seitron N.VO Combustion Analyzer User Guide
- September 5, 2024
- seitron
Table of Contents
seitron N.VO Combustion Analyzer
Specifications
- Product: Combustion Analyzer
- Model: Novo Analyzer
- Compliance: EN 50379-1, EN 50379-2
Product Usage Instructions
Power On/Power Off
- INSTRUMENT CONDITION OFF (powered off)
- ON (powered on)
Action
Press and hold the key indicated by the arrow for a long time (> 3sec.)
Function
- The instrument powers on* and starts the automatic auto-zero phase.
- The instrument turns off after completing the cleaning cycle for the set time.
- At the first start, the instrument will guide the user step by step to the first configuration.
Complete Combustion Analysis Menu
- Performs the complete combustion analysis; moreover, it accesses the analysis configuration menu; the user can set every single parameter of the instrument to perform the combustion analysis.
Operator Menu
- Enters the Operator menu; it is possible to select the name of the operator performing the analysis, which will be printed on the analysis report.
Measurements Menu
- Accesses the Measurements menu; the user accesses all the accessory measurements that the instrument can perform.
FAQ
Q: How do I access the full manual for detailed information on the PRO analysis screen?
A: You can download the complete user and maintenance manual from Seitron’s website at www.seitron.com.
Q: What are the recommended connections for different measures using this analyzer?
A: The suggested connections are used for measures such as O2, Gas: CO, NO, SO2, CxHy, NO2, H2, CO2, NH3, efficiency calculation, combustion analysis, and simultaneous measurement of gas pressure at the burner.
COMBUSTION ANALYSIS
FEATURES
- Flue gas analysis & Real-time data graph display
- Calculating stack heat loss and efficiency
- Ambient CO measurement
- Measuring differential pressure
- Draft measurement
- Pressure measurement in the gas supply pipe
- Tightness test
- Black smoke test and average value calculation
- QR code display visualization in order to download the data of the acquired measurements
- Ticket printing with the measurements data using a built-in printer (if provided) or using the optional Bluetooth® printer.
- WARNING! The magnets in the back of the instrument can damage credit cards, hard drives, mechanical watches, pacemakers, defibrillators, and other devices proven sensitive to magnetic fields.
- It is recommended to keep the instrument at a distance of at least 25cm away from these devices.
OPERATION
- Between these inputs and the smoke probe, there can be up to a maximum of three extension cords, with a total length of 3 meters each.
- The suggested connections are used for the following measures: O2
- Gas : CO – NO – SO2 – CxHy – NO2 – H2 – CO2 – NH3
- Efficiency calculation
- Combustion analysis
- Simultaneous measurement of gas pressure at the burner
POWER ON / POWER OFF
INSTRUMENT CONDITION | ACTION | FUNCTION |
---|---|---|
**O** FF (powered off) | Press and hold the key indicated by the arrow for | |
a long time (> 3sec.) | The instrument powers on* and starts the automatic |
auto-zero phase
ON (powered on)| Press and hold the key indicated by the arrow for a long
time (> 3sec.)| The instrument turns off after completing the cleaning cycle
for the set time.
MAIN MENUS
1| Performs the complete combustion analysis; moreover, it accesses
the analysis configuration menu; the user can set every single parameter of
the instrument to perform the combustion analysis.
---|---
2| Enters the Operator menu; it is possible to select
the name of the operator performing the analysis, which will be printed on the
analysis report.
3| Access the Measurements menu; the user accesses all the accessory
measurements that the instrument can perform.
4| Access the configuration menu; the user can set the
different reference parameters of the instrument.
5| Accesses the Print menu.
6| Access the Archive menu; the user displays the
measurements stored in the memory.
BLUETOOTH PRINTER ASSOCIATION PAIRING
In order to pair the Bluetooth® printer with the instrument, access the “Pairing” parameter accessible via the Print menu and proceed as follows.
1 | Once in the Print menu, enable the external printer. |
---|---|
2 | Turn on the Bluetooth® printer to be paired with the instrument. |
3 | Access the Pairing BT parameter. |
4 | Wait 10 s and select the line corresponding to the MAC address of the |
Bluetooth® printer to pair.
5| The instrument automatically associates the selected printer. The
analyzer does not give any message.
6| Return to the previous screen.
ATTENTION!
- It is possible to pair multiple Bluetooth® printers with the instrument.
- If you have multiple Bluetooth® printers associated with the instrument, you must select the printer that will be used to print the tickets.
- Seitron respects nature and the environment and therefore provides this quick user guide for the Novo analyzer.
- You can download the PC software “CHEMIST SMART ANALYSIS” and the complete user and maintenance manual from our website www.seitron.com.
- Respect your environment: think before printing the full manual on paper.
- Seitron S.p.A. a socio unico
- Via del Commercio, 9/11 – 36065 – MUSSOLENTE (VI) ITALY
- Tel. 0424.567842 –info@seitron.it – www.seitron.com