BEGA 50 068.4 Wall Luminaire For Indoor Use Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 50 068.4 Wall Luminaire For Indoor
Specifications:
- Lamp Module connected wattage: 19.2 W
- Luminaire connected wattage: 22.5 W
- Rated temperature: 25°C
- Ambient temperature: 45°C
- Module designation: 2x LED-0626/930 + 2x LED-0627/930
- Colour temperature: 3000 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 3210 lm
- Luminaire luminous flux: 2286 lm
- Luminaire luminous efficiency: 101.6 lm / W
Dimension
Product Usage Instructions
Safety Instructions:
The installation and operation of this luminaire must comply with national
safety regulations. Only a qualified electrician should carry out the
installation and commissioning. The manufacturer does not accept liability for
damage due to improper use or installation. Any modifications to the luminaire
should be done by a qualified person.
Overvoltage Protection:
The electronic components in the luminaire are protected against overvoltage
according to DIN EN 61547. For additional protection against transients, it is
recommended to use separate overvoltage protection components available on the
manufacturer’s website.
Replacement Parts:
If replacement parts are needed, refer to the following part numbers:
- Spare glass: 11 002 763 .1R G
- LED power supply unit: DEV-0470/700i
- LED module 3000 K: LED-0627/930
- LED module 4000 K: LED-0627/940
- Gasket glass x2: 83 000 788
Instructions for use
Application
Free radiating wall luminaire · indoor luminaire with hand-blown three-ply
opal glass for a soft and uniform light distribution. The elongated design of
this wall luminaire particulary provides suitability for installation on
pillars, columns and for the front surface of walls, as well as for recesses
or profiles. The luminaire may be installed horizontally or vertically.
Product Description
- Metal luminaire housing, finish Colour velvet brass
- Hand-blown opal glass
- The electrical equipment can be hinged with 2 mounting holes ø 6 mm
- Distance apart 300 mm
- Jointing sleeve with cable entry for mains supply cable up to ø 14 mm, max. 5 x 1.5°
- Connecting terminals 2.5°
- Earth conductor terminal
- Complies with flicker requirements in accordance with IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit 220-240 V /50-60 Hz DC 176-276 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK03
- Protection against mechanical impacts < 0.35 joule
- Safety mark
- Conformity mark
- Weight: 3.0 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Installation
- LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo hexagon socket (wrench size 5) in the locking cap and remove it.
- The opal glass can now be hinged together with the electrical equipment to the front.
- Remove opal glass.
- Note the position of application of the luminaire »arrow down«.
- Drill mounting holes into the mounting surface- spacing 300 mm and turn in enclosed or suitable fixing screws.
- For the electrical connection undo the screw connection at the line connector and remove terminal block.
- Make earth conductor connection and electrical connection.
- Make a connection of the phase with the L marked, the neutral wire at the N marked and earth conductor at the PE marked connecting terminal.
- For digital actuation please use the two connecting terminals DA. If these terminals are not assigned, the luminaire will work with full light output.
- Bolt together both screw cable glands firmly.
- Hook luminaire into the fixing screws and tighten.
- Slide opal glass over the lamp and fasten with the locking cap.
- Make sure that the gaskets are positioned correctly.
Lamp
- Module connected wattage 19.2 W
- Luminaire connected wattage 22.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
50 068.4 K3
- Module designation 2x LED-0626/930 + 2x LED-0627/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3210 lm
- Luminaire luminous flux 2286 lm
- Luminaire luminous efficiency 101,6 lm / W
50 068.4 K4
- Module designation 2x LED-0626/940 + 2x LED-0627/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 3350 lm
- Luminaire luminous flux 2386 lm
- Luminaire luminous efficiency 106 lm / W
Cleaning And Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt.
- The defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- The defective glass must be replaced.
- Close the luminaire.
Spares
- 11 002763.1RG: LED power supply unit
- DEV-0470/700i: LED module 3000 K
- LED-0627/930: LED module 3000 K
- LED-0627/940: LED module 3000 K
- LED-0626/930: LED module 3000 K
- LED-0626/940: LED module 3000 K
- 83 000 788: Gasket glass 2x
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
FAQ
Q: Can I install this luminaire myself?
A: No, installation and commissioning should only be done by a qualified
electrician to ensure safety and proper functionality.
Q: Where can I find overvoltage protection components?
A: Overvoltage protection components can be found on the manufacturer’s
website at www.bega.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>