50°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Cleaning · Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.
  • Replacing the LED module
  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply. Open the floodlight:
  • Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim ring.
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

  • 71 281 Shield
  • 71 286 Cylindrical shield
  • 71 291 Optical filter flat beam
  • 71 042 Adapter for installation on a pole 70 214 Pole cap for pole ø 48 mm
  • 70 248 Pole cap for pole ø 60 mm
  • 70 245 Mounting box
  • 70 252 General fastener
  • 70 280 Tube clamp G½
  • 70 283 Screw clamp
  • 70 379 Crossbeam G½
  • 70 889 Tension belt

For the accessories, separate instructions for use can be provided upon request.

Spares

  • 25 000 232: Trim ring graphite with glass
  • 25 000 233: Trim ring silver with glass
  • DEV-0357/200: LED power supply unit
  • LED-1160/RGBW: LED module
  • 76 002 009: Reflector
  • 83 001 027: Gasket housing
  • 83 002 223: Gasket glass retaining ring

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

FAQ

Q: Can the luminaire be controlled remotely?
A: Yes, the luminaire is DALI-controllable with 1 DALI address for remote operation.

Q: What is the protection rating of the luminaire?
A: The luminaire has a protection class of IP 65, making it dust-tight and protected against water jets.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals