STRAIGHT TO MAINS TWIN SPIKE POLE LIGHT 230V
Instructions
INSTALLATION
- Remove the protective cup from the bottom of the pole.
- Hammer a pole into the ground using a rubber/ wooden mallet. Alternatively, a standard hammer can be used, but the top of the pole must be protected e.g. by placing a piece of wood on top of the pole before hitting it with a hammer. Be sure to check for any pipes, cables, etc. that may be damaged by the installation of this product.
- Connect a main supply to each product.
Note: In wet or damp areas, suitable IP-rated connectors or junction boxes must be used.
INSTALLATION DATA
- This unit must be wired by a qualified electrician or a suitable competent person.
- This fitting must be earthed.
- Flying lead; Brown = Live, Blue = Neutral, Green/Yellow = Earth.
- Rated voltage 220-240V AC.
- Input power 11.4W
- Input current 0.06A.
- Inrush current 120A, 0.037ms.