Inditech Online Parallel Lop 75×275 Dot Touch- 24V Wall Mount User Manual
- June 9, 2024
 - Inditech Online
 
Table of Contents
USER MANUAL
TYPE OF MODEL:
- PARALLEL LOP 75×275 DOT TOUCH- 24V
 - PARALLEL LOP 75×275 DOT TOUCH – 12V
 

PLEASE CHECK THE ONLINE PROCEDURE FOR CUSTOMIZATION OF LOGO
COMPATIBLE FOR ARKEL PARA CONTROL PANEL
BEAUTIFUL SLIM DESIGN WITH SS FRAME AND STUNNING SHINY ACYLIC FASCIA
Note: This document is common for various models. Kindly verify the model you procured. Read the document as per the model you procured.
FEATURES/ SPECIFICATIONS:
- Mount Type- Wall Mount
 - Fascia- Black/White Color
 - Input Supply- 12/24V
 - Parallel Interface
 - Support- Up to G+7 Floors
 - Display Type- RED Dot Matrix
 - Buttons – Capacitive Touch
 - Size (WHT)-75x275x18MM
 - Reliable
 - Easy to use
 - Durable
 
CONNECTION DETAILS:

Note: For connection details refer below page.
A DISPLAY CONNECTION DETAILS:
| Sr. No. | Wire Color | Connection Details (J1) (12 Pin Relimate Connector) | 
|---|---|---|
| 1 | BLACK | 12V | 
| 2 | BROWN | GND | 
| 3 | RED | A | 
| 4 | ORANGE | B | 
| 5 | YELLOW | C | 
| 6 | GREEN | D | 
| 7 | BLUE | E | 
| 8 | VIOLET | F | 
| 9 | GRAY | G | 
| 10 | WHITE | UP (ARROW) | 
| 11 | BLACK | DOWN (ARROW) | 
| 12 | BROWN | NC (No Connection) | 
B SPECIAL INPUT CONNECTION DETAILS:
| Sr. No. | Wire Color | Connection Details (J3) (4 Pin Relimate Connector) | 
|---|---|---|
| 1 | BLACK | IN1 (To Display digits 10 to 19) | 
| 2 | BROWN | IN2 (To Display digits 20 to 23) | 
| 3 | RED | OL (For Overload) | 
| 4 | ORANGE | M (For Maintenance) | 
C TOUCH BUTTON CONNECTION DETAILS:

INSTALLATION STEPS:
Note: Installation and Commissioning of the LOP is to be done by
Authorized, Trained technician of Elevator Company.
Following are the steps to be taken for the installation of this panel.
- Remove the back plate of LOP
 - Mount the back plate of LOP on the wall
 - Do the connections as per below Connection Diagram
 - Fix the LOP on back plate
 - Do the calibration as per process given in calibration process
 
MOUNTING DETAILS:

CALIBRATION PROCESS:
- Give segment which is set to for floor.
 - Press S1 and S2 both keys then display shows ‘- – ‘then release both the keys.
 - When’- -‘ symbol stop blinking, press S1 and S2 for increment & decrement.
 - After pressing S1 & S2 keys for increment and decrement it shows digits Which we have to set.
 - After showing display which is we have to set, then release the key after sometime.
 - Display will blink and shows – – means calibration is saved & it will display Saved floor.
 - Repeat same procedure for next floor calibration.
 
CALIBRATION RESET PROCESS:
- If we want to display only normal 7 segment, then no need to calibrate.
 - Short the pin No. 1 & 2 of J4 berg strip for 10 second.
 - After completion of 10 second display is shows ‘FR’ it means process is Completed and program is in normal 7 segment mode.
 - Give 7 segments to the connector J1, display will show floor.
 